background image

- If you keep pressing CH button for a while under

channel setting mode, the words, 

CH ALL ON

is

showed shortly on the indicator. After then, CH 1~4

are all changed to ON mode and it moves to

channel output setting screen again. 

- If you keep pressing CH button for a while when all

channel is set as ON mode, the words, 

CH ALL

OFF

is showed shortly on the indicator. After then

CH1~4 are all changed to OFF mode and it moves

to channel output setting screen again.

5) Press ENTER button after channel setting, then the

setting is saved and over.

6) Reserved data is played on the set time.

- If you reserve the same time with already saved

time, former data is removed and latter data is

saved.

3. MELODY SETTING

- To play the saved sound source

in this unit on desired time.

- MELODY

1) Keep pressing the MELODY button, then LED

flickers. Ready to set from now.

2) Same way with voice setting for other settings.

- Track setting should be entered from 1 to 15.

Melody offered by this unit is limited to 15 tracks. 

Over than 15 tracks is not allowed.

3) Start to play with reserved data on the set time.

4. MELODY PLAY

- play the sound which was saved in

this unit by selecting the desired track and channel.

1) Keep pressing the track button for a while, then

setting starts.

2) Enter the track which will be played with numeric

button and press ENTER button. After that press CH

button, then it is changed to CHANNEL mode.

3) After selecting the channel, if pressing the ENTER

button, selected track is played. When playing is

over, it stops automatically.

This function is not available during

MELODY/VOICE playing.

5. AC SETTING

Function to ON/OFF the AC OUTLET and REMOTE

OUTPUT in desired time.

AC OUTLET and REMOTE OUTPUT are operated at

the same time.

1) Keep pressing AC button, then LED flickers. Ready

to set from now.

2) Way to set the reservation time is same with

VOICE/MELODY setting function.

3) ON/OFF setting of AC OUTLET is started by

pressing CH button. After that, each time pressing

CH button, ON/OFF is changed.

4) Press ENTER button, then setting is saved.

- It is designed to operate AC OUTLET and

REMOTE OUTPUT during MELODY/VOICE

playing, and when playing is over, operating AC

OUTLET and REMOTE OUTPUT is also over.

- If reserving AC OUTLET with the same time of

MELODY/VOICE reservation time, even when

melody is over, AC OUTLET and REMOTE

OUTPUT keep out.

6. CHECKING THE RESERVATION DATA

When voice, melody, and AC data were reserved, able

to check as below, and if there was no memory,

NO

PROGRAM TIMER

IPT-8254   

9

Содержание IPT-8254

Страница 1: ......

Страница 2: ...npacking 3 Before Use 3 Safety Instruction 4 Operation 5 Features 5 Front Panel 6 Rear Panel 7 Detail Operating Method 8 Precaution to Install RACK 12 Rack Connection 12 Block Diagram 13 Specification...

Страница 3: ...them If you ever need to return the unit to INKEL PA or an authorized service center you should use only the original factory packing Welcome WARNING TO PREVENT FIRE OF ELECTRIC SHOCK HAZARD DO NOT EX...

Страница 4: ...to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the...

Страница 5: ...up even though AC power turns off with current time set There is no need of re adjusting time ever though AC power is applied SOLUTION IN POWER FAILURE Used Flash Memory to prevent the loss of date c...

Страница 6: ...by pressing this button 9 DELETE BUTTON To delete the reserved data 10 COPY BUTTON To copy the reserved date to other dates 11 CHANNEL BUTTON To select the melody voice reservation setting and output...

Страница 7: ...intended to receive a signal from the output of the IVF 8201 VOICE FILE 5 CHANNEL INPUT JACK These are the input jacks for channel 1 through 4 6 DC INPUT OUTPUT DC power input and output terminal its...

Страница 8: ...l be changed to STAND BY mode 7 After setting completion LED will be illuminated relevant weekly on date indicator 2 VOICE SETTING To play saved sound source in IVF 8201 VOICE FILE at the desired time...

Страница 9: ...lecting the desired track and channel 1 Keep pressing the track button for a while then setting starts 2 Enter the track which will be played with numeric button and press ENTER button After that pres...

Страница 10: ...is same with above 3 Press CANCEL button then it returns to STAND BY mode 7 MODIFY Function to change the VOICE MEDOLY AC reservation data 1 Select the data which should be changed with DOWN UP butto...

Страница 11: ...saved and over 4 Available to set range of 1 to 20 seconds and the basic setting is 10 seconds 11 ADJUST TIME CALIBRATION Use this button when time is fast or slow 1 Keep pressing TIME button for a wh...

Страница 12: ...fter checking the power capacity by our agency Be sure to check the power capacity before use Turn off the RACK POWER totally Use AC and DC power properly according to the power source of other device...

Страница 13: ...PROGRAM TIMER IPT 8254 13 Block Diagram...

Страница 14: ...e 15 settings Total 240 second Operation Temperature 10 40 Storage Temperature 20 60 GENERAL Power Source AC 100V 120V 220V 240V 50 60Hz DC 24V Supplied AC main transformer depends on country requirem...

Страница 15: ...m WARRANTY INFORMATION Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating t...

Страница 16: ......

Отзывы: