9. DELETE

Function to delete the reserved data.

1) Select the data which will be deleted among of

reserved data, and press DELETE button.

- If pressing DELETE button for a while, data deletion

screen is showed as below.

- If pressing DELETE button, all data of selected date

is eliminated.

2) Deletion of reservation data per day is shifted to

relevant mode by pressing DELETE button in

STAND-BY mode.

- Select the day with DAY button or UP/DOWN

button. 

- Order of DAY button is MON 

TUE 

WED 

THU 

FRI 

SAT 

SUN 

ALL.

- DELEATE ALL erase all reserved data.

3) Press ENTER button, then all data of selected day is

eliminated.

10. AC OUTPUT TIME CONTROL

Function to release AC OUTLET and REMOTE

OUTPUT per setting time in advance before reserved

broadcasting.

With this function, when reserved broadcasting is out

without delay by operating connected unit in advance.

1) Keep pressing AC OUTLET button in STAND-BY

mode, then able to control AC OUTPUT time.

2) Enter AC power output time with numeric button.

3) Press ENTER button, then it is saved and over.

4) Available to set range of 1 to 20 seconds, and the

basic setting is 10 seconds.

11. ADJUST TIME CALIBRATION

Use this button when time is fast or slow.

1) Keep pressing TIME button for a while in STAND-BY

mode, then setting is available from now.

2) Enter setting data with numeric button.

- Available to set range from - 30 to + 30 and the

basic setting is - 8.

- Time is adjusted for 0.2 seconds per a day for each

stage.

3) +/- in front of number can be changed with TIME

button.(+ is to be faster and - is to be slower)

4) Press ENTER button, then it is saved and over.

12. KEY LOCK

1) Function to protect reserved data. Keep pressing

ENTER button for a while, the word, 

KEY LOCK

is

showed on the screen shortly, and entry of all

function buttons is locked.

2) Press ENTER button again, the word, 

KEY

UNLOCK

is showed on the screen shortly, and

entry of all function buttons is available.

13. OTHERS

1) Able to ON/OFF the AC power output with AC

OUTLET button.

- When you want AC power output, press AC

OUTLET button to turn on the LED.

2) When LED on OUTPUT button is off, if MELODY is

played, it does not come out. If you want sounding,

press OUTPUT button to turn on the LED.

- VOICE reserved broadcasting output always comes

out no matter what button is placed.

Содержание IPT-8254

Страница 1: ......

Страница 2: ...npacking 3 Before Use 3 Safety Instruction 4 Operation 5 Features 5 Front Panel 6 Rear Panel 7 Detail Operating Method 8 Precaution to Install RACK 12 Rack Connection 12 Block Diagram 13 Specification...

Страница 3: ...them If you ever need to return the unit to INKEL PA or an authorized service center you should use only the original factory packing Welcome WARNING TO PREVENT FIRE OF ELECTRIC SHOCK HAZARD DO NOT EX...

Страница 4: ...to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the...

Страница 5: ...up even though AC power turns off with current time set There is no need of re adjusting time ever though AC power is applied SOLUTION IN POWER FAILURE Used Flash Memory to prevent the loss of date c...

Страница 6: ...by pressing this button 9 DELETE BUTTON To delete the reserved data 10 COPY BUTTON To copy the reserved date to other dates 11 CHANNEL BUTTON To select the melody voice reservation setting and output...

Страница 7: ...intended to receive a signal from the output of the IVF 8201 VOICE FILE 5 CHANNEL INPUT JACK These are the input jacks for channel 1 through 4 6 DC INPUT OUTPUT DC power input and output terminal its...

Страница 8: ...l be changed to STAND BY mode 7 After setting completion LED will be illuminated relevant weekly on date indicator 2 VOICE SETTING To play saved sound source in IVF 8201 VOICE FILE at the desired time...

Страница 9: ...lecting the desired track and channel 1 Keep pressing the track button for a while then setting starts 2 Enter the track which will be played with numeric button and press ENTER button After that pres...

Страница 10: ...is same with above 3 Press CANCEL button then it returns to STAND BY mode 7 MODIFY Function to change the VOICE MEDOLY AC reservation data 1 Select the data which should be changed with DOWN UP butto...

Страница 11: ...saved and over 4 Available to set range of 1 to 20 seconds and the basic setting is 10 seconds 11 ADJUST TIME CALIBRATION Use this button when time is fast or slow 1 Keep pressing TIME button for a wh...

Страница 12: ...fter checking the power capacity by our agency Be sure to check the power capacity before use Turn off the RACK POWER totally Use AC and DC power properly according to the power source of other device...

Страница 13: ...PROGRAM TIMER IPT 8254 13 Block Diagram...

Страница 14: ...e 15 settings Total 240 second Operation Temperature 10 40 Storage Temperature 20 60 GENERAL Power Source AC 100V 120V 220V 240V 50 60Hz DC 24V Supplied AC main transformer depends on country requirem...

Страница 15: ...m WARRANTY INFORMATION Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating t...

Страница 16: ......

Отзывы: