background image

[email protected]

www.inkbird.com

4/F E, Bldg 713, Pengji Industrial Zone,

Liantang St, Luohu Dist, Shenzhen, China.

INKBIRD TECH.C.L

V1.0

Содержание IHT-2PB

Страница 1: ...IHT 2PB Bluetooth Digital Food Thermometer With 2 External Probes ...

Страница 2: ...tant Notes Warning 24 09 Product Warranty 25 10 FCC Requirement 25 11 Meat Temperature Doneness Chart 27 Free App Download Bluetooth Connection 06 Operation Instructions 07 App Operating Functions Menu Instruction Parameter Setting Guide Operating Functions Of The Built In Probe unplugging the external probes BBQ Functions plugging the external probes ...

Страница 3: ...ital Food Thermometer Product Model IHT 2PB 3 stainless steel probes for temperature measuring Heat resistant waterproof probe cables Temperature range of probes 50 0 300 58 0 572 Measurement accuracy 0 5 1 0 Readout time Built in Probe 2 seconds Support Bluetooth connection Auto off sleep mode Clear backlit LCD Screen HOLD function to lock the measured temperature on the LCD screen ALARM function...

Страница 4: ...03 Product Diagram P1 P2 LCD Screen Backlight HOLD UP Button SET Button POWER DOWN Button 1 5 6 7 8 2 3 4 P 1 P 2 8 Probe 1 2 Sockets Battery Charge Port Built in Probe Magnetic Back 02 ...

Страница 5: ...ng IOS 11 or above to download the app Your Android devices must be running Android 5 0 or above to download the app Press the button to turn on Bluetooth press the button again to turn off Bluetooth You would see the Bluetooth icon flashing at a frequency of 2Hz which means the application is searching to connect When the Bluetooth icon is off Bluetooth is disconnected 04 Connection Free App Down...

Страница 6: ...Open BBQGO Pro App the installed application on your phone B Click to add a device C 04 ...

Страница 7: ...Choose IHT 2PB D Make sure the Bluetooth icon on IHT 2PB is flashing at a frequency of 2Hz and then click Next Step E 05 ...

Страница 8: ...turn off the device In setting mode press the button to decrease the value of parameters long press the button to quickly decrease the value of parameters In normal mode press the button to lock or unlock the value of current temperature press and hold the button for 3 seconds to switch the display of 3 channels In setting mode press the button to increase the value of parameters long press the bu...

Страница 9: ... Operation Interface 06 Operation Instructions App Operating Functions 07 ...

Страница 10: ... Setting Menu 08 ...

Страница 11: ... More Settings 09 ...

Страница 12: ...0 572 Alarm value for the built in probe 77 0 170 Temperature calibration for the built in probe 4 9 4 9 9 9 9 9 0 0 0 0 ON or OFF ON Alarm function for the external probe1 50 0 300 58 0 572 Alarm value for the external probe1 77 0 170 Temperature calibration for the external probe1 4 9 4 9 9 9 9 9 0 0 0 0 ON or OFF ON Alarm function for the external probe2 50 0 300 58 0 572 Alarm value for the ex...

Страница 13: ...tically saved if there is no operation in 30 seconds Step 1 press and hold button for 2 seconds to enter the menu for function setting then press the button to choose BEE function Step 2 press or button to choose ON or OFF Step 2 press or button to choose or NOTE All parameters will be restored to their default values once you change the temperature unit Temperature Display Unit of Key Sound Param...

Страница 14: ...o increase or decrease the value long press or button to quickly increase or decrease the value The active time of the backlight is adjustable from 5 to 60 seconds Step 3 press and hold button for 2 seconds to quit and save changes All changes will be automatically saved if there is no operation in 30 seconds Step 1 press and hold button for 2 seconds to enter the menu for function setting then pr...

Страница 15: ... choose TS function Step 1 press and hold button for 2 seconds to enter the menu for function setting then press the button to choose CA function Step 2 press or button to increase or decrease the value long press or to quickly increase or decrease the value Step 3 press and hold button for 2 seconds to quit and save changes All changes will be automatically saved if there is no operation in 30 se...

Страница 16: ...rature is 75 5 the screen displays 75 8 after setting the CA value as 0 3 Step 1 press and hold button for 2 seconds to enter the menu for function setting then press the button to choose ALM2 function Step 2 press or button to choose ON or OFF Step 3 press and hold button for 2 seconds to quit and save changes All changes will be automatically saved if there is no operation in 30 seconds Alarm Fu...

Страница 17: ...hanges will be automatically saved if there is no operation in 30 seconds Step 1 press and hold button for 2 seconds to enter the menu for function setting then press the button to choose CA2 function Step 2 press or button to increase or decrease the value long press or to quickly increase or decrease the value Step 3 press and hold button for 2 seconds to quit and save changes All changes will b...

Страница 18: ... quit and save changes All changes will be automatically saved if there is no operation in 30 seconds Step 1 press and hold button for 2 seconds to enter the menu for function setting then press the button to choose TS2 function When the current temperature is 75 5 the screen displays 75 8 after setting the CA value as 0 3 Alarm Function for P2 the External Probe 2 Alarm Value Setting for P2 the E...

Страница 19: ...0 seconds Step 1 press and hold button for 2 seconds to enter the menu for function setting then press the button to choose CA2 function Step 2 press or button to increase or decrease the value long press or to quickly increase or decrease the value Step 3 press and hold button for 2 seconds to quit and save changes All changes will be automatically saved if there is no operation in 30 seconds Tem...

Страница 20: ...LM ON the alarm function is on the screen displays SET TEMP and the alarm value of the probe When ALM OFF the alarm function is off the screen displays SET TEMP and When the current temperature is 75 5 the screen displays 75 8 after setting the CA value as 0 3 Operating Functions Of The Built In Probe unplugging the external probes Screen Display 18 ...

Страница 21: ...s the device will automatically return to work When you set ALM as OFF the alarm function is off and the screen only displays the current measured tempera ture When you set ALM as ON the alarm function is on and the screen displays the alarm value TS and the current measured temperature A symbol will appear on the screen if the current temperature reaches the alarm value TS Meanwhile the device wi...

Страница 22: ...y when the probe detects a temperature change When you plug the external probe P1 the P1 probe is the current channel The LCD screen displays data of the current channel in priority P1 symbol appears on the screen When ALM1 ON the alarm function of P1 probe is on the screen displays SET TEMP and the alarm value of P1 probe When ALM1 OFF the alarm function of P1 probe is off the screen displays SET...

Страница 23: ... ALM2 ON the alarm function of P2 probe is on the screen displays SET TEMP and the alarm value of P2probe When ALM2 OFF the alarm function of P2 probe is off the screen displays SET TEMP and When you plug both external probes simultaneously both external probes are current channels The LCD screen alternately displays data of both external probes at a frequency of 0 5Hz 21 ...

Страница 24: ...tton to cancel the alarm The alarm will automatically stop if the temperature goes lower than the alarm value When you use the external probes please 1 Place the external probes inside the oven if you use an oven 2 Make sure the external probes are inserted into the thickest center part of the meat Avoid bones and fat 3 Make sure the probe cables stay away from extrusion and fire 4 Place or hang t...

Страница 25: ...splay problem is still unsolved or the screen displays Er1 please contact INKBIRD Q3 What can you do if the screen do not display any value about P2 after inserting an external probe into theP2 jack Answer Please do as follows unplug the external probe insert it into the P2 jack again with steady force rotate the jack plug to make sure that it has good Press and hold button for 3 seconds to switch...

Страница 26: ...dren to avoid possible harm Please clean and air dry the probes after use Please do not immerse the thermometer in the water though it can be rinsed with water Please do not clean the jack plug of each probe with water or it may cause bad contact Please do not use the stainless steel probes in 08 Important Notes Warning contact with the P2 jack If the display problem is still unsolved or the scree...

Страница 27: ... discretion of INKBIRD be either repaired or replaced without charge changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any...

Страница 28: ...termined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tec...

Страница 29: ...ne Beef 49 120 54 130 60 140 66 150 77 170 49 120 54 130 60 140 66 150 77 170 49 120 54 130 60 140 66 150 77 170 63 145 74 165 74 165 63 145 75 167 102 110 216 230 52 80 126 176 20 30 68 86 Veal Lamb Pork Chicken Turkey Fish Hambur ger BBQ Smoke Hot Smoke Cold Smoke 27 ...

Страница 30: ......

Страница 31: ...Support inkbird com www inkbird com 4 F E Bldg 713 Pengji Industrial Zone Liantang St Luohu Dist Shenzhen China INKBIRD TECH C L V1 0 ...

Страница 32: ...80 160mm 骑马订 ...

Отзывы: