background image

VerifiedAlarmsNetwork

 How it works......

Modern network enabled cameras (see http://www.verifiedalarms.com/ camerassupported.html) can be used 

as a standalone form of surveillance for a home or a small business or it could be linked to a professionally 

installed intruder or fire alarm system to give a verification of the nature of the alarm..... Is there really an 

intruder in the property or is the alarm caused by some other action, for example the weather, lightning, 

thunder etc. Or has an animal made its way into the building? Or is it a member of staff who has incorrectly 

operated the alarm?

This flexibility that these cameras provide leads to issues with bandwidth and delivery.

Because of the size of the images and the potentially high numbers of images sent it is necessary to have the 

remote location on a connection with a huge incoming data “pipe”. This way images can be streamed easily 

and quickly into receiving servers.

VerifiedAlarms operates country servers located currently in the UK, Europe and USA. Other country servers 

will be added as time progresses (if you are interested in a franchise please contact us at 

[email protected]).

These servers are manufactured by Initsys and they, in turn, control a bank of Mass Video Storage 

Devices(MVSD). Each server can control up to a Petabyte of MVSD.

New MVSD are added from time to time to keep the available space well above the expected demand from 

subscribers. And we keep our bandwidth controlled so that when you need to send a vital alarm you can.

As soon as an image arrives at a MVSD its location, size and other network information is relayed to the 

country server and that data is used to decide the next course of action. It could be that you wish to be 

informed by SMS message or email or indeed you could subscribe to one of our partner commercial Alarm 

Receiving Stations (ARC) to link the alarm images to actual data from an on-site intruder/fire or other alarm. 

The ARC operators then have images to verify that the alarm is true or false.

Of course the images remain on the server until they are overwritten or are deleted by the owner. 

The owner can view these at any time by simply logging into the country server and selecting the images. 

This is all achieved through a standard security enabled browser.

Alarms are handled by Initsys Merlin2DotZero the 3

rd

 dimension in alarm handling, incorporating audio and 

video to alarm data.

Other systems may exist that allow remote transmission of CCTV, but you need to ask yourself....

“Is it a professional service? Does it guarantee delivery of my alarm to the alarm receiving centre? And are 

my cameras protected from unauthorised viewing by just anyone at any time?”

Содержание Vid1VideoServer

Страница 1: ...Installation Manual Version 1 5 October 2007 ENGLISH www initsys co uk How much clearer does it need to be Vid1Videoserver ...

Страница 2: ...andard 1vpp CCTV video output to a format that is compatible with the VerifiedAlarms network It also has a digital input and output that enable the device to signal alarms and switch Detailed Safety Instructions 1 Read these instructions carefully 2 Keep these instructions 3 Heed all warnings ...

Страница 3: ...ge Devices MVSD Each server can control up to a Petabyte of MVSD New MVSD are added from time to time to keep the available space well above the expected demand from subscribers And we keep our bandwidth controlled so that when you need to send a vital alarm you can As soon as an image arrives at a MVSD its location size and other network information is relayed to the country server and that data ...

Страница 4: ...an use our Bulletin Board address at the end of the document No matter how you use our servers I hope you have a good experience if not send me a mail my address is cberry Initsys co uk Thank you very much Christopher Berry cberry Initsys co uk Contents 1 Description 4 2 Hardware Overview 5 3 Initial Programming 6 3 1 Image 6 3 2 Audio 7 3 3 System 7 3 4 Network 8 3 5 Event 8 5 Example Schematic 1...

Страница 5: ...r and Network Cameras Units that are not directly supported can be interfaced using the Vid1videoserver blackbox The following document explains how to connect to the VerifiedAlarms network and ultimately to an off site event monitoring by a control room 2 Hardware Overview Two models exist a standard wired unit and by special order a wireless version 5 ...

Страница 6: ...from our BBS use ARP Ping or login to the device s default IP address and change from the set up Open the device by typing the URL in the Browser You must use Internet Explorer with the Vid1VideoServer You will need to enter the Username and Password defaults are Live User user user00 Admin User admin admin00 First time login will require the Active X download from the unit ensure your Pop up Bloc...

Страница 7: ...n MPEG4 and MJPEG mode and has two compression options for each mode The device is compatible with both Initsys VerifiedAlarms iRecord and Merlin products 3 2 Audio Set the audio up as follows You can test the audio by clicking in the microphone option on the front page and speaking into a connected microphone on the connected computer 7 ...

Страница 8: ...d be changed from the default settings These need to entered into the VerifiedAlarms Connections and the Monitoring Station informed Restart is a soft boot Factory Default is as is said you will loose all information if this is selected IP allowed addresses can be entered here to increase security this will ensure that the device will only respond to incoming transmission from the alarm receiving ...

Страница 9: ...port in the WAN router points to the video server 3 5 Event Tick the event enable option Choose the Primary Motion JPEG option Adjust the frame rate we recommend 2 to 4 fps For connection to a DVR NVR or any other device being used to trigger from a change of contact state then tick the Digital Input option Digital Motion sensing can be used for internal applications Do not tick Video Loss the con...

Страница 10: ...fiedAlarms Save File Name please call this image Username This is the Admin Username to VerifiedAlarms Password This is the Admin Password to VerifiedAlarms Select the number of Pre and Post alarm images For example we have fps at 4 and pre and post images set to 8 we will transmit 2 second before the event and 2 seconds after the event with a total of 16 images 10 16 January 2008 ...

Страница 11: ...Vid1VideoServer 4 Example Schematic 11 ...

Страница 12: ...Vid1VideoServer 5 Relay Control 6 Specifications 6 1 Pin Connections 6 2 Led Indications 12 16 January 2008 ...

Страница 13: ...ng IP address arp s 192 168 1 200 00 30 ba bf 56 10 ping 192 168 1 200 UNIX Linux Mac syntax UNIX Linux MAC example arp s IP address MAC address temp ping IP address arp s 192 168 1 200 00 30 ba bf 56 10 temp Check if the network cable is connected to the server and start restart the server by disconnecting and reconnecting the power line Close the Command Prompt when you see Reply from 192 168 1 ...

Страница 14: ...sormatic Ultra III Sensormatic Ultra V Sensormatic Ultra VII JVC TKC 676 Ernitec ICU PTZ S 51PA Ernitec Orion 361 312 Kalatel KTD 312 Video Controls Ltd VCL Orbiter Microsphere VCL Orbiter Gold Videor F2 Videor EDC 141E Videor EDC 142E Videor EDC 143E 7 0 EULA and Licence The VerifiedAlarmsNetwork and Initsys systems is covered by an End User Licence Agreement that governs warranty limitation of l...

Страница 15: ...Server Contact information This document Vid1VideoServer www Initsys co uk 44 1530 262100 44 1530 260782 Unit 6 Marquis Court Marquis Road Rawdon Moira DE12 6EJ 15 Illustration 1 Alarm received in Merlin2DotZero ...

Отзывы: