background image

11

6

Go on moving down the cursor “

” to the front of “About System”, press enter

button, it displays:

Press menu button to return.

2.3.2 Network management details refer to its User Manual.

3

System errors and Debugging

3.1 Status of indicator lights

There are 8 LED indicators on the front panel, as below:

1

 “Power” for power (Green), when turn on power switch, indicator lighting,

means the device working normal.

2

“Alarm” for alarm (Red),

indicator turn on when output stream overflow

3

If “Lock” indictor not on light, it means the device work abnormal, once it lighting

green, the device working normal.

3.2 Trouble Shooting

1). “Power” indicator not on light

Please check the power cord if inserted into the power socket correctly, or the power

switch is in the status of ON or OFF.

2

“Alarm” lighting

Please check the stream of the 6 programs, and total value of the stream,

increas the output stream value.

3

“Lock” not on light

The device working abnormal, it is fault alarming. Please check the connection wire of

LNB IN and the parameter value according to the channel number is right or wrong, so

that to do trouble shooting.

DemoduLator 6
Ver2.8

Содержание INDEM-6002-6

Страница 1: ...JXDH 6002 6 QPSK Demodulator User Manual V3 0 Chengdu Jiexun Electronics Co Ltd INDEM 6002 6 INITEL TELECOMMUNICATIONS ...

Страница 2: ...put 1 route ASI TS stream input by inner multiplexer it output one ASI TS and one backup of ASI TS stream output Support EPG or other ASI TS inputs multiplex by inner multiplexer LNB input frequency range 950 2150 MHz Interface comply with ASI standard DVB MPEG 2 both compatible SCPC MCPC compatible can receive all domestic and foreign non encrypted digital programs Polarization mode Horizontal ve...

Страница 3: ...British system F head TS input port ASI socket BNC75 1 route Package format 188 204 bite Optional Input speed ASI 80Mbps Output ASI one group two same outputs Multiplexed and selected output port PID amount 128 Output speed ASI 150Mbps Management port Ethernet port RJ45 10 100M self adaptive Size 44mm 482mm 330mm Circumstances 0 45 work 20 80 store Normal attribute Electrical source 220VAC 10 50Hz...

Страница 4: ...fterwards standard synchronous parallel data output 1 4 2 2 Data processor FGPA After FPGA got corresponding parallel data it output standard MPEG 2 stream ASI interface digital signal for the use of devices such as scrambler modulator and so on LNB input 1 Tuner Module Demodulate Module Data Processing Module LNB input 2 Tuner Module Demodulate Module LNB input 5 Tuner Module Demodulate Module Ou...

Страница 5: ...B input 4 LNB loop output 4 6 LNB input 4 LNB loop output 5 7 ASI bit stream input 8 MUX multiplexed bit stream ouput 1 2 9 Power switch ON for turn on OFF for turn off 10 Fuse pipe 2A AC250V 11 Power socket connect to AC180 AC240V 20 60MHz 12 Ground pole for complete appliance Digital Video Broadcasting Cheng Du Jiexun Electronics Co LTD 1 5 Enter Menu 7 6 3 JXDH 6002 6 QPSK Demodulator Lock6 Loc...

Страница 6: ... pc In case of any discrepancies please contact the dealer at once 1 1 2 2 I In ns st ta al ll la at ti io on n Following below steps once you are ready to install the device The every details of installing will be described in rest of this chapter please refer to the panel instructions for the specific location This chapter includes the following Check any possible losing or damage occur during t...

Страница 7: ...and extinguisher Power Requiring device power air conditioning power and lighting power are independent to each other Device power requires AC power 220V 50Hz Please carefully check before running 1 2 3 System grounding requirement All function modules good grounding designs are the base of reliability and stability of device Also they are the most important guarantee of lightning arresting and in...

Страница 8: ...tlet Connecting Power Cord User can insert one end into power supply outlet while insert the other end to AC power Connecting Grounding Wire When the device solely connects to protective ground it should adopt independent way say share the same ground with other devices When the device adopts united way the grounding resistance should be smaller than 1 Caution Before connecting power cord and LNB ...

Страница 9: ...eters state inquiry even cancel modify etc Note make sure press confirm button once you setup new parameters when it displays Saving Done means the parameters setup successful while the parameter displays symbol it means this parameter in effective otherwise means keep the original parameters or to re select parameters 2 2 Mode select Startup displays Then display main screen In the main screen pr...

Страница 10: ...ork 2 3 1 Operation instruction 1 In main screen press menu button it displays Move cursor down to the front of Set IP Address press enter button enter into screen as below Setup IP address Setup submask Setup IP address 101 101 101 010 Receiver1 UnLock F 04040MHz SR 27500k Setup IP address Setup submask Setup physical address Restore to factoty setting Setup IP address 101 101 101 010 Setup subma...

Страница 11: ...p Down button modify the parameter to the value you want to set then press enter button to confirm it displays Saving Done means modified successful Press menu button to return 4 Go on moving down the cursor to the front of Select Language press enter button It displays Move Left Right button the language marked with symbol star will be the selected language press enter button to confirm press men...

Страница 12: ... overflow 3 If Lock indictor not on light it means the device work abnormal once it lighting green the device working normal 3 2 Trouble Shooting 1 Power indicator not on light Please check the power cord if inserted into the power socket correctly or the power switch is in the status of ON or OFF 2 Alarm lighting Please check the stream of the 6 programs and total value of the stream increas the ...

Отзывы: