InisBofin Insert Roomheater
Technical Specifications
Please ensure that the
installation of the stove
complies with all the
requirements of the relevant
Health and safety at work acts
applicable.
Some materials used in fire
cement are caustic and contact
with the skin should be
avoided. In case of
contact with the skin wash
with plenty of cold water.
If any structural work is
required for installation,
please take note of the
possible presence of asbestos.
If the presence of asbestos is
found to be the case, please
contact a registered
asbestos removal firm.
Health and Safety
precautions
Proper air supply must be insured
to the room into which the stove
is to be installed. A permanent
vent opening with a minimum free
area of 75 cm sq. must be present
and care should be taken to ensure
this vent cannot be blocked. Under
no circumstances should there be
an extracting fan in the same room
as the stove, to avoid the
possibility of combustion gases
being drawn into the room.
“
This stove is not suitable for
a shared flue arrangement.
”
Name
Units
Inis Bofin
Fuel used *
wood logs
Max. measurements of wood logs
mm
Ø90 x 330
Efficiency at nominal heat output
%
69
Nominal heat output
kW
5
CO concentration (at 13% O₂)
%
0.2
Flue spigot
outside diameter
mm
163
Flue spigot
inside diameter
mm
152
Minimal chimney draught at nominal
heat output
Pa
10
Average flue gas temperature at nominal
heat output
⁰C
350
Combustion gas flow
g/s
6
Burning time of the fuel load at nominal
heat output
h
(0.7÷1)
Fuel consumption
kg/h
1.7
Combustion chamber volume
dm3
20.6
Measurements
Height
mm
588
width
mm
495
depth
mm
445
Weight , no more than
kg
98
Built dimensions (height x width x depth ) mm
549x397x359
* the time it takes for one load of fuel to burn completely
depends on the type of fuel , humidity , amount of fuel in one
load, and other factors.
Installation Instructions