Gateway BUS KNX

2-2

Using the software

application

IMPORTING THE 
SMARTLEAGUE 
PROJECT

To create a new project on first startup, select “

Import SmartLiving

solution

” from the “

Tools

” menu.

Then, in the “

Import Inim Data

” window, click-on the “

Browse file…

button and select the file in xml format, previously exported from the
SmartLeague software.

In this way, you can preview of the partitions, zones and outputs
configured through the SmartLeague software application and decide
which ones to import to the KNX gateway configuration.

IMPORTING GROUP 
ADDRESSES

In order to import the group addresses present in an ETS project, you
must first export them from the ETS software via the “

Save as CSV/

XML

” function and “

Export to OPC Server

” option.

This procedure will create a file with .ESF extension which can be
imported via “

Tools \ Import ETS solution

”.

CONFIGURING THE 
GENERAL SETTINGS

Once the importation process is complete, the “

Project Explorer

” window

will show all the control panels, partitions, zones and outputs. Select
“Control panel” to open the “

General Settings

” section:

This section will allow you to configure all the data essential for the
device functions. The “

Konnex Physical address

” option must be

consistent with the addresses assigned to the devices present in the
KNX installation.

The “

PIN code

” option must be consistent with a valid PIN code for the

SmartLiving control panel.

STATUS AND 
COMMAND ADDRESSES

The “

Project Explorer

” window will allow you to select each of the

elements in the project (control panel, partitions, zones and outputs)
and assign the status and command addresses (refer to 

paragraph 2-3

Status and command addresses

).

PROGRAMMING THE 
GATEWAY

Once all the parameters relating to the control panel, partitions, zones
and outputs are complete, you must send the configuration, via the
Ethernet network, to the IGKNX100 gateway.

In order to do so, you must select the “

Tools / Program device

” option;

a dialog window will be shown:

if it will appear “

Compilation completed successfully

”, follow the

instructions before clicking on the “

Download Configuration

button.

if it will appear “

Compilation errors

”, you can not program the

device; find the causes of errors and correct them.

2-3

Status and command

addresses

Once the importation of the SmartLiving installation project and
addresses Konnex BUS device is complete, and the communication
parameters are set correctly, the application will allow you to associate
the signals from the SmartLiving control panel with the imported KNX
devices.

The “

Project Explorer

” project window shows all the elements of the

project (control panel, partitions, zones and outputs) and all the
respective signals:

Содержание IGKNX100

Страница 1: ...1 Installation and programming manual IGKNX100 Konnex Gateway BUS Installation and programming manual EN 50131 6...

Страница 2: ...on INIM Electronics brand devices only MANUAL CODE DCMIINE0IGKNX100 VERSION 1 00 INSIDE THE BOX IGKNX module complete with extractable terminal board Installation and programming manual RS232 serial c...

Страница 3: ...ansmission LED K Programming LED L Programming button Table 2 Technical features Power supply voltage 12 24 Vdc Current draw 120 60 mA Din rail 4 standard modules Dimensions including terminal boards...

Страница 4: ...connecting the IGKNX100 by means of a serial cable plug the DB9 connector of the serial cable included into the serial port of the SmartLiving control panel and connect the three wires to the IGKNX10...

Страница 5: ...gnment of the group addresses set the security PIN for the gateway control panel communications MINIMUM REQUIREMENTS OF THE SYSTEM Supported operating systems Windows XP with SP2 Windows Vista Windows...

Страница 6: ...e addresses assigned to the devices present in the KNX installation The PIN code option must be consistent with a valid PIN code for the SmartLiving control panel STATUS AND COMMAND ADDRESSES The Proj...

Страница 7: ...ld of the corresponding signal To assign an address press the button present in each edit field to open a window which will allow you to select the KNX device from the imported tree structure CONTROL...

Страница 8: ...s addresses 2 4 Factory data The programming factory data are the IGKNX100 device addresses IP address 192 168 1 100 KNX address 15 15 255 RESTORING To restore the values of all the parameters modifie...

Страница 9: ...Configuration 9 Installation and programming manual...

Страница 10: ...per use or negligence Damage caused by fire flood wind or lightning Vandalism Fair wear and tear INIM Electronics s r l shall at its option replace or repair any defective products Improper use that i...

Отзывы: