background image

Maintenance and periodic checks

9

Installation and programming manual

5

MAINTENANCE AND

PERIODIC CHECKS

Keep the lens clean to guarantee proper operation of the detector.
A lens which is not perfectly clean may cause detection problem.
The cleaning must be done when necessary or when clearly dirty.

CLEANING 

PROCEDURE

Clean the lid and the lens with a cloth dampened with water.
Wipe with a dry cloth.

ATTENTION!

Do not use chlorine-based or abrasive products or alcohol to remove particularly

noticeable dirt.

6

DISPOSAL AND

SCRAPPING

DISMANTLING

1.

Unscrew the screws that fasten the front lid and remove it.

2.

Disconnect the detector; disconnect all the terminals on the terminal block.

3.

Divide the parts by type and dispose of them in accordance with applicable

laws.

ATTENTION!

Do not dispose of the components or any other product material in the

environment.

Seek the assistance of companies authorised to dispose of and recycle waste

materials.

Table 9: Sensor programming

DIP 3

OFF

ON

DIP 4

OFF

Triple AND:

MW + PIR 1 + PIR 2

Double AND:

MW + PIR 2

Each techmology must 

detect a motion to activate 

the alarm

The detection of the MW 

and the detection of the PIR  

2 activate the alarm (PIR1 

disabled)

ON

Double AND:

MW + PIR 1

AND of:

MW + (PIR1 OR PIR2)

The detection of the MW 

and the detection of the PIR  

1 activate the alarm (PIR2 

disabled)

The detection of the MW 

and the detection of one of 

the PIRs activate the alarm

Содержание Air2-OTT100W

Страница 1: ...1 Installation and programming manual Air2 OTT100W Triple technology wireless detector for outdoor use Installation and programming manual ...

Страница 2: ...s 6 2 3 Test function 7 2 4 Inhibition function 7 3 Installation 7 3 1 Placement 7 3 2 Installation procedure 8 4 Programming 8 5 Maintenance and periodic checks 9 6 Disposal and scrapping 9 Appendix Declaration of conformity 10 Copyright The information contained in this document is the sole property of INIM Electronics s r l No part may be copied without written authorization from INIM Electroni...

Страница 3: ...w consumption power supply range 3 to 9V Test function to signalling each alarm by LED blinking auto power off after 4 minutes Tamper and dislodgement system Inhibition LED and transmitting function for battery life saving always on Two PIRs and one microwave MW programmable sensors AND OR selectable function Mechanism for horizontal coverage adjustment Precision adjustment of lower beam patented ...

Страница 4: ... L and U brackets fixing L External screw for L and U brackets fixing M Base enclosure screw Table 3 Electronic part description N Terminal board for wire connection O Red LED for radio transmission P Yellow LED for MW Q Left green LED for each higher PIR detection R Right green LED for each lower PIR detection S Jumper T Microwave sensitivity adjustment trimmer U Higher infrared sensor PIR 1 V Lo...

Страница 5: ...arately U shaped brackets L shaped brackets 2 FUNCTIONING 2 1 Detection range ADJUSTMENT Use the trimmer MW table 3 T to adjust the microwave sensitivity the sensitivity is increased turning it clockwise By using the knob table 2 F it is possible to move the PIR2 lower in order to obtain different ranges from 3m to 12m Table 4 Technical specifications of Air2 system Operating frequency range 868 0...

Страница 6: ...evant working examples Table 6 Side view PIR2 position Distance A 3 m B 4 m C 7 m D 10 m E 12 m 1 2m 3m 4m 7m 10m 12m E A Table 7 Working examples A Detector B Protected area limit C The pet is detected only by two of the three sensors lower PIR and MW No alarm D The person is detected by all three sensors upper PIR lower PIR MW Alarm E The person is detected by two sensors upper PIR and MW No ala...

Страница 7: ...e LEDs deactivated the function inhibition is automatically activated in order to safe battery life This implies that if the detector has been installed in a populated area the detector will no switch the alarm relay if the detection area is free for three minutes at least This function avoid that the detector triggers the alarm relay continuously In order to verify if the detector is working prop...

Страница 8: ...nto the holes 7 Screw up the case with the screws Pay attention to not damage anti tam per switch support knock out Note Use the lower hole to fix the hermetic casing on the wall 8 Enroll the detector refer to Air2 BS200 transceiver installation manual 9 Insert the o ring gasket table 2 I into its seat located on the electronic holder table 2 D Note Pay attention to not stretch out the o ring gask...

Страница 9: ...ove it 2 Disconnect the detector disconnect all the terminals on the terminal block 3 Divide the parts by type and dispose of them in accordance with applicable laws ATTENTION Do not dispose of the components or any other product material in the environment Seek the assistance of companies authorised to dispose of and recycle waste materials Table 9 Sensor programming DIP 3 OFF ON DIP 4 OFF Triple...

Страница 10: ...INIM Electronics s r l dichiara che questo Air2 OTT100W è con forme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE Lietuviž Šiuo INIM Electronics s r l deklaruoja kad šis Air2 OTT100W atitinka esminius reikalavimus ir kitas 1999 5 EB Direktyvos nuostatas English Hereby INIM Electronics s r l declares that this Air2 OTT100W is in compliance with th...

Страница 11: ...11 Installation and programming manual Notes ...

Страница 12: ...via Dei Lavoratori 10 63076 Monteprandone AP Italy Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ISO 9001 Quality Management certified by BSI with certificate number FM530352 DCMIINIEA2OTT100W 120 20171222 ...

Отзывы: