Functioning
5
Installation and programming manual
The Air2-OTT100W detector communicates with INIM intrusion control panel via
the Air2 two-way wireless intrusion protection system.
1-4
Package contents
Inside the package you will find:
•
Air2-OTT100W detector
•
Hermetic casing base
•
Installing manual (this)
•
Plastic bag containing:
•• 6 stainless steel metric screw M3 x 20
•• 4 anchor screws and plugs for wall mounting
•• “O ring” gasket
Items not included in the package (accessory items to be purchased separately):
•• “U” shaped brackets
•• “L” shaped brackets
2
FUNCTIONING
2-1
Detection range
ADJUSTMENT
Use the trimmer “MW” (
table 3, T
) to adjust the microwave sensitivity (the
sensitivity is increased turning it clockwise).
By using the knob (
table 2, F
) it is possible to move the PIR2 (lower) in order to
obtain different ranges from 3m to 12m.
Table 4: Technical specifications of Air2 system
Operating frequency
range
868.0 - 868.6MHz
selectable channels
868.1, 868.3, 868.5MHz
RF output power
25mW e.r.p.
Communication type
Two-way
Modulation
GFSK
Device supervision
From 12 to 250 minutes
Table 5: Top view
A
Zones that can not be
covered
B
Zones that can be
covered by electronic
holder rotation
150°
60°
15°
15°
B
A
B
A
Содержание Air2-OTT100W