Network Type (Static IP by default)
•
Static IP: uses a manually configured IP address, matching subnet
mask, and other information for the Ethernet interface.
•
Dynamic Address (DHCP): configures the interface as a DHCP client
to obtain an IP address, the matching subnet mask, and other
information through DHCP.
•
Static IP mode
•
Primary IP: specifies the IP address of the Ethernet interface. By
default, the IP address of WAN/LAN is 192.168.1.1, and the IP
address of LAN is 192.168.2.1.
•
Netmask: specifies the subnet mask of the Ethernet interface.
•
MTU: specifies the maximum transmit unit, which is expressed in
bytes. The default value is 1500.
•
Speed/Duplex, including:
•
Auto Negotiation
•
1000M Full Duplex
•
1000M Half Duplex
•
100M Full Duplex
•
100M Half Duplex
•
10M Full Duplex
Содержание InGateway502
Страница 1: ......
Страница 8: ...4 2 2 Structure and Dimensions Figure 2 2 1 Wall Mounting A Figure 2 3 2 Wall Mounting B...
Страница 22: ...18 Figure 3 8 2 4 Pulse output Note This section is only applicable to IG500 with industrial interfaces...
Страница 48: ...44 The following figure shows the configuration of an extended access control policy...
Страница 49: ...45 The following figure shows the configuration of an access control list...
Страница 58: ...54 Once enabled the App automatically runs and will run every time the IG502 is started...
Страница 62: ...58 After the update is completed as shown below...
Страница 66: ...62 Pulse counting The starting value is 0 After power down the value counted by the power down is retained...
Страница 67: ...63 Digital output Pulse output According to the frequency of 5000 Hz the duty cycle is 50 for the pulse output...
Страница 71: ...67...
Страница 72: ...68 After the configuration is completed you can obtain DI0 Counter Value 4 7 System 4 7 1 System Time...