Challenge: specifies the challenge code of the certificate, which is required for
certificate revocation (optional).
•
Challenge Confirm: Enter the challenge code again to confirm the setting.
•
Unstructured address: specifies the IP address of the certificate.
•
RSA Key Length: specifies the length of the RSA key. The valid value range is
128-2048, and the unit is bit.
•
Poll Interval: specifies the interval at which the device queries the current
certificate status from the server. The valid value range is 30-3600, and the unit
is second.
•
Poll Timeout: specifies the maximum duration for querying the certificate
status. The device considers the certificate application fails when the timeout
period expires. The valid value range is 30-86400, and the unit is second.
•
Revocation: enables or disables certificate revocation.
•
CRL URL: specifies the URL of the certificate revocation list (CRL)
distribution point.
•
OCSP URL: specifies the URL of the Online Certificate Status Protocol
(OCSP) server. Generally, it is the same as the URL of the CA server.
Note: When using a certificate, ensure that the system time is consistent with the actual
time.
Содержание InGateway502
Страница 1: ......
Страница 8: ...4 2 2 Structure and Dimensions Figure 2 2 1 Wall Mounting A Figure 2 3 2 Wall Mounting B...
Страница 22: ...18 Figure 3 8 2 4 Pulse output Note This section is only applicable to IG500 with industrial interfaces...
Страница 48: ...44 The following figure shows the configuration of an extended access control policy...
Страница 49: ...45 The following figure shows the configuration of an access control list...
Страница 58: ...54 Once enabled the App automatically runs and will run every time the IG502 is started...
Страница 62: ...58 After the update is completed as shown below...
Страница 66: ...62 Pulse counting The starting value is 0 After power down the value counted by the power down is retained...
Страница 67: ...63 Digital output Pulse output According to the frequency of 5000 Hz the duty cycle is 50 for the pulse output...
Страница 71: ...67...
Страница 72: ...68 After the configuration is completed you can obtain DI0 Counter Value 4 7 System 4 7 1 System Time...