The AC connection must be made via one of the distribution diagrams indicated in section 5.6. The installation
must use single-pole cables with a copper or aluminum conductor.
The connection of two cables per phase with a section of up to 240 mm
2
is permitted, and a cable with the same
section for the neutral and the protection (ground).
CAUTION
If using aluminum cables, the installer must provide the necessary means to prevent galvanic coupling (bipolar
terminals, bimetallic interfaces, etc.).
The dimensioning of the ground wiring will be the responsibility of the installer and must meet applicable
regulatory requirements in the installation.
The connection admits a cable section of between 95 mm
2
and 240 mm
2
. The range of admissible diameters for
the input cables is between 18 and 29 mm. The cables must finish in an M8 spade terminal.
8.3. Connection process
1. Insert the wiring through the cable inlets provided in the lower part of the charger.
Fig. 6 Power cable steps
77
AC connection
Ingeteam
Содержание INGEREV RAPID 120
Страница 3: ...ACA2011IQM01_ Deutsch DE English EN Espa ol ES Fran ais FR Italiano IT Portugu s PT 3 Ingeteam...
Страница 44: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 84: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 124: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 164: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 204: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 244: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 245: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 246: ...Anmerkungen Notes Notas Remarques Note Notas...
Страница 248: ...ACA2011IQM01_ 08 2021 Ingeteam Power Technology S A www ingeteam com...