11
Folder system
Ingeteam
Power reference table as per phases, voltage and current
Three phase
400V 6 A
4.15 kW
400V 8 A
5.54 kW
400V 10 A
6.92 kW
400V 12 A
8.31 kW
400V 16 A
11.08 kW
400V 20 A
13.85 kW
400V 24 A
16.62 kW
400V 28 A
19.39 kW
400V 32 A
22.17 kW
start_deferred_charge
Enables the start time of the deferred charge to be programmed. This variable is disabled by default.
To program the start of the deferred charge, a
user.ini
file must be uploaded with a variable that has a valid time
programmed.
The format of the variable is 24 hours, set as follows
hh:mm:ss
.
Example:
start_deferred_charge = “23:05:00”;
To disable the end of the deferred charge a
user.ini
file must be uploaded containing an empty variable.
Example:
start_deferred_charge = “”;
finish_deferred_charge
Enables the end time of the deferred charge program to be programmed. This variable is disabled by default.
To program the end of the deferred charge a
user.ini
file must be uploaded with a variable that has a valid time
programmed.
The format of the variable is 24 hours, set as follows
hh:mm:ss
.
Example:
finish_deferred_charge = “09:55:00”;
To disable the end of the deferred charge a
user.ini
file must be loaded containing an empty variable.
Example:
finish_deferred_charge = “”;
4.3. Firmware
The device firmware must go in this folder if an update is necessary.
The extension of the firmware filename is
.bin
.
4.4. Sessions
This folder houses the file that contains all the information relating to the charging sessions of the device and the
important warnings, alarms and events that have taken place.
If the unit has an energy meter, the stored information will include the consumption rates of each session.
Otherwise, only information on the duration of the sessions will be available.
The file format is plain text in
csv
format so that it can easily be imported from a spreadsheet application or other
data treatment systems.
If the file does not exist, a new one is generated.
If the file already exists, the new information is added to it without deleting the existing information.
ABA2021IQM05_A - Configuration
EN
ES
FR
IT
Содержание Ingerev Garage
Страница 1: ...INGEREV GARAGE Basic Configuration Configuraci n Configuration Configurazione...
Страница 3: ...3 Ingeteam ABA2021IQM05_A English EN Espa ol ES Fran ais FR Italiano IT...
Страница 53: ...Notes Notas Remarques Note...
Страница 54: ...Notes Notas Remarques Note...
Страница 56: ...ABA2021IQM05_A 09 2016 Ingeteam Power Technology S A www ingeteam com...