Connection of accessories
Ingeteam
ABS2011IQM01_G - Installation and Operation Manual
5. Guide the TCP Ethernet wiring and insert the RJ45 connector in place, ensuring the wiring is not tight
and has a certain amount of slack. Use a cable tie to secure it.
6. Tighten the packing gland to ensure it is sealed.
7.3. RS-485 communication connection
This unit does not have standard RS-485 communication. If you wish to have this type of communication, you can
purchase the AAX7051 communications kit.
This communication type has all functionalities except firmware loading. The firmware must be loaded via
Ethernet, Wifi or USB.
7.3.1. Cabling requirements
Use a cable with a diameter of 4.5 to 10 mm. The passage to the inside of the unit must be done through a M16
packing gland.