x8I or x12I and Pressure Transducer Wire: The x8I or
x12I and the pressure transducer interconnection is
designed to use 2-conductor shielded cable. (18gauge).
All external wiring to the x8I or x12I should be made
through the holes (grommets are provided) in the
x8I or x12I enclosure (8 in total). Drilling or tapping
additional holes in the enclosure can result metal
shavings making contact with the circuit boards.
Damage due to metal shavings in the circuit boards is
not covered by warranty.
Power / Local Disconnect (Breaker): Incoming power
(115vAC/230vAC, single phase) should be fused (100vA)
and a local disconnect provided. The power source
should be regulated and noise free. The use of a power
supply regulator might be required in applications
where unregulated power is an issue.
•
•
•
Confirm that all electrical connections are made
properly and tightened and conform to local standards.
Common Receiver: The x8I or x12I must have its
pressure transducer located in a common receiver for
proper Wet Side or Dry Side System pressure control.
Pressure Transducer Installation: The pressure
transducer threads are BPT G1/4” DIN3852, Form E,
Inox 1, 4305 stainless. It is the equivalent of ¼” NPT.
ASSISTANCE
Contacting Technical Support Services or Service
Bulletins listed on the IR ServiceNet can provide further
assistance if there are other questions or concerns prior
to Installation and Start-up.
•
•
•
INTELLISyS CONTROLLER E-PROM REfERENCE LIST
MINIMUM RECOMMENDED E-PROM LEVELS - INTELLISyS CONTROLLERS
IntelliSys - first Generation
“REDEyE”
SSR 50 - 450HP
1 & 2 stg
2.4
Sierra 100 - 200HP
2.7
Recip
1.62
IntelliSys - Second Generation
“SG”
IntelliSys - Second Edition
“SE”
SSR 50 - 450
1 & 2 stg
1.5
SSR 15 - 100HP
1.75
SSR 75 - 350kW
ESA
1.5
SSR - UP (Pegasus)
1.23
Sierra 125-400HP
1.35
SSR 22 - 150kW
ESA
1.93
recip
1.28
Sierra 50 - 100HP
1.3
IntelliSys - Nirvana
“SGN”
Nirvana CC 100 - 200HP
1.45
IntelliSys - Nirvana
“SGNe”
Nirvana CC 50 - 300HP
2.4
Nirvana OF 50 - 200HP
1.2
Содержание X12I
Страница 32: ...32 VX Box Connection VX Box Power Supply Connection...
Страница 33: ......