background image

941256_00(1) Page 4 of 4

DOGGING INDICATOR FUNCTIONAL TEST

8

Install new cover plate and cut to proper length (if required).

Cut flush to mechanism case

(minimum cover plate length is 8-7/8”)

9

Install the end cap.

End cap

Note: Hex dogging shown below. Cylinder
dogging is the same except it uses key in
cylinder rather than hex key in hole.

1. Depress pushbar and hold.
2. Place hex key in hole as shown and turn

clockwise. Push bar stays in down position.

3. Device is now dogged and indicator light

should not be flashing.

CW

4. To undog device, place hex key in hole as

shown and turn counterclockwise releasing
pushbar.

5. With device undogged, light should flash

every 5 seconds.

Hex key

CCW

Indicator light

Remove anti-rattle clip if

necessary for cutting

Anti-rattle clip

2” minimum

When battery is low, the indicator light will double flash every 5 seconds. Then the batteries
should be changed within 3 days.

BATTERY LOW INDICATION

Key removed during

installation

DOGGED - NOT FLASHING

UNDOGGED - FLASHING

Отзывы: