AC-SVX002C-EN
37
Power Supply Wiring
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e w
w//C
Ca
ap
pa
acciitto
orrss!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w tth
he
esse
e iin
nssttrru
uccttiio
on
nss cco
ou
ulld
d rre
essu
ulltt iin
n
d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss a
an
nd
d d
diisscch
ha
arrg
ge
e a
allll m
mo
otto
orr sstta
arrtt//rru
un
n a
an
nd
d
A
AF
FD
D ((A
Ad
da
ap
pttiiv
ve
e F
Frre
eq
qu
ue
en
nccy
y™
™ D
Drriiv
ve
e)) cca
ap
pa
acciitto
orrss
b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt
p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
nn
no
ott b
be
e
iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d..
••
F
Fo
orr v
va
arriia
ab
blle
e ffrre
eq
qu
ue
en
nccy
y d
drriiv
ve
ess o
orr o
otth
he
err e
en
ne
errg
gy
y
sstto
orriin
ng
g cco
om
mp
po
on
ne
en
nttss p
prro
ov
viid
de
ed
d b
by
y T
Trra
an
ne
e o
orr
o
otth
he
errss,, rre
effe
err tto
o tth
he
e a
ap
pp
prro
op
prriia
atte
e
m
ma
an
nu
uffa
accttu
urre
err’’ss lliitte
erra
attu
urre
e ffo
orr a
allllo
ow
wa
ab
blle
e
w
wa
aiittiin
ng
g p
pe
erriio
od
dss ffo
orr d
diisscch
ha
arrg
ge
e o
off cca
ap
pa
acciitto
orrss..
V
Ve
erriiffy
y w
wiitth
h a
an
n a
ap
pp
prro
op
prriia
atte
e v
vo
ollttm
me
ette
err tth
ha
att a
allll
cca
ap
pa
acciitto
orrss h
ha
av
ve
e d
diisscch
ha
arrg
ge
ed
d..
••
D
DC
C b
bu
uss cca
ap
pa
acciitto
orrss rre
etta
aiin
n h
ha
azza
arrd
do
ou
uss v
vo
olltta
ag
ge
ess
a
afftte
err iin
np
pu
utt p
po
ow
we
err h
ha
ass b
be
ee
en
n d
diisscco
on
nn
ne
ecctte
ed
d..
F
Fo
ollllo
ow
w p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o
e
en
nssu
urre
e tth
he
e p
po
ow
we
err cca
an
nn
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y
e
en
ne
errg
giizze
ed
d.. A
Afftte
err d
diisscco
on
nn
ne
eccttiin
ng
g iin
np
pu
utt p
po
ow
we
err,,
w
wa
aiitt ffiiv
ve
e ((5
5)) m
miin
nu
utte
ess ffo
orr tth
he
e D
DC
C cca
ap
pa
acciitto
orrss tto
o
d
diisscch
ha
arrg
ge
e,, tth
he
en
n cch
he
ecckk tth
he
e v
vo
olltta
ag
ge
e w
wiitth
h a
a
v
vo
ollttm
me
ette
err.. M
Ma
akke
e ssu
urre
e D
DC
C b
bu
uss cca
ap
pa
acciitto
orrss a
arre
e
d
diisscch
ha
arrg
ge
ed
d ((0
0 V
VD
DC
C)) b
be
effo
orre
e tto
ou
ucch
hiin
ng
g a
an
ny
y
iin
ntte
errn
na
all cco
om
mp
po
on
ne
en
nttss..
F
Fo
orr a
ad
dd
diittiio
on
na
all iin
nffo
orrm
ma
attiio
on
n rre
eg
ga
arrd
diin
ng
g tth
he
e ssa
affe
e
d
diisscch
ha
arrg
ge
e o
off cca
ap
pa
acciitto
orrss,, sse
ee
e A
Ad
da
ap
pttiiv
ve
e F
Frre
eq
qu
ue
en
nccy
y
™
™
D
Drriiv
ve
e C
Ca
ap
pa
acciitty
y D
Diisscch
ha
arrg
ge
e sse
eccttiio
on
n,, a
an
nd
d P
PR
RO
OD
D--
S
SV
VB
B0
06
6*
*--E
EN
N..
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
All power supply wiring must be sized and selected
accordingly by the project engineer in accordance with
NEC Table 310-16.
All wiring must comply with local codes and the
National Electrical Code. The installing (or electrical)
contractor must provide and install the system
interconnecting wiring, as well as the power supply
wiring. It must be properly sized and equipped with the
appropriate fused disconnect switches.
The type and installation location(s) of the fused
disconnects must comply with all applicable codes.
N
NO
OT
TIIC
CE
E
U
Usse
e C
Co
op
pp
pe
err C
Co
on
nd
du
ucctto
orrss O
On
nlly
y!!
F
Fa
aiillu
urre
e tto
o u
usse
e cco
op
pp
pe
err cco
on
nd
du
ucctto
orrss cco
ou
ulld
d rre
essu
ulltt iin
n
e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e a
ass tth
he
e e
eq
qu
uiip
pm
me
en
ntt w
wa
ass n
no
ott
d
de
essiig
gn
ne
ed
d o
orr q
qu
ua
alliiffiie
ed
d tto
o a
acccce
ep
ptt o
otth
he
err tty
yp
pe
ess o
off
cco
on
nd
du
ucctto
orrss..
See Dimensions and Weights chapter for location of
incoming customer power locations in the control
panel.
Cut holes into the location indicated for the
appropriately-sized power wiring conduits. The wiring
is passed through these conduits and connected to the
terminal blocks, or circuit breakers.
The high voltage field-provided connections are made
through patch plate on the right side of the main
control panel.
To provide proper phasing of 3-phase input, make
connections as shown in field wiring diagrams and as
stated on the WARNING label in the starter panel.
Proper equipment ground must be provided to each
ground connection in the panel (one for each
customer-supplied conductor per phase).
The low voltage connections are made through
knockouts provided on the left side of the control panel.
Additional grounds may be required for each 115 volt
power supply to the unit. Green lugs are provided for
115V customer wiring.
Control Power Supply
The unit is equipped with a control power transformer.
It is not necessary to provide additional control power
voltage to the unit. No other loads should be connected
to the control power transformer.
All units are factory-connected for appropriate labeled
voltages.
Heater Power Supply
The evaporator shell is insulated from ambient air and
protected from freezing for temperature down to -4°F
by two thermostatically-controlled immersion heaters
combined with evaporator pumps activation through
Tracer
®
UC800. Whenever the ambient temperature
drops below 32°F the thermostat energizes the heaters
and the Tracer UC800 activates the pumps. If ambient
temperatures below -4°F are expected, contact your
local Trane office.