68
TK 56218-2-OP-EN
capacity which results in rapid temperature changes. Sensitive dry cargo
may be damaged as a result.
•
If running a Pretrip Test on a trailer that has just been washed down, the
extremely high humidity inside the trailer may result in false test results.
•
If running a Pretrip Test on a trailer loaded with sensitive cargo, monitor
the load temperature during the test as normal temperature control is
suspended during pre-trip operation.
•
Always perform Pretrip Tests with the trailer cargo doors closed to
prevent false test failures.
Pretrip Test Sequence
Pretrip tests proceed in the order shown below. A Full Pretrip Test is started
with the engine or electric motor not running and includes all tests. A
Running Pretrip Test is started with the engine or electric motor running and
does not include the Amp Checks or Engine Start Check.
•
A
Am
mp
p C
Ch
he
ecckkss:: Each electrical control component is energized and the
current drawn is confirmed as within specification.
•
E
En
ng
giin
ne
e S
Stta
arrtt:: The engine will start automatically.
•
D
De
effrro
osstt:: If the coil temperature is below 45 F (7 C), a defrost cycle is
initiated.
•
R
RP
PM
M C
Ch
he
ecckk:: The engine RPM in high and low speed is checked during
the Cool Check.
•
C
Co
oo
oll C
Ch
he
ecckk:: The ability of the unit to cool in low speed is checked.
•
H
He
ea
att C
Ch
he
ecckk:: The ability of the unit to heat in low speed is checked.
•
R
Re
ep
po
orrtt T
Te
esstt R
Re
essu
ullttss:: The test results are reported as PASS, CHECK, or
FAIL when the Pretrip Test is completed. If test results are CHECK or FAIL
alarm codes will exist to direct the technician to the source of the
problem.
Performing a Pretrip Test
If a Pretrip Test is initiated with the engine or electric motor not running, a
Full Pretrip Test will be performed. If a Pretrip Test is initiated with the
engine or electric motor running, a Running Pretrip Test is performed.
•
Before initiating a Pretrip Test, clear all alarm codes.
•
To stop a Pretrip Test at any time, turn the unit off.
Pretrip Tests are initiated using the Pretrip Menu. From the Standard
Display, press the MENU Key (
).