Table 1.

Heater information  

Model Number

Used With

BAYHTRS309

TSC072F3

BAYHTRS318

BAYHTRS327

BAYHTRS336

BAYHTRS409

TSC072F4

BAYHTRS418

TSC072F4

TSC072ED

WSC072ED

WSC090ED

TSC090ED

BAYHTRS427

BAYHTRS436

BAYHTRSW09

TSC072FW

BAYHTRSW18

BAYHTRSW27

BAYHTRSW36

BAYHTRT309

TSC092F3

TSC102F3

BAYHTRT318

BAYHTRT327

BAYHTRT336

BAYHTRT409

TSC092F4

TSC102F4

BAYHTRT418

BAYHTRT427

TSC092F4

TSC102F4

TSC102ED

BAYHTRT436

TSC120ED

WSC120ED

BAYHTRT454

TSC120ED

WSC120ED

BAYHTRTW18

TSC092EW

TSC102EW

BAYHTRTW27

BAYHTRTW36

BAYHTRA309

THC074F3, TZC072F3

THC092F3, TZC090F3

THC102F3, TZC102F3

 

BAYHTRA318

TSC120F3

THC074F3

THC092F3

THC102F3

BAYHTRA327

TSC120F3

THC074F3, TZC072F3

THC092F3, TZC090F3

THC102F3, TZC102F3

BAYHTRZ318

TZC072F3

TZC090F3

TZC102F3

BAYHTRA336

TSC120F3

THC074F3

THC092F3

THC102F3

BAYHTRZ336

TZC072F3

 TZC090F3

TZC102F3

BAYHTRA354

TSC120F3

BAYHTRA409

THC074F4

THC092F4

BAYHTRZ409

TZC072F4

TZC090F4

TZC102F4

BAYHTRA418

TSC120F4

THC074F4, TZC072F4

THC092F4, TZC090F4

THC102F4, TZC102F4

BAYHTRA427

TSC120F4

THC074F4, TZC072F4 

THC092F4, TZC090F4

THC102F4, TZC102F4

BAYHTRA436

TSC120F4

THC074F4, TZC072F4

THC092F4, TZC090F4

THC102F4, TZC102F4

BAYHTRA454

TSC120F4

BAYHTRZ454A

TZC120F4

BAYHTRAW18

TSC120FW

 TZC072FW

 THC092FW, TZC090FW

THC102FW, TZC102FW

BAYHTRAW36

TSC120FW

TZC072FW

THC092FW, TZC090FW

THC102FW, TZC102FW

BAYHTRAW54

TSC120FW

BAYHTRB318

WSC120E3

BAYHTRB327

WSC120E3

BAYHTRB336

WSC120E3

BAYHTRB354

WSC120E3

BAYHTRB418

WSC120E4

Содержание Precedent BAYHTRA309

Страница 1: ...edge and training Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment Electric Heaters Precedent 6 to 10 Ton Models Installation Instructions Model Numbers Used With See General Information ACC...

Страница 2: ...avoided could result in death or serious injury CAUTIONs Indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury It could also be used to alert against unsafe practices NOTICE Indicates a situation that could result in equipment or property damage only accidents WARNING Proper Field Wiring and Grounding Required Failure to follow code could result ...

Страница 3: ... EN 3 to its content without obligation to notify any person of such revision or change Trademarks All trademarks referenced in this document are the trademarks of their respective owners Revision History Updated eFlex models ...

Страница 4: ...4 ACC SVN67H EN Table of Contents General Information 5 General 6 Inspection 7 Installation 8 Electrical Data 12 ...

Страница 5: ... THC074F3 THC092F3 THC102F3 BAYHTRA327 TSC120F3 THC074F3 TZC072F3 THC092F3 TZC090F3 THC102F3 TZC102F3 BAYHTRZ318 TZC072F3 TZC090F3 TZC102F3 BAYHTRA336 TSC120F3 THC074F3 THC092F3 THC102F3 BAYHTRZ336 TZC072F3 TZC090F3 TZC102F3 BAYHTRA354 TSC120F3 BAYHTRA409 THC074F4 THC092F4 BAYHTRZ409 TZC072F4 TZC090F4 TZC102F4 BAYHTRA418 TSC120F4 THC074F4 TZC072F4 THC092F4 TZC090F4 THC102F4 TZC102F4 BAYHTRA427 TSC...

Страница 6: ...354 THC120E3 BAYHTRZ354A TZC120F3 BAYHTRD418 THC120E4 TZC120F4 BAYHTRD427 THC120E4 TZC120F4 BAYHTRD436 THC120E4 BAYHTRZ436A TZC120F4 BAYHTRD454 THC120E4 BAYHTRZ454A TZC120F4 BAYHTRU309 THC072F3 WSC090E3 BAYHTRU318 THC072F3 WSC090E3 BAYHTRU327 THC072F3 WSC090E3 BAYHTRU336 THC072F3 WSC090E3 BAYHTRU409 THC072F4 WSC090E4 BAYHTRU418 THC072F4 WSC090E4 BAYHTRU427 THC072F4 WSC090E4 BAYHTRU436 THC072F4 WSC...

Страница 7: ...mage is found it must be reported immediately and a claim made against the transportation company 3 Check the heater nameplate model number and compare with the electrical data tables Ensure that the available power supply and unit s model number complies with the particular heater being used Figure 1 Electromechanical wiring diagram ...

Страница 8: ... 7 Refer to Table 2 If the unit heater combination being installed is the same as any in this table and the application is for horizontal airflow the limit control TCO A must be replaced with the extra limit control shipped with the heater Replace TCO A following the instructions in steps 8 and 9 If the unit heater combination being installed does not correspond to any in this table or if the appl...

Страница 9: ...g to engage the support rod with the support rod hanger The BAYHTRA BAYHTRB and BAYHTRD models will have a guide rod and a support bracket to help with the installation See Figure 5 Be very careful to avoid dragging the heater element on the edges of the opening in vestibule panel as this could damage or pinch the heater elements resulting in a short circuit Engage the bottom edge of heater elemen...

Страница 10: ...lush against center post and secure each door stop with 1 or 2 screws See zoom view in Figure 8 or Figure 9 14 Remove the wire nuts from W1 W2 and W3 15 For models with the control box in the outdoor section route the wires through the wire access opening in the divider panel then up to the unit control box entering through the bottom wire access opening on the left side See Figure 8 For models wi...

Страница 11: ...element with ohmmeter and verify that heater element terminals are electrically isolated from cabinet and ground infinite resistance On downflow units with or without duct work installed or horizontal units without ductwork installed remove horizontal supply cover and carefully inspect elements after installation for damage or proximity to supporting structure or cabinet At least 1 4 clearance is ...

Страница 12: ...int connection standard efficiency Standard Indoor Motor Oversized Indoor Motor Tons Unit Model Number Heater Model Number Heater kW Rating a Control Stages MCA Max Fuse Size or Max Circuit Breaker MCA Max Fuse Size or Max Circuit Breaker 208 230 Volts Three Phase 6 TSC072F3 BAYHTRS309 6 8 9 0 1 36 5 36 5 50 50 37 8 37 8 60 60 6 TSC072F3 BAYHTRS318 13 5 18 0 1 53 1 60 4 60 70 54 8 62 0 60 70 6 TSC...

Страница 13: ...9 9 0 1 13 0 20 14 0 20 6 TSC072FW BAYHTRSW18 18 0 1 23 8 25 24 8 25 6 TSC072FW BAYHTRSW27 27 0 2 34 6 35 35 6 40 6 TSC072FW BAYHTRSW36 36 0 2 45 4 50 46 4 50 7 5 TSC090FW BAYHTRWW18 18 0 1 23 4 25 25 9 30 7 5 TSC090FW BAYHTRWW27 27 0 2 34 3 35 36 8 40 7 5 TSC090FW BAYHTRWW36 36 0 2 45 0 45 47 5 50 7 5 b TSC092FW 5AYHTRTW18 18 0 1 23 4 25 26 3 30 7 5 b TSC092FW BAYHTRTW27 27 0 2 34 3 35 37 1 40 7 ...

Страница 14: ... 2 145 8 160 2 150 175 10 WSC120E3 BAYHTRB354 40 6 54 0 2 192 7 181 8 200 200 460 Volts Three Phase 6 WSC072E4 BAYHTRW409 9 0 1 33 8 40 34 4 40 6 WSC072E4 BAYHTRW418 18 0 1 47 4 50 48 0 50 6 WSC072E4 BAYHTRW427 27 0 2 60 9 70 61 5 70 6 WSC072E4 BAYHTRW436 36 0 2 74 4 80 75 0 80 7 5 WSC090E4 BAYHTRU409 9 0 1 32 5 40 35 4 40 7 5 WSC090E4 BAYHTRU418 18 0 1 46 1 50 49 0 50 7 5 WSC090E4 BAYHTRU427 27 0...

Страница 15: ...HC092F3 BAYHTRA336 27 0 36 0 2 104 5 118 9 110 125 7 5 TZC090F3 BAYHTRA309A 6 8 9 1 18 8 21 7 52 52 7 5 TZC090F3 BAYHTRZ318A 13 5 18 1 37 5 43 3 86 86 7 5 TZC090F3 BAYHTRA327A 20 3 27 2 56 3 65 0 120 120 7 5 TZC090F3 BAYHTRZ336A 27 36 2 75 1 86 6 154 154 8 5 THC102F3 BAYHTRA309 6 8 9 0 1 42 0 42 0 50 50 8 5 THC102F3 BAYHTRA318 13 5 18 0 1 57 5 64 8 60 70 8 5 THC102F3 BAYHTRA327 20 3 27 0 2 81 0 91...

Страница 16: ... 3 77 10 THC120F4 BAYHTRD418 18 0 1 32 5 35 10 THC120F4 BAYHTRD427 27 0 2 46 0 50 10 THC120F4 BAYHTRD436 36 0 2 59 5 60 10 THC120F4 BAYHTRD454 54 0 2 70 4 80 10 TZC120F4 BAYHTRD418A 18 1 21 7 43 10 TZC120F4 BAYHTRD427A 27 2 32 5 60 10 TZC120F4 BAYHTRZ436A 36 2 43 3 77 10 TZC120F4 BAYHTRZ454A 54 2 65 0 91 575 Volts Three Phase 6 TZC072FW BAYHTRAW18 18 1 17 3 37 6 TZC072FW BAYHTRAW36 36 2 34 6 64 7 ...

Страница 17: ...ferent airflow use the following formula Temperature rise C across electric heater kW x 2985 M3 H c To calculate the temperature rise in Fahrenheit at different airflow use the following formula Temperature rise F across electric heater kW x 3414 1 08 H Table 8 Air temperature rise 380 415 volt 50 hz a Degrees C b Degrees F c 6 Ton 7 5 Ton 8 5 Ton 10 Ton 6 Ton 7 5 Ton 8 5 Ton 10 Ton 4100 M3 H 5100...

Страница 18: ...16 9 20 2 58 69 2 40 9 43 9 45 45 40 9 43 9 45 45 BAYHTRT436 22 6 26 9 78 92 2 51 6 55 5 60 60 51 6 55 5 60 60 BAYHTRT454 33 8 40 4 116 138 2 73 1 79 0 80 80 73 1 79 0 80 80 a kW and MBh shown for 380V 415V Table 10 Heat pump units with electric heater single power source 380 415 volt three phase 50hz Standard Indoor Fan Motor Oversized Indoor Fan Motor Unit Model No Heater Model No Heater a kW Ra...

Страница 19: ......

Страница 20: ...nd increase industrial productivity and efficiency We are a global business committed to a world of sustainable progress and enduring results For more information visit www ingersollrand com Ingersoll Rand has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice We are committed to using environmentally conscious prin...

Отзывы: