background image

Page 8 of 8 

PD05P-XXX-XXX-B (en)

PN 97999-1164

DIMENSIONAL DATA

DIMENSIONS

A  -  10-1/32” (254.8 mm)
B  -  10-3/32” (256.1 mm)
C  -  6-3/16” (157.1 mm)
D  -  2” (51.0 mm)
E  -  6-3/4” (171.0 mm)

F  -  6-1/32” (153.1 mm)
G  -  10-29/32” (276.8 mm)
H  -  4-29/32” (124.2 mm)
J  -  5-17/32” (140.2 mm)
K  -  5/16” (8.0 mm)

L  -  1-15/16” (48.9 mm)
M -  3/8” (9.6 mm)
N  -  6-11/32” (160.5 mm)
P  -  8-29/32” (225.9 mm)
Q  -  5-1/32” (127.4 mm)

Figure 5

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Pump Model 

“U” Material Inlet / Outlet

PD05P-AXS-XXX-B 

1/2 - 14 N.P.T.F. - 1

PD05P-BXS-XXX-B 

Rp 1/2 (1/2 - 14 BSP, parallel)

R  -  3-3/32” (78.5 mm)
S  -  1-9/16” (39.7 mm)
T  -  1/4 - 18 P.T.F. SAE Short
U - see below

TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.
Check tightness of (6) diaphragm nut.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check “O” rings between intake manifold and fl uid caps.
Check tightness of (6) diaphragm nut.

Motor blows air out main exhaust when stalled on either 

stroke.

Check “U” cups on (111) spool in major valve.
Check (141) valve plate and (140) insert for wear.
Check (169) “U” cup on (167) pilot piston.

Low output volume.

Check air supply.
Check for plugged outlet hose.
For the pump to prime itself, it must be mounted in the vertical 
position so that the balls will check by gravity.
Check for pump cavitation - suction pipe should be sized at 
least as large as the inlet thread diameter of the pump for 
proper fl ow if high viscosity fl uids are being pumped. Suction 
hose must be a non-collapsing type, capable of pulling a high 
volume.
Check all joints on the inlet manifolds and suction connections. 
These must be air tight.
Inspect the pump for solid objects lodged in the diaphragm 
chamber or the seat area.

M

H

J

G

S

F

E

L

R

C

D

N

B

Q

P

A

K

U - Material Outlet

T - Air Inlet

U - Material Inlet

U - Material Inlet

U - Material Outlet

Содержание PD05P-XXX-XXX-B

Страница 1: ...ial Acetal 10 to 180 F 12 to 82 C Hytrel 20 to 150 F 29 to 66 C Kynar PVDF 10 to 200 F 12 to 93 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 35 to 175 F 2 to 79 C Polyurethane 10 to 150 F 12 to 66 C...

Страница 2: ...h local and national laws and safety code requirements OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE Obtain Material Safety Data Sheets...

Страница 3: ...isassembly and reassembly Keep good records of service activity and include the pump in preventive maintenance program Service kits are available to service two separate diaphragm pump functions 1 AIR...

Страница 4: ...5P XKS PD05P XLS PD05P XDS PD05P XES Item Description size Qty Part No Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl 6 Diaphragm Nut 5 16 18 2 93103 7 P 93103 7 P 93103 4 K 93103 4 K...

Страница 5: ...ply Lubriplate FML 2 grease to all O rings U cups and mating parts Apply pipe sealant to threads Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using s...

Страница 6: ...enter body Lubricate and assemble 167 pilot piston assembly into 170 bushing Assemble 173 and 174 O rings and 121 washers to 103 covers then insert 118 actuator pins through assembly Assemble 144 U cu...

Страница 7: ...large plug then insert 136 large plug into 135 valve block being sure the 111 spool is rotated to accept 140 valve insert 1 2 3 4 Assemble 107 small plug into 135 valve block Assemble 140 valve inser...

Страница 8: ...lumbing Check O rings between intake manifold and fluid caps Check tightness of 6 diaphragm nut Motor blows air out main exhaust when stalled on either stroke Check U cups on 111 spool in major valve...

Отзывы: