background image

CHEMFLO 6 (en) 

Page 5 of 16

MOTOR MOUNTING

Check rotation of the driver to be sure it coincides with the 

required rotation of the pump. When viewed from the driver 

end the rotation of the pump is CLOCKWISE.

A Pumpak shaft sleeve is machined to precisely fit the shaft 

of your driver. No provision is made for drive key and none is 

required.

Loosen the drive clamp fasteners but do not remove. 

NOTE

If the driver shaft is keyed, remove the key before attempting 

to install the Pumpak. Slide the Pumpak assembly onto the 

driver shaft, aligning the capscrew holes in the adaptor with 

the tapped holes in the driver mounting face until the adap-

tor contacts the mounting face.

Install fasteners and tighten to secure Pumpak assembly to 

the driver. First center then tighten the drive clamp assembly 

to lock the shaft sleeve onto the driver shaft.

After all fasteners are tight including the drive clamp assem-

bly, remove the Assembly shim from the suction connection. 

The shim was in place to establish clearance between the 

face of the impeller and pump housing. Rotate the driver 

slowly by hand to make certain that there is no rubbing.

TO ADJUST IMPELLER CLEARANCE:

1.  Loosen the impeller drive sleeve

2.  Use a tool such as a screwdriver to push the impeller 

back then reinsert the Assembly Shim.

3.  Seal spring tension should push the impeller forward 

and capture the shim when the screwdriver is removed.

4.  Re-tighten the shaft clamp. Remove the shim then re-

check for rubbing.

Torque Specifications

Size

Stainless Steel (ft-lbs)

Steel GR5 (ft-lbs)

5/16-18

10-14

14-20

3/8-16

20-26

26-32

1/2-13

34-42

70-80

1/2-20

40-48

N/A

5/8-18

85-95

N/A

SHIM 

(24 GAGE)

CHEMFLO

HOUSING

IMPELLER

Figure 2

RELEASED 03/Sep/2021 12:38:55 GMT

Содержание MP PUMPS CHEMFLO 6

Страница 1: ...the operator Keep for future reference OPERATOR S MANUAL CHEMFLO 6 INCLUDING OPERATION INSTALLATION AND MAINTENANCE RELEASED 8 27 21 REV A CHEMFLO 6 3 X 2 INGERSOLL RAND COMPANY INC 34800 BENNETT DR...

Страница 2: ...nstruction 316 stainless steel Flow CC Up to 450 gpm 1703 lpm Hydraulic Up to 500 gpm 1893 lpm Pedestal Up to 450 gpm 1703 lpm Head Feet CC Up to 157 ft 49m Hydraulic Up to 190 ft 58 m Pedestal Up to...

Страница 3: ...als elastomers and all wetted parts to assure compatibility before using commission of the product y Verify the chemical compatibility of the pump wetted parts and the substance being pumped flushed o...

Страница 4: ...NOT BE OPERATED DRY Pipe or hose of the same size or larger as inlet and outlet openings should be used on the installation When using pipe avoid sharp bends and use long radius elbows wherev er poss...

Страница 5: ...en tighten the drive clamp assembly to lock the shaft sleeve onto the driver shaft After all fasteners are tight including the drive clamp assem bly remove the Assembly shim from the suction connectio...

Страница 6: ...otors called impellers The action of the impeller increases the fluid s velocity and pressure and directs it towards the pump outlet WEAR AND INSPECTION POINTS Shaft Inspect threads keyways and should...

Страница 7: ...surface of the seal seat in the adaptor Slide impeller and seal assembly into the adaptor Install drive clamp assembly on the shaft sleeve but do not tighten INSTRUCTIONS FOR SET SCREW TYPE SEAL Do no...

Страница 8: ...3 8 16 x 1 63 4 21261 304 SS Cap Screw HH 5 16 18 x 7 8 4 21242 304 SS Capscrew HH 3 8 16 x 2 25 4 21269 304 SS Stud 3 8 16x2 00 4 33161 304 SS Capscrew ZPS HH 1 4 14 x 0 63 self DrillTap 4 36711 STEE...

Страница 9: ...1 29992 CAST IRON Hydraulic Motor 1 59 DISP 1 29993 CAST IRON 12 Lockwasher 1 2 2 21254 304 SS 13 Capscrew HH 1 2 13 x 1 25 2 21246 304 SS 14 Pipe Plug 1 8 NPT 2 21255 316 SS Pipe Plug 1 4 NPT 2 2126...

Страница 10: ...233 VITON O Ring AS 568 163 1 33757 EPDM O Ring AS 568 164 1 31234 TEFLON EN CAPS SIL 7 Housing Seal 1 31093 CF8M SS Housing Seal 1 32017 CF8M SS Item Description size Qty Part No Mtl 8 Slinger 1 3788...

Страница 11: ...SS PED 5 6T 2100 N A MP51282 MP31751 MP38388 CF6PMP SS PED 5 6T 9 N A MP51282 MP31751 MP35686 CF6PMP SS PED 5 93T 21 CCS N A MP51282 MP31750 MP38502 CF6PMP SS PED 5 93T 2100 N A MP51282 MP31750 MP3987...

Страница 12: ...Page 12 of 16 CHEMFLO 6 en DIMENSIONAL DATA CF6 PUMPAK FOR 145TC Figure 7 CF6 PUMPAK FOR 184TC Figure 8 RELEASED 03 Sep 2021 12 38 55 GMT...

Страница 13: ...CHEMFLO 6 en Page 13 of 16 DIMENSIONAL DATA CF6 PUMPAK FOR 215TC Figure 9 CF6 W 1 16 DISP HYDRAULIC MOTOR Figure 10 RELEASED 03 Sep 2021 12 38 55 GMT...

Страница 14: ...Page 14 of 16 CHEMFLO 6 en DIMENSIONAL DATA CF6 W 1 16 DISP HYDRAULIC MOTOR Figure 11 CF6 PED Figure 12 RELEASED 03 Sep 2021 12 38 55 GMT...

Страница 15: ...there are no obstructions in the suc tion line Check NPSHa to ensure that there is enough liquid for pump oper ation 6 Driver is not operating at rated speed 6 Check electric motor voltage check engin...

Страница 16: ...driver with pump 7 Power frame shaft is bent 7 Repalace shaft 8 Worn suction side plate or wear rings 8 Replace defective parts as required 9 Liquid heavier than expected 9 Check specific gravity and...