Ingersoll-Rand MP PUMPS CHEMFLO 4 145TC Скачать руководство пользователя страница 5

CHEMFLO 4 (en) 

Page 5 of 16

MOTOR MOUNTING

Check rotation of the driver to be sure it coincides with the 

required rotation of the pump. When viewed from the driver 

end the rotation of the pump is CLOCKWISE.

A Pumpak shaft sleeve is machined to precisely fit the shaft 

of your driver. No provision is made for drive key and none is 

required.

Loosen the drive clamp fasteners but do not remove. 

NOTE

If the driver shaft is keyed, remove the key before attempting 

to install the Pumpak. Slide the Pumpak assembly onto the 

driver shaft, aligning the capscrew holes in the adaptor with 

the tapped holes in the driver mounting face until the adap-

tor contacts the mounting face.

Install fasteners and tighten to secure Pumpak assembly to 

the driver. First center then tighten the drive clamp assembly 

to lock the shaft sleeve onto the driver shaft.

After all fasteners are tight including the drive clamp assem-

bly, remove the Assembly shim from the suction connection. 

The shim was in place to establish clearance between the 

face of the impeller and pump housing. Rotate the driver 

slowly by hand to make certain that there is no rubbing.

TO ADJUST IMPELLER CLEARANCE:

1.  Loosen the impeller drive sleeve

2.  Use a tool such as a screwdriver to push the impeller 

back then reinsert the Assembly Shim.

3.  Seal spring tension should push the impeller forward 

and capture the shim when the screwdriver is removed.

4.  Re-tighten the shaft clamp. Remove the shim then re-

check for rubbing.

Torque Specifications

Size

Stainless Steel (ft-lbs)

Steel GR5 (ft-lbs)

5/16-18

10-14

14-20

3/8-16

20-26

26-32

1/2-13

34-42

70-80

1/2-20

40-48

N/A

5/8-18

85-95

N/A

SHIM 

(24 GAGE)

CHEMFLO

HOUSING

IMPELLER

Figure 2

RELEASED 03/Sep/2021 12:38:56 GMT

Содержание MP PUMPS CHEMFLO 4 145TC

Страница 1: ...s of the operator Keep for future reference OPERATOR S MANUAL CHEMFLO 4 INCLUDING OPERATION INSTALLATION AND MAINTENANCE RELEASED 8 27 21 REV A CHEMFLO 4 2 X 1 1 2 INGERSOLL RAND COMPANY INC 34800 BEN...

Страница 2: ...num bronze Flow CC Up to 180 gpm 681 lpm Hydraulic Up to 220 gpm 833 lpm Pedestal Up to 180 gpm 681 lpm Head Feet CC Up to 80 ft 24 m Hydraulic Up to 205 ft 62 m Pedestal Up to 80 ft 24 m Impeller CC...

Страница 3: ...eals elastomers and all wetted parts to assure compatibility before using commission of the product y Verify the chemical compatibility of the pump wetted parts and the substance being pumped flushed...

Страница 4: ...NOT BE OPERATED DRY Pipe or hose of the same size or larger as inlet and outlet openings should be used on the installation When using pipe avoid sharp bends and use long radius elbows wherev er poss...

Страница 5: ...en tighten the drive clamp assembly to lock the shaft sleeve onto the driver shaft After all fasteners are tight including the drive clamp assem bly remove the Assembly shim from the suction connectio...

Страница 6: ...otors called impellers The action of the impeller increases the fluid s velocity and pressure and directs it towards the pump outlet WEAR AND INSPECTION POINTS Shaft Inspect threads keyways and should...

Страница 7: ...Install drive clamp assembly on the shaft sleeve but do not tighten Make sure the shim is installed between the impeller and the wear plate Do not remove the shim material before the drive sleeve cla...

Страница 8: ...C 1 31844 CF8M SS Impeller 3 57 56C 1 30241 CF8M SS Impeller 3 93 56C 1 30240 CF8M SS Impeller 3 25 56C 1 33751 CF8M SS Impeller 4 50 145TC 1 34209 CF8M SS Impeller 3 93 145TC 1 34407 CF8M SS Impeller...

Страница 9: ...e 145TC 1 35753 316 SS 7 See SealTable for Options Page No 11 8 Capscrew 3 8 16 X 3 4 4 25663 304 SS 9 Lockwasher 5 16 X 18 4 21238 304 SS 10 Adapter 145TC 1 33794 316 SS Item Description size Qty Par...

Страница 10: ...35598 316 SS 5 Impeller 4 50 1 29914 CF8M SS Impeller 4 25 1 31844 CF8M SS Impeller 3 57 1 39614 CF8M SS Impeller 3 76 1 30241 CF8M SS 6 Drive Sleeve 56C 1 29785 316 SS 7 See SealTable for Options Pag...

Страница 11: ...HYD 37 DISP CIWBA 4 5 MP51272 N A MP34209 MP36494 CF4PMP SS HSHYD 22DISP CI F CTL 4 5VD MP51272 N A MP34209 MP36495 CF4PMP SS HSHYD 37DISP CI F CTL 4 5VD MP51272 N A MP34209 MP30487 CF4PMP SS PED 3 57...

Страница 12: ...Page 12 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PUMPAK FOR 56C FOOTLESS MOTOR Figure 7 CF4 PUMPAK FOR 145TC MOTOR WITH FOOT Figure 8 RELEASED 03 Sep 2021 12 38 56 GMT...

Страница 13: ...CHEMFLO 4 en Page 13 of 16 DIMENSIONAL DATA CF4 0 22 DISP MOTOR Figure 9 CF4 0 37 DISP MOTOR Figure 10 RELEASED 03 Sep 2021 12 38 56 GMT...

Страница 14: ...Page 14 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PED Figure 11 RELEASED 03 Sep 2021 12 38 56 GMT...

Страница 15: ...there are no obstructions in the suc tion line Check NPSHa to ensure that there is enough liquid for pump oper ation 6 Driver is not operating at rated speed 6 Check electric motor voltage check engin...

Страница 16: ...driver with pump 7 Power frame shaft is bent 7 Repalace shaft 8 Worn suction side plate or wear rings 8 Replace defective parts as required 9 Liquid heavier than expected 9 Check specific gravity and...

Отзывы: