OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

 Be sure hoses and other components can 

withstand fluid pressures developed by this pump. 

Check any hoses for damage or wear. Be certain dis-

pensing device is clean and in proper working condi-

tion.

WARNING

 IMPROPER GROUNDING. Can increase 

spark and electrical shock risk, resulting in severe in-

jury or death. Ground pump and pumping system. 

 

y

The pumping system must be grounded when it is 

pumping, flushing, recirculating, or spraying flamma-

ble materials such as paints, solvents, lacquers, etc. 

or used in a location where surrounding atmosphere 

is conducive to spontaneous combustion. Ground the 

dispensing valve or device, containers, hoses, and any 

object to which material is being pumped.

 

y

Secure pump, connections, and all contact points to 

avoid vibration and generation of contact or static 

spark. Consult local building codes and electrical 

codes for specific grounding requirements. After 

grounding, periodically verify continuity of electrical 

path to ground. Test with an ohmmeter from each 

component (e.g., hoses, piping, pump, clamps, motor, 

base plate, etc..) to ground to ensure continuity. Ohm-

meter should show 0.1 ohms or less.

WARNING

 HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service or 

clean pump while the system is pressurized.  

WARNING

 HAZARDOUS MATERIALS. Can cause 

serious injury or property damage. Do not attempt 

to return a pump to the factory or service center that 

contains hazardous material. Safe handling practices 

must comply with local and national laws and safe-

ty code requirements.  Obtain Material Safety Data 

Sheets on all materials from the supplier for proper 

handling instructions.

CAUTION

 Check pump seals, elastomers, and all 

wetted parts to assure compatibility before using 

commission of the product.

 

y

Verify the chemical compatibility of the pump wetted 

parts and the substance being pumped, flushed or 

recirculated. Chemical compatibility may change with 

temperature and concentration of the chemical(s) 

within the substances being pumped, flushed or cir-

culated. For specific fluid compatibility, consult the 

chemical manufacturer.

CAUTION

 Maximum temperatures are based on 

mechanical stress of seals and elastomers only. Cer-

tain chemicals will significantly reduce maximum safe 

operating temperature. Consult the chemical manu-

facturer for chemical compatibility and temperature 

limits.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-

stand it’s limitations, and wear safety goggles / equip-

ment when required.

CAUTION

 Do not use the pump for the structural 

support of the piping system. Be certain the system 

components are properly supported to prevent stress 

on the pump parts.

CAUTION

 Prevent unnecessary damage to the 

pump. Do not allow pump to operate in a dry run 

condition or under cavitating conditions for extended 

periods.

CAUTION

 Use only genuine MP Pumps

®

 replace-

ment parts to assure compatible pressure rating and 

longest service life.

CAUTION

  The mechanical seal in the pump must 

not be operated dry.

CAUTION

 If a pump will be idle in freezing weather 

it should be drained or filled with the proper an-

ti-freeze.

NOTICE

 Pump should be installed in the position 

consistent with the manufactures specifications. 

NOTICE

 Re-torque all fasteners before operation. 

Creep of housing and gasket materials may cause 

fasteners to loosen. Re-torque all fasteners to insure 

against fluid leakage.

WARNING

= Hazards or unsafe practices which could 

result in severe personal injury, death or 

substantial property damage.

CAUTION

= Hazards or unsafe practices which could 

result in minor personal injury, product 

or property damage.

NOTICE

= Important installation, operation or 

maintenance information.

RELEASED 03/Sep/2021 12:38:56 GMT

Содержание MP PUMPS CHEMFLO 4 145TC

Страница 1: ...s of the operator Keep for future reference OPERATOR S MANUAL CHEMFLO 4 INCLUDING OPERATION INSTALLATION AND MAINTENANCE RELEASED 8 27 21 REV A CHEMFLO 4 2 X 1 1 2 INGERSOLL RAND COMPANY INC 34800 BEN...

Страница 2: ...num bronze Flow CC Up to 180 gpm 681 lpm Hydraulic Up to 220 gpm 833 lpm Pedestal Up to 180 gpm 681 lpm Head Feet CC Up to 80 ft 24 m Hydraulic Up to 205 ft 62 m Pedestal Up to 80 ft 24 m Impeller CC...

Страница 3: ...eals elastomers and all wetted parts to assure compatibility before using commission of the product y Verify the chemical compatibility of the pump wetted parts and the substance being pumped flushed...

Страница 4: ...NOT BE OPERATED DRY Pipe or hose of the same size or larger as inlet and outlet openings should be used on the installation When using pipe avoid sharp bends and use long radius elbows wherev er poss...

Страница 5: ...en tighten the drive clamp assembly to lock the shaft sleeve onto the driver shaft After all fasteners are tight including the drive clamp assem bly remove the Assembly shim from the suction connectio...

Страница 6: ...otors called impellers The action of the impeller increases the fluid s velocity and pressure and directs it towards the pump outlet WEAR AND INSPECTION POINTS Shaft Inspect threads keyways and should...

Страница 7: ...Install drive clamp assembly on the shaft sleeve but do not tighten Make sure the shim is installed between the impeller and the wear plate Do not remove the shim material before the drive sleeve cla...

Страница 8: ...C 1 31844 CF8M SS Impeller 3 57 56C 1 30241 CF8M SS Impeller 3 93 56C 1 30240 CF8M SS Impeller 3 25 56C 1 33751 CF8M SS Impeller 4 50 145TC 1 34209 CF8M SS Impeller 3 93 145TC 1 34407 CF8M SS Impeller...

Страница 9: ...e 145TC 1 35753 316 SS 7 See SealTable for Options Page No 11 8 Capscrew 3 8 16 X 3 4 4 25663 304 SS 9 Lockwasher 5 16 X 18 4 21238 304 SS 10 Adapter 145TC 1 33794 316 SS Item Description size Qty Par...

Страница 10: ...35598 316 SS 5 Impeller 4 50 1 29914 CF8M SS Impeller 4 25 1 31844 CF8M SS Impeller 3 57 1 39614 CF8M SS Impeller 3 76 1 30241 CF8M SS 6 Drive Sleeve 56C 1 29785 316 SS 7 See SealTable for Options Pag...

Страница 11: ...HYD 37 DISP CIWBA 4 5 MP51272 N A MP34209 MP36494 CF4PMP SS HSHYD 22DISP CI F CTL 4 5VD MP51272 N A MP34209 MP36495 CF4PMP SS HSHYD 37DISP CI F CTL 4 5VD MP51272 N A MP34209 MP30487 CF4PMP SS PED 3 57...

Страница 12: ...Page 12 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PUMPAK FOR 56C FOOTLESS MOTOR Figure 7 CF4 PUMPAK FOR 145TC MOTOR WITH FOOT Figure 8 RELEASED 03 Sep 2021 12 38 56 GMT...

Страница 13: ...CHEMFLO 4 en Page 13 of 16 DIMENSIONAL DATA CF4 0 22 DISP MOTOR Figure 9 CF4 0 37 DISP MOTOR Figure 10 RELEASED 03 Sep 2021 12 38 56 GMT...

Страница 14: ...Page 14 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PED Figure 11 RELEASED 03 Sep 2021 12 38 56 GMT...

Страница 15: ...there are no obstructions in the suc tion line Check NPSHa to ensure that there is enough liquid for pump oper ation 6 Driver is not operating at rated speed 6 Check electric motor voltage check engin...

Страница 16: ...driver with pump 7 Power frame shaft is bent 7 Repalace shaft 8 Worn suction side plate or wear rings 8 Replace defective parts as required 9 Liquid heavier than expected 9 Check specific gravity and...