9.0 OPERATING INSTRUCTIONS
9.2 INTELLISYS CONTROLS
1. Emergency stop
Pressing this switch stops the compressor immediately.
The blowdown valve will open to vent pressure in
the separator tank to atmosphere. Note: the system
downstream of the separator tank may still contain
pressure. The compressors can not be restarted until the
switch is manually reset. Turn the switch knob clockwise
and press the reset button twice to reset.
On reset the controller will display a message, indicating
that the compressor is ready to start.
2. Start
Pressing this button will activate the start sequence.
3. Stop
Pressing this button will activate the stop sequence.
4. F1
Not used.
5. F2
Not used.
6. Arrows
These up and down buttons have multiple functions
relating to the right half of the display screen. When lists
are presented, the buttons are used to move up or down
through the items on the list. The small arrow(s) displayed
in the upper right hand corner of the display screen
indicate when you can move up (designated by arrow
head pointing up) and/or down (designated by arrow
head pointing down) through the list.
When the value of a specific machine operating
parameter is highlighted on the display screen for the
purpose of changing that value, the buttons are used to
change the value itself.
7. Display buttons
The functions of the three buttons below the display
screen change and are defined by the words immediately
above them in the bottom line of the screen. Each
function, such as MAIN MENU, STATUS, etc., is described in
appropriate sections in this manual.
111213.14.59