background image

Page 2 of 12 

PP10A-XXX-XXX-A (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as 

stated on the pump model plate.

 

y

Be sure material hoses and other components are able 

to withstand fluid pressures developed by this pump. 

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion result-

ing in severe injury or death. Ground pump and 

pumping system.

 

y

Use the pump grounding screw terminal provided. 

Use ARO® part no. 94829 ground kit or connect a suit-

able ground wire (12 ga. minimum) to a good earth 

ground source.

 

y

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static 

spark.

 

y

Consult local building codes and electrical codes for 

specific grounding requirements.

 

y

After grounding, periodically verify continuity of 

electrical path to ground. Test with an ohmmeter from 

each component (e.g., hoses, pump, clamps, contain-

er, spray gun, etc.) to ground, to ensure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep inflammables away from heat, open flames and 

sparks.

 

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

 

y

Use a grounded 1” minimum ID hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in seri-

ous injury or property damage. Do not service or 

clean pump, hoses or dispensing valve while the sys-

tem is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains 

hazardous material. Safe handling practices must 

comply with local and national laws and safety code 

requirements.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum wetted parts cannot be used with 1,1,1-trichlo-

roethane, methylene chloride or other halogenated 

hydrocarbon solvents which may react and explode.

 

y

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use mod-

els containing aluminum wetted parts with food prod-

ucts for human consumption. Plated parts can contain 

trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on 

mechanical stress only. Certain chemicals will signifi-

cantly reduce maximum safe operating temperature. 

Consult the chemical manufacturer for chemical com-

patibility and temperature limits. Refer to PUMP DATA 

on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-

stand it’s limitations, and wear safety goggles / equip-

ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-

ponents are properly supported to prevent stress on 

the pump parts.

 

y

Suction and discharge connections should be flex-

ible connections (such as hose), not rigid piped, 

and should be compatible with the substance being 

pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 

for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 

life.

NOTICE

 Replacement warning labels are available 

upon request: “Static Spark & Diaphragm Rupture”  

pn \ 94080.

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

Содержание ARO PP10A Series

Страница 1: ...ping powders up to 50 lb ft3 Weight PP10X XAX XXX AXXX 28 65 lbs 12 97 kgs PP10X XSX XXX AXXX 46 2 lbs 20 9 kgs Maximum Air Inlet Pressure 50 psig 3 4 bar Maximum Fluidizing Pressure 100 psig 6 9 bar Maximum Particle Size 1 8 dia 3 3 mm MaximumTemperature Limits diaphragm ball seat materials Santoprene 40 to 225 F 40 to 107 C Dimensional Data see page 11 Mounting Dimension 4 x6 25 101 6mmx158 8mm ...

Страница 2: ...ety code requirements OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE y y Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing alu minum wetted parts cannot be used with 1 1 1 trichlo roethane methylene chloride or other halogenated hydrocarbon...

Страница 3: ...el and option chart ARO pumps feature stall resistant design modular air motor fluid sections Air operated double diaphragm pumps utilize a pressure dif ferential in the air chambers to alternately create suction and positive fluid pressure in the fluid chambers valve checks ensure a positive flow of fluid This diaphragm pump was developed to address the unique problems associated with pumping dry...

Страница 4: ...ated which should be available for fast repair and reduction of down time y y Service kits are divided to service two separate dia phragm pump functions 1 AIR SECTION 2 FLUID SEC TION The FLUID SECTION is divided further to match typical part MATERIAL OPTIONS y y Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and foreign matter during service d...

Страница 5: ...PP10A XXX XXX A en Page 5 of 12 TYPICAL CROSS SECTION Figure 3 ...

Страница 6: ...ice Kits with Seats Service Kit without Seats 7 19 33 XXX XXX Seat XXX Ball XXX Diaphragm XX Ball XX Diaphragm Diaphragm Qty Mtl O Ring Qty Mtl O Ring Qty Mtl XXA 637401 XXA 637401 XA 96267 A 2 Sp 93280 4 E 93279 4 E XXM 637401 XXM 637401 XM 96267 M 2 MSp 93282 4 T 93281 4 T MANIFOLD CONNECTION FLUID CAP MATERIAL OPTIONS PP10A XXX XXX A Aluminum Stainless Steel NPT BSP NPT BSP PP10A AAX XXX PP10A ...

Страница 7: ...0 3 27 1 Nm 131 screws 12 17 ft lbs 16 2 23 04 Nm LUBRICATION SEALANTS Apply PTFE tape to threads Apply Loctite 242 to threads at assembly Apply Loctite 271 to threads at assembly Apply Lubriplate FML 2 grease 94276 to all O rings U cups and mating parts Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners PARTS LIST PP10A ...

Страница 8: ...asing 111 spool MAJOR VALVE REASSEMBLY 1 Install new 138 and 139 U cups on 111 spool LIPS MUST FACE EACH OTHER 2 Insert 111 spool into 135 valve housing 3 Install 137 O rings on 136 plug and assemble plug to 135 valve housing securing with 105 screws 4 Install 140 valve insert 141 gasket into 135 valve housing NOTE Assemble 140 valve insert with dished side toward 141 valve plate Assemble 141 valv...

Страница 9: ... ARE METRIC 105 screw 40 50 in lbs 4 5 5 6 Nm 134 screw 40 50 in lbs 4 5 5 6 Nm LUBRICATION SEALANTS Apply Lubriplate FML 2 grease to all O rings U cups and mating parts Apply Loctite 271 to threads at assembly Apply Lubricate grease toValve Spool assemblies and Bores A replacement major valve service assembly is available separately which includes the following 637395 8 for models PP10A XXX XXX A...

Страница 10: ...D tube x 1 8 27 NPT 5 59474 56 257 Adapter 1 8 27 PTF 1 94812 258 Button BleedValve 1 8 27 NPTF 1 24130 259 Elbow 5 32 OD tube x 1 8 27 NPT 4 59756 4 260 CheckValve 2 CP10 B 261 Mounting Bracket 1 97704 262 Pipe Plug 1 4 18 NPT x 7 16 2 Y17 51 N 263 ControlValve 1 H254PS 264 Pipe Plug with 0 078 orifice 1 2 14 NPT 1 94977 265 Nipple 1 2 14 NPTF 1 x 1 1 8 1 Y27 4 C 267 Tube 1 4 OD x 20 1 59675 268 ...

Страница 11: ...meters mm C A D F Exhaust Port 3 4 14 NPT Air Inlet 1 2 14 NPTF Outlet Inlet 1 11 1 2 NPTF 1 PP10A ASS AAA A A 1 11 BSP PP10A AAS AAA A A B E DIMENSIONS A 375 21 mm B see below C 101 6 mm D 31 75 mm E 457 53 mm F 293 67 mm Pump Model B PP10A ASS AAA A 410 84 mm PP10A AAS AAA A 410 25 mm Figure 7 DIMENSIONAL DATA ...

Страница 12: ...Page 12 of 12 PP10A XXX XXX A en PN 97999 1822 ...