background image

Page 3 of 8

PH10A-XXX-XXX (en)

GENERAL DESCRIPTION

The 1” metallic diaphragm pump offers high volume delivery even at low
air pressures, easy self priming, the ability to pump various viscosity ma-
terials and the ability to pass solids (as stated in the chart above). The
pump is offered with optional wetted parts configurations to satisfy a va-
riety of application requirements. Refer to the “Model Description Chart”.

AIR AND LUBE REQUIREMENTS

WARNING

EXCESSIVE AIR PRESSURE. Can cause person-

al injury, pump damage or property damage. Do not exceed
maximum inlet air pressure as stated on pump.

S

A filter capable of filtering out particles larger than 50 microns should
be used on the air supply. There is no lubrication required other than
the “O” ring lubricant which is applied during assembly or repair.

S

If lubricated air is present, make sure that it is compatible with the “O”
rings and seals in the air motor section of the pump.

TRANSPORT AND STORAGE

S

Store in a dry place, do not remove product from box during storage.

S

Do not remove protection caps from inlet and outlet prior to installa-
tion.

S

Do not drop or damage box, handle with care.

INSTALLATION

S

Secure the diaphragm pump legs to a suitable surface to ensure
against damage by excessive vibration.

S

Pump cycle rate and operating pressure should be controlled by us-
ing an air regulator on the air supply.

S

The outlet material volume is governed not only by the air supply but
also by the material supply available at the inlet. The material supply
tubing should not be too small or restrictive. Be sure not to use hose
which might collapse.

S

Use flexible connections (such as hose) at the suction and dis-
charge, these connections should not be rigid piped and must be
compatible with the material being pumped.

S

Install a ground wire where applicable.

OPERATING INSTRUCTIONS

NOTICE

Check the tightness of the (29) tie rod nuts after

first run in period due to possible compression set of the dia-
phragm.

If retorquing is required, be sure all pressure has been re-

lieved from the pump and supply lines. Loosen (26) cap screws.
Retorque (29) flange nuts to 280 - 300 in. lbs (31.6 - 33.9 Nm). Tight-
en (26) cap screws to 120 - 140 in. lbs (13.6 - 15.8 Nm).

S

Always flush the pump with a solvent compatible with the material
being pumped if the material being pumped is subject to “setting up”
when not in use for a period of time.

S

Disconnect the air supply from the pump if it is to be inactive for a few
hours.

START-UP
1. Turn pressure control knob until motor starts to cycle.
2. Allow pump to cycle slowly until it is primed and all air is purged from

the fluid hose or dispensing valve.

3. Turn off dispensing valve and allow pump to stall - check all fittings

for leakage.

4. Adjust the regulator as required to obtain desired operating pres-

sure and flow.

SHUTDOWN

S

It is good practice to periodically flush entire pump system with a sol-
vent that is compatible with the material being pumped, especially if
the material being pumped is subject to “settling-out” when not in
use for a period of time.

S

Disconnect the air supply from the pump if it is to be inactive for a few
hours.

SERVICE

S

Certain ARO “Smart Parts” are indicated which should be available
for fast repair and reduction of down time.

S

Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirt and foreign matter during service
disassembly and reassembly.

S

Keep good records of service activity and include pump in preven-
tive maintenance program.

S

USE ONLY GENUINE ARO REPLACEMENT PARTS TO ASSURE
PERFORMANCE AND PRESSURE RATING.

S

Contact your local authorized ARO Service Center for parts and
customer service information.

S

Service Kits are available to service two separate Diaphragm Pump
functions: 1. AIR SECTION, 2. FLUID SECTION. The Fluid Section
is divided further to match typical active MATERIAL OPTIONS.

FLUID SECTION SERVICE

GENERAL SERVICE NOTES:

S

Clean and inspect each part thoroughly upon disassembly, look for
deep scratches on metallic surfaces and nicks, cuts or flat spots on
“O” rings. Replace any of the parts that are of questionable condi-
tion.

S

Upon disassembly, look for any remnants of “O” rings in the air motor
valve areas.

S

Tools required: 3/16” Allen wrench, 3/8” Allen wrench, 4 mm Allen
wrench, 6 mm Allen wrench, 7/16” wrench / socket, 1/2” wrench, 3/4”
wrench / socket, 7/8” wrench / socket, 2-1/2” wrench, 13 mm wrench
/ socket, “O” ring pick, plastic mallet and spanner wrench.

S

Loctite

R

is a registered trademark of Henkel Loctite Corporation

S

ARO

R

is a registered trademark of Ingersoll-Rand Company

S

S

271

t

and 572

t

are trademarks of Henkel Loctite Corporation

S

Содержание ARO PH10A Series

Страница 1: ...ture Limits diaphragm ball seal material Nitrile 10_ to 180_ F 12_ to 82_ C PTFE 40_ to 225_ F 4_ to 107_ C Displacement Cycle 100 psig 0 06 gal 0 23 lit Dimensional Data see page 8 Noise Level 70 psig 60 cpm 84 5 dB A j j The pump sound pressure levels published here have been updated to an Equivalent Continuous SoundLevel LAeq tomeet theintent of ANSI S1 13 1971 CAGI PNEUROP S5 1using four micro...

Страница 2: ...s tem by opening dispensing valve or device and or carefully and slowly loosening and removing outlet hose or piping from pump WARNING HAZARDOUS PRESSURE Can result in serious injury or property damage Do not service or clean pump hoses or dispensing valve while the system is pressurized WARNING HAZARDOUSMATERIALS Cancauseseriousin juryorpropertydamage Donotattempttoreturnapumptothe factory or ser...

Страница 3: ...th a solvent compatible with the material beingpumpedifthematerialbeing pumpedis subjectto settingup when not in use for a period of time S Disconnecttheairsupplyfromthepumpifitistobeinactiveforafew hours START UP 1 Turn pressure control knob until motor starts to cycle 2 Allow pump to cycleslowly untilit isprimed andall airis purgedfrom the fluid hose or dispensing valve 3 Turn off dispensing val...

Страница 4: ...er damage FLUID SECTION REASSEMBLY S Clean all parts upon reassembly Lubricate all replacement parts and metallic moving parts with Key Lube grease upon reassembly S SERVICE NOTE PTFE O rings are not resilient and they should always be replaced with new ones 1 Install the 164 back up ring by pulling it apart twist or walk it down into the cavity bottom inside the 163 bushing 2 Install the 165 quad...

Страница 5: ...ads at assembly l Apply Loctite 271 to threads at assembly m Apply anti sieze compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners ASSEMBLY NOTES n Assemble with i d chamfer against bolt head o Assemble with largest convolusion ripple towards 6 diaphragm plate Figure 2 FOR THE AIR MOTOR SECTION SEE PAGES 6 7 36 26 m 2 j 1 124 149 150 j 148 ...

Страница 6: ...DE A Aluminum C Carbon Steel SS Stainless Steel B Nitrile D Acetal T PTFE Br Brass Fg Fiberglas U Polyurethane Bz Bronze SH Hard Stainless Steel Z Zinc AIR SECTION SERVICE Service is divided into two parts 1 Pilot Valve 2 Major Valve GENERAL SERVICE NOTES S Air Motor Section Service is continued from step 8 of the Fluid Sec tion Disassembly S It is not necessary to remove the Fluid Section Ends to...

Страница 7: ...ide Clean and inspect all parts for damage and wear MAJOR VALVE REASSEMBLY S Lubricateallsoftparts spool andboreswithKey Lubegreaseupon reassembly 1 For best results rebuild the Major Valve stack one piece at a time Start with the 112 washer and install it in the side opposite the air inlet Place the washer into the bore with the raised edge facingout ward follow it with the larger 114 O ring 2 Pl...

Страница 8: ... sleeve and 2 O ring on 1 rod S Check 168 O rings on 167 pilot piston for wear Low output volume S Check air supply S Check for plugged outlet hose S For the pump to prime itself it must be mounted in the vertical posi tion so that the balls will check by gravity S Check for pump cavitation suction pipe should be 1 minimum or larger if high viscosity fluids are being pumped Suction hose must be no...

Отзывы: