background image

Page 2 of 12 

PD03P-XXX-XXX (en)

EXCESSIVE AIR PRESSURE
S TATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause per- 

sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fluid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.

WARNING

 

STATIC SPARK. Can cause explosion 

resulting in severe injury or death. Ground pump and 
pumping system.
PD03P-XDS-XXX and PD03P-XES-XXX Groundable 
Acetal pumps: Use the pump ground lug provided. 
Connect to a 12 ga. (minimum) wire (kit is included) to 
a good earth ground source.
Sparks can ignite fl ammable material and vapors.  
The pumping system and object being sprayed must be 
grounded when it is pumping, fl ushing, recirculating or 
spraying fl ammable materials such as paints, solvents, 
lacquers, etc. or used in a location where surrounding 
atmosphere is conducive to spontaneous combustion. 
Ground the dispensing valve or device, containers, hos-
es and any object to which material is being pumped.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static spark.
Consult local building codes and electrical codes for 
specifi c grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep infl ammables away from heat, open fl ames and 
sparks.
Keep containers closed when not in use.

WARNING

 

Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffl

  er.

Pipe the exhaust to a safe remote location when 
pumping hazardous or infl ammable materials.
Use a grounded 3/8” minimum i.d. hose between the 
pump and the muffl

  er.

WARNING

 

HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service 
or clean pump, hoses or dispensing valve while the 
system is pressurized.
Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.

WARNING

 

HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must comply 
with local and national laws and safety code requirements.

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.

WARNING

 

EXPLOSION HAZARD. Models containing 

aluminum wetted par ts cannot be used with 
1,1,1-trichloroethane, methylene chloride or other 
halogenated hydrocarbon solvents which may react 
and explode.
Check pump motor section, fl uid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
fl ushed or circulated. For specifi c fl uid compatibility, 
consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based 

on mechanical stress only. Certain chemicals will 
significantly reduce maximum safe operating 
temperature. Consult the chemical manufacturer for 
chemical compatibility and temperature limits. Refer 
to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, 
understand it’s limitations, and wear safety goggles / 
equipment when required.

CAUTION

 Do not use the pump for the structural 

support of the piping system. Be certain the system 
components are properly supported to prevent stress 
on the pump parts.
Suction and discharge connections should be fl exible 
connections (such as hose), not rigid piped, and should 
be compatible with the substance being pumped.

CAUTION

 Prevent unnecessary damage to the 

pump. Do not allow pump to operate when out of 
material for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.

CAUTION

 

Use only genuine ARO

®

 replacement parts to 

assure compatible pressure rating and longest service life.

NOTICE

 Install the pump in the vertical position. The 

pump may not prime properly if the balls do not check by 
gravity upon start-up.

NOTICE

  R E -TO R Q U E   A L L   FA S T E N E R S   B E F O R E 

OPERATION. Creep of housing and gasket materials may 
cause fasteners to loosen. Re-torque all fasteners to insure 
against fl uid or air leakage.

NOTICE

 Replacement warning labels are available 

upon request: Static Spark” pn \ 93616-1, Diaphragm 
Rupture” pn \ 93122.

WARNING

=

Hazards or unsafe practices which 
could result in severe personal injury, 
death or substantial property damage.

CAUTION

=

Hazards or unsafe practices which 
could result in minor personal injury, 
product or property damage.

NOTICE

=

Important installation, operation or
maintenance information.

y

y

y

y

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

Содержание ARO PD03P Series

Страница 1: ...100 to 2000 F 12 to 930 C Neoprene 00 to 2000 F 18 to 930 C Nitrile 100 to 1800 F 12 to 820 C Polypropylene 350 to 1750 F 20 to 790 C Santoprene 400 to 2250 F 400 to 1070 C PTFE 400 to 2250 F 40 to 1...

Страница 2: ...o not attempt to return a pump to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements y y y y y...

Страница 3: ...Corporation Santoprene is a registered trademark of Monsanto Company licensed to Advanced Elastomer Systems L P Lubriplate is a registered trademark of Lubriplate Division Fiske Brothers Refining Com...

Страница 4: ...Part No Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl 6 Diaphragm Nut 1 4 20 2 93810 7 P 93810 7 P 93810 3 K 93810 3 K 93810 2 D 93810 2 D 15 Fluid Cap 2 96460 1 P 96460 1 P 96460 3...

Страница 5: ...s Apply Loctite 242 to threads Apply Lubriplate 94276 to all O rings U cups and mating parts Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stain...

Страница 6: ...cket or wrench 5 16 Allen wrench T 10 Torx screwdriver torque wrench measuring inch pounds O ring pick y y y FLUID SECTION DISASSEMBLY Remove 61 top manifold Remove 19 O rings 21 seats and 22 balls Re...

Страница 7: ...111 spool LIPS MUST FACE EACH OTHER Assemble 137 O rings to 136 large plug Assemble 137 and 166 O rings to 107 small plug Insert 111 spool into 136 large plug then insert 136 large plug into 135 valv...

Страница 8: ...pe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be non collapsible type capable of pulling a h...

Страница 9: ...PD03P XXX XXX en Page 9 of 12 ACCESSORIES Figure 6 67388 WALL MOUNT BRACKET ASSEMBLY 96507 Wall Mount Bracket Y13 3 T Washer 3 3 16 Y14 10 S Lock Washer 3 10 Y154 52 S Cap Screw 3 10 24 x 1 2...

Страница 10: ...Page 10 of 12 PD03P XXX XXX en...

Страница 11: ...PD03P XXX XXX en Page 11 of 12...

Страница 12: ...Page 12 of 12 PD03P XXX XXX en PN 97999 1180...

Отзывы: