background image

5

OPERATING CONDITIONS

Operational temperature *

– 20 °C, +55 °C

Functional temperature *

– 20 °C, +65 °C

Max relative humidity

85% at 55 °C, non-condensing

Maximum backward leaning

30 degrees from vertical

*  55 °C is a maximum using temperature for user safety (IEC 60950). The product is operational up to 65 °C with no tampering issue. 

STORAGE CONDITIONS

Storage temperature

– 20 °C, +65 °C

Max relative humidity

85% at 55 °C, non-condensing

2.1.2  iUP250LE OUTPUT CONNECTORS DESCRIPTION  

LLT/Maintenance Button

COM0 & COM2 Link

USB device

Power

USB hosts

Ethernet

2 SAM

µSD

Pinshield light output

Содержание IUC150B

Страница 1: ...INTEGRATION GUIDE iSELF VENDING CLASSIC ...

Страница 2: ...WARE CHARACTERISTICS 11 2 3 4 PIN PAD AND READER iUC150B INTERCONNECTIVITY 11 3 INSTALLATION PROCEDURE IN KIOSKS 12 3 1 SECURITY REQUIREMENTS 12 3 2 GENERAL INSTALLATION RECOMMENDATIONS 12 3 3 METALIC KIOSK GROUNDING CONSIDERATION 13 3 4 PLASTIC KIOSK GROUNDING CONSIDERATION 14 4 ASSEMBLY PROCEDURE FOR THE TERMINAL 15 4 1 iUP250LE 15 4 1 1 KIOSK MINIMUM VOLUME FOR THE iUP250LE 15 4 1 2 KIOSK PREPA...

Страница 3: ...terminal solution consists of the following modules used for PIN management contact cards and contactless cards PIN pad the iUP250LE Hybrid card reader the iUR250 Contactless reader the iUC150B These compact devices are designed to fit everywhere thanks to an easy installation respectful of EVA standard iUP250 and Compact door standard iUR250 iUC150B Usage can be indoor or outdoor resisting to har...

Страница 4: ...b Flash Functionality Keys 17 metallic keys 128 64 graphic display RGB Backlight Buzzer RGB led internal status indicator 1 Maintenance Button µSD 2 SAM 1 Jack for external lighting wake up mechanism on RS232 connectors Link Ethernet 3 USB host 1 5 A total max 1 USB device 2x RS232 2 1 1 iUP250LE TECHNICAL CHARACTERISTICS The target keyboard layout of the iUP250LE has got the command keys with the...

Страница 5: ...vertical 55 C is a maximum using temperature for user safety IEC 60950 The product is operational up to 65 C with no tampering issue STORAGE CONDITIONS Storage temperature 20 C 65 C Max relative humidity 85 at 55 C non condensing 2 1 2 iUP250LE OUTPUT CONNECTORS DESCRIPTION LLT Maintenance Button COM0 COM2 Link USB device Power USB hosts Ethernet 2 SAM µSD Pinshield light output ...

Страница 6: ...klight is used to indicate the following priority information Red backlight on steady product has been tampered Key erased irruption Red backlight fl ashing slowly product is disabled Keys erased no irruption Red backlight fl ashing quickly product is out of order Commissioning needed The iUP250LE has a maintenance button on the back To enter LLT mode press the button at power up or at restart unt...

Страница 7: ...eyboard The wake up pin must be high impedance Do not connect directly any voltage on this pin even if the devices are 10 V tolerant The wake up pin is driven to 0 by the one asking the wake up It could be driven by any iSelf Series module or any devices designed to be compliant Host device The voltage on this pin must not exceed 10 V in any case As the pin is high impedance in Stand by mode any l...

Страница 8: ...to evacuate water Power supply USB 5 V 500 mA Platform Telium 2 Card interface EMV level 1 and ISO 7816 read write T 0 T 1 and synchronous cards Magnetic stripe ISO 1 2 3 read only Functionality Buzzer RGB led indicator Lever lock optional Link USB device RS232 connection only for wake up mechanism STORAGE CONDITIONS Storage temperature 20 C 65 C Max relative humidity 85 at 55 C non condensing 2 1...

Страница 9: ... is only available for debug feature and to manage wake up mechanism The connector type is RJ11 PIN No Function 1 GND Pin 6 Pin 1 2 Wake up 3 RXD not for customer use 4 RXD not for customer use 5 RXD not for customer use 6 RXD not for customer use USB DEVICE iUR25x reader unit can be connected by typ A USB WAKE UP MECHANISM iUR25x is design to save power thanks to a stand by mode To wake up iUR25x...

Страница 10: ...ver lock is controlled by application It may be used to forbid the withdrawal of the card during chip access The connection between the iUP250LE and the reader iUR250 is done through USB Red led flashing product is out of order Commissioning needed Red led flashing quickly product is out of order not compatible w iUP SW version Plug the USB cable on the iUP250LE and the iUR250 with the Ingenico st...

Страница 11: ...r Buzzer Go cless link Wake up serial link Link 1x USB device 2 3 4 PIN PAD AND READER iUC150B INTERCONNECTIVITY The connection between the iUP250LE and the reader iUC150B is done through USB Plug the USB cable on the iUP250LE and the iUC150B with the Ingenico standard USB cable USB A USB JST with the part number 296189206 30 cm included in the box or 296192761AB 1 15 m accessory USB Device Go cle...

Страница 12: ...tions Carefully consider the general and local payment security requirements and any impact they may have on the kiosk If the machine or kiosk doesn t provide such a protection an Ingenico privacy shield option can be provided The iUP250LE must be mounted on the unattended machine as indicated in the installation guide to activate the removal detectors Carefully consider the ergonomic aspects and ...

Страница 13: ...3 3 METALIC KIOSK GROUNDING CONSIDERATION All parts of the kiosk should be connected to the ground using ground cables or ground braid The devices have to be grounded according IEC 60950 Connect to ground ...

Страница 14: ...3 4 PLASTIC KIOSK GROUNDING CONSIDERATION All parts of the kiosk should be connected to the ground using ground cables or ground braid The devices have to be grounded according IEC 60950 Connect to ground ...

Страница 15: ...250LE requires minimum volume in the kiosk It includes cables and pinshield mounting 3D design on demand The minimum volume is 101 mm width 134 mm height 28 mm depth w o Ethernet connectivity 101 mm width 134 mm height 35 mm depth w Ethernet connectivity Picture showing the minimum volume for the iUP250LE ...

Страница 16: ...s are in millimeters The drawing below shows the footprint of iUP250 product CAUTION It is important that the iUP250LE footprint surface on the kiosk must be flat and cleared of any holes and burrs Special attention is required for the anti removal switch areas 3D step files are also available upon request Fixing must be done by 4 M4 16 mm welded studs Drawing of the cut out for the iUP250LE Thick...

Страница 17: ... use threadlocker fluid to prevent unscrewing with vibrations To be able to perform the commissioning procedure the PIN pad must be correctly mounted in the anti removal switch area Anti removal switch area 89 5 mm Picture showing a new installation of the iUP250 LE The outside holes on the bottom are not available for mounting Please use the inner holes at a distance of 50 8 mm 50 8 mm ...

Страница 18: ...K GROUND To insure good connexion of iUP250LE to the kiosk ground it is recommended to install one copper braid connected on one specific area and connect this braid to the chassis Torque value 1 Nm Ground studs to connect copper braid to ground ...

Страница 19: ...nt iUR250 hatched footprint surface on the kisok must be flat and clear of any holes and burrs Special attention is required for the area of the anti removal switches Fixing must be done by 4 M4 to M6 12 mm welded studs Cut out drawing for iUR250 EVA EPS compact cut out rear mounting 3D design is available on demand iUR250 footprint area iUR250 Anti removal switches area ...

Страница 20: ...tection from environment we recommend the following configurations 23 mm Vertical PIN pad above the reader Leaned backward PIN pad above vertical reader Minimum distance between reader and PIN pad is 23 mm PIN shield must be managed separately Minimum distance between reader and PIN pad is 25 mm to allow access to cables ...

Страница 21: ...d The reader can be mounted directly on the kiosk panel It requires a cut out in the kiosk to the dimensions detailed in the diagram below All dimensions are in millimeters The surface must be flat and without any burrs and without any sharp edges To fix the iUC150B four screws M4 are required The length of the screw is depending on the panel thickness or front face Installation of iUC150B Footpri...

Страница 22: ... order to avoid non voluntary contactless reading Equipment front face The length of the screws is 5 mm 0 1 mm thickness of panel The thread depth of the reader is 5 9 mm The torque is 0 6 to 0 75 Nm The dimensions of the reader iUC150B allow also mounting into the EVA EPS compact cut out rear mounting 8 cm 8 cm 8 cm ...

Страница 23: ...six payment services com worldline com 110 0613 02 CHE_EN 05 2020 YOUR LOCAL POINT OF CONTACT CAN BE FOUND AT six payment services com contacts ...