18
4.1.4 CONNECTING THE iUP250LE TO THE KIOSK GROUND
To insure good connexion of iUP250LE to the kiosk ground,
it is recommended to install one copper braid connected
on one specific area and connect this braid to the chassis.
Torque value 1 Nm.
Ground studs to connect copper braid to ground