TITAN GO Product Manual |
Product Description
INGENIA | 2022-07-14 08:35:14
16
Parameter
Valu
e
Unit
s
Notes
Temperature stabilization
time
800
s
With 0.1 ºC/W heatsink attached. Considering 90 % of the
maximum temperature.
This graphic shows the maximum current with respect to ambient temperature, also assuming a
0.1
ºC/W heatsink
attached.
4.3.3 Maximizing heat dissipation with a heatsink
A heatsink is needed to reach the nominal current at any ambient temperatures. When using high-efficiency
heatsinks or in enclosed spaces, the equation can be simplified as follows.
Current derating
The current derating graph is only indicative and is based on thermal tests performed in a climatic
chamber where there was enough room for natural air convection. Each application may reach different
ratings depending on the installation, ventilation and/or housing.
Current derating is only a recommendation and is not performed automatically by the drive.