Roadside Safety Barrier
13
Release 07/22b
Site Condition
Installation Requirements
Rock is
encountered
450mm to
600mm below
ground.
Drill a 110-300mm diameter
hole 200mm into the rock
or to a minimum total post
embedment depth of
650mm, whichever comes
first, install the post and
backfill.
Rock is
encountered
600mm to
800mm below
ground.
Drill a 110-300mm diameter
hole 50mm into the rock
or to a minimum total post
embedment depth of
800mm, whichever comes
first, and install the post and
backfill.
200
650 min.
45
0-
600
rock
soil
50
800 min.
600 – 800
rock
soil