Table 4: Installation of Ezy-Guard 4 Z-Posts in Rock
Site Condition
Installation Requirements
Rock is
encountered at
the surface.
Drill a 110-300mm diameter
hole to a depth of 450mm,
install the post in the hole
and backfill.
Rock is
encountered
within 450mm
of the surface.
Drill a 110-300mm diameter
hole 450mm into the rock
or to a minimum total post
embedment depth of
650mm, whichever comes
first, install the post and
backfill.
450
650 min.
0
-450
rock
soil
450
rock