background image

PROBLEM

WHAT TO DO 

TROUBLESHOOTING

Disconnect power and check element with ohm meter for continuity. If there 

is any continuity across the bulb, the problem is in the wiring/controls. 

Check that there is proper voltage to the heater. 

Check that the control/switch is working. 

Check main power circuit breaker. 

Check wiring for a loose connection or burned wire.

Heater does not work

A 240V element connected to 110V or 208V will warm, but not glow 

orange or generate sufficient heat for typical applications (Matching your 

voltage is extremely important). If element is visibly orange, but there is 

insufficient heat, refer to the areas covered with respect to conditions 

and mounting heights. 

Replace or clean dirty or non-reflective reflectors. 

Low heat output Heater

Heater does not glow

Check supply voltage to confirm it matches voltage of heating element. 

Unless heaters are installed over 12’ (3.7m) high, it is generally recommended that all radiant heaters be mounted 

on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and 

shoulders of the people being warmed.

When outdoors, hang heater under protective roof or weather cover 

whenever possible. Even though heater is all-weather construction, 

it will last longer and look better if it is protected from rain and snow.

Angle fixture 30º to 60º from horizontal face 

down. Best angle is approximately 45º.

Install fixture to heat the area from the “cold side” if possible. 

This helps compensate for increased body heat losses due to 

exposure. Warm floors reradiate heat. Warmer air rises from 

floor. Some heat reflects from floor. 

Mounting a heater directly over a 

table or other obstruction will block 

the energy, primarily heating the 

object. It is best to move heater to 

the side, allowing complete body 

and floor coverage.

LOCATION SUGGESTIONS

OUTDOORS

INSTALLATION DIRECTION

RECOMMENDED POSITIONING

7

alfresco-heating.com

888-Warm-Glo

Содержание SL 1612

Страница 1: ...ons 6 Trouble Shooting 7 Location Suggestions 7 Warranty 8 ALL WEATHER W SERIES AND WD SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HE TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance Instructions 6 Trouble Shooting 7 Location Suggestions ...

Страница 2: ...th the local wiring codes Do not use if the heating element is damaged or cracked 2 READ ALL INSTRUCTIONS BEFORE USING HEATER Unit may be a source of possible shock NEVER attempt to service heater without disconnecting its power source Source of possible ignition High Temperature risk of fire keep electrical cords drapery furnishings and other combustibles at least 3 0 9m from the front of heater ...

Страница 3: ...ode NEC and local codes for outdoor wiring Step 5 Use only wiring components UL CUL CE listed for outdoor use with IPX4 minimum rating INSTALLATION INSTRUCTIONS WIRING INSTRUCTIONS Connect power with flexible conduit or appropriate cord to allow heater to be swiveled The heater is drilled and threaded for standard conduit fittings The installing electrician will need to provide the appropriate rig...

Страница 4: ...is required behind the plane of the face MODEL MIN SPACING BETWEEN BRACKETS SL 16XX 12 30 5cm SL 24XX 20 50 8cm SL 30XX 30 76 2cm SL 40XX 30 76 2cm SL Series Brackets are designed for two positive stop positions The Heater can be hung in a horizontal position using chains or custom brackets The Heater must be level but can be rotated around its horizontal axis Adjustable wall ceiling brackets are ...

Страница 5: ...fail prematurely Visit infratech usa com for video instructions Need help To order replacement elements for your Infratech heating system please contact us via phone or visit our website Consult label on back of heater for proper watts voltage and replacement part number PART ELEMENT LENGTH WATTS VOLTS FITS MODELS 10 7025 E 1612 SL 22 3 8 0 6m 1600 120 SL 1612 10 7030 E 1624 SL 22 3 8 0 6m 1600 24...

Страница 6: ... x 8 2 4m x 2 4m SL 2424 2 400 7 9 2 1m 2 7m 7 x 7 2 1m x 2 1m 5 x 5 1 5m x 1 5m 9 x 9 2 7m x 2 7m SL 3024 3 000 7 9 2 1m 2 7m 8 x 8 2 4m x 2 4m 6 x 6 1 8m x 1 8m 10 x 10 3 0m x 3 0m SL 4024 4 000 8 11 2 4m 3 4m 10 x 10 3 0m x 3 0m 8 x 8 2 4m x 2 4m 12 x 12 3 7m x 3 7m MODEL WATTS MOUNTING HEIGHT AVERAGE COLD PROTECTED SL 1612 SS 1 600 6 8 1 8m 2 4m 6 x 6 1 8m x 1 8m 4 x 4 1 2m x 1 2m 8 x 8 2 4m x...

Страница 7: ...rs are installed over 12 3 7m high it is generally recommended that all radiant heaters be mounted on an angle to assure that radiant warmth is distributed from the sides rather than straight down on the heads and shoulders of the people being warmed When outdoors hang heater under protective roof or weather cover whenever possible Even though heater is all weather construction it will last longer...

Страница 8: ...ural disaster improper installation or improper operation unauthorized adjustments or calibrations dings dents scratches nor damages due to harsh chemicals i e cleaning products improperly applied Warrantor is not responsible for consequential or incidental damages Under no circumstances shall INFRATECH or any of its representatives be held liable for injury to any person or damage to any property...

Отзывы: