65
Chapter 3 – Device Profile
CD1-k – CANopen Communication Profile
Sub Index
2
Description
q-Loop Integral Gain
Data Type
Unsigned16
Object Class
pp ip hm pv eg
Access rw
PDO Mapping
No
Value Range
0..FFFFh
Default Value
eeprom
Sub Index
3
Description
d-Loop Proportional Gain
Data Type
Unsigned16
Object Class
pp ip hm pv eg
Access rw
PDO Mapping
No
Value Range
0..FFFFh
Default Value
eeprom
Sub Index
4
Description
d-Loop Integral Gain
Data Type
Unsigned16
Object Class
pp ip hm pv eg
Access rw
PDO Mapping
No
Value Range
0..FFFFh
Default Value
eeprom
3.10.2.5 - Object 6078h: Filtered current monitor
This object is the filtered motor current monitor. This monitor is calculated with vector transformation. This means
that the current monitor is correct only if the motor position is correct (no motor sensor error...).
Index 6078h
Name
Filtered Current Monitor
Object Code
VAR
Data Type
Integer16
Object Class
all
Access ro
PDO Mapping
Possible
Unit
per thousand of amplifier Rating
3.10.2.6 - Object 3078h: Current monitor filter
This object defines the time constant value for the first order filter acting on the motor current monitor (see object
6078h) .
Index 3078h
Name
Current Monitor filter
Object Code
VAR
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
no
Unit micro-seconds
Range
500 to 10 000
Default value
4000