91
CD1-k – CANopen Communication Profile
Chapter 3 – Device Profile
Sub Index
4
Description
Encoder Output Zero Pulse Shift
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Value Range
0..32768
Default Value
eeprom
The
Encoder Output Zero pulse shift
parameter allows to shift the marker pulse position on channel Z with
regard to the motor zero position given by the position sensor. The value 32767 corresponds to one motor shaft
revolution. The marker pulse width is equal to 1/4 of the A and B channels period.
Sub Index
5
Name
Enable / Disable Encoder Output
Object Code
VAR
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
0
Value Description
0
Encoder Output disabled on the CD1-k X3 connector
1
Encoder Output enabled on the CD1-k X3 connector
At the CD1-k amplifier power up, the encoder output is always disabled.
Remarks: The TTL encoder input lines and the encoder output lines are located at the same pins number on the
CD1-k X3 connector. So, when the encoder output is enabled, the TTL encoder input cannot be used.
Sub Index
6
Description
Encoder Output Programming Procedure
Data Type
Unsigned16
Object Class
all
Access wo
PDO Mapping
No
The Programming procedure modifies the encoder emulation output according to the parameters defined by
object 3086 subindex 1, 2, 3, 4. The procedure is only executed if a 1 is written to this object.