GD1 – Installation Guide
11
Part 1 –
Chapter 1 – General description
X
CALCULATION OF THE AVERAGE RATED POWER OF THE APPLICATION
:
1.3 – COMMUNICATION INTERFACES
The standard version of the GD1 is delivered with the CANopen
communication interface. But this drive is also
available with other interfaces.
1.4 – PROTECTIONS
(according to EN 954-1 standard)
Safe torque off (see appendix)
1.5 – PROGRAMMABILITY
Servo functions
User program (
1.6 – COMPLIANCE WITH THE STANDARDS
1.6.1
–
G
ENERAL DESCRIPTION
The supply of the DC/DC converter requires an auxiliary 24 V /-15%. A 24 V
DC
battery supply with
specific wiring allows to keep the position even after switching off the auxiliary 24 V
DC
supply.
The power supply is depending on the drive type:
♦
GD1-230/05 A to 30 A
: integrated 230 V
AC
single-phase mains operated power supply
♦
GD1-400/05 A to 20 A
: integrated 230 to 480 V
AC
three-phase mains operated power supply
♦
GD1-400/30 – 45 – 60 - 90 A
: 230 to 480 V
AC
three-phase mains operated supply with external power
supply unit GDPS-400
An integrated soft start system of the power supply limits the inrush current at power on.
The small dimensions of the GD1 drive allow an optimum integration:
♦
in 300 mm deep cabinets (connectors included) when fastened on the cabinet rear wall,
♦
in 240 mm deep cabinets with wall-crossing fastening (
see diagram in chapter 2, section 2.2
♦
Mounting pitch: 74.5 mm up to a current rating of 45 A and double-pitch for higher currents (60 A and 90 A).
Содержание GD1-400/05
Страница 1: ...GD1 INFRANOR Gem Drive Installation Guide gb Actuator ...
Страница 5: ...4 Part 1 GD1 amplifier GD1 Installation Guide PART 1 ________ GD1 AMPLIFIER ...
Страница 40: ...GD1 Installation Guide 39 Part 2 GDPS power supply PART 2 ________ GDPS POWER SUPPLY ...
Страница 49: ...48 Part 2 Chapter 4 Order code GD1 Installation Guide PART 3 ________ APPENDIX ...