Parameter Description
Parameter Description
SIO Port, Type
Socket port of
serial I/O, Type
¾
The local port number of the WM-112 converter to be
contacted by other devices. The default value is 9925. And
users need to choose one communication mode for the
WS-100 converter. There are four different communication
modes can be selected. They are TCP Server, TCP Client,
UDP Server and UDP Client.
¾
TCP Server – The WM-112 converter will operate at the
Passive or the TCP listen mode to receive TCP connection
requests from the remote client device.
¾
TCP Client – The WM-112 converter will operate at the
Active or the TCP Active mode to request establishing a
TCP connection with the remote server device.
¾
UDP Server – The WM-112 converter will operate at the
UDP Server mode to send and receive UDP datagram
to/from the remote device.
¾
UDP Client – The WM-112 converter will operate at the
UDP Client mode to send and receive UDP datagram
to/from the remote device specified in Remote Host IP
address and Remote Host Port.
¾
NOTE: SIO port number 502 is reserved for the
Modbus/TCP protocol. When user connects the serial
Modbus device running in Modbus/RTU Slave mode, the
WM-112 converter can receive connection requests from
Modbus/TCP Master device. Also when user connects the
serial Modbus device running in Modbus/RTU Master
mode, the WM-112 converter can connect to Modbus/TCP
Slave device.