background image

46

7.7 How to Read Small-sized DM Barcode and the
Defaced Barcode

Small DM reading optimization
In the settings window find Decoding settings, turn on the Small DM reading optimization
and set the download.

Small DM reading optimization close

Small DM reading optimization open

Содержание FV10X Series

Страница 1: ...infoscan FV10X series Operating Manual NANJING BILIN INTELLIGENT IDENTIFICATION TECHNOLOGY COLTD www infoscan com cn Tel 0086 400 700 6288 Ver 20220428...

Страница 2: ...ostepper Online Operation 16 5 Quick Setup FV105 without infostepper 18 6 How to Set up FV10X with infostepper 19 6 1 Focusing on Adjustment 19 6 2 Getting a Clear Image 20 6 3 Image Parameters Settin...

Страница 3: ...5 7 7 How to Read Small sized DM Barcode and the Defaced Barcode 46 7 8 How to Use the Polling Algorithm for Complicated Reading Applications 48 8 Other Operations 49 8 1 To View Decoded Data after On...

Страница 4: ...nual the FV105 model is used as an example and the differences between the FV104 and FV105 are described and explained in remarks 1 Check packaging and the belongings 2 Wiring and installation 3 Conne...

Страница 5: ...4 1 Unwrapped the Package 1 1 Scanner and its belonging Model Name Package content Quantity Picture FV10X Industrial scanner Scanner 1 Quick use guide 1 Fixed piece 1 Insulating gasket 1 Screw 5...

Страница 6: ...t communication cable H8S 2M RJ V1 1 Power Power adapter WT48 2402000 T 1 1 Camers lens 2 Laser aimer 3 Array LED light source 4 12PIN aviation jack serial communication power supply I O 5 8PIN aviati...

Страница 7: ...6 1 4 Configuration Connection diagram Data communication Ethernet USB RS322 Ethernet I O USB...

Страница 8: ...y 2 Rotate the aviation plug male screw clockwise to fix it After the aviation cable plug male is firmly connected with the equipment the serial communication cable DB9 female is connected to the PC s...

Страница 9: ...to 20 30V for power supply 2 GND GND GND 3 IN1 input signal 1 Logic level default low level takes effect 4 IN2 input signal 2 Logic level default low level takes effect 5 GND GND GND 6 COM Voltage ou...

Страница 10: ...faults to the initial logic Take the push button switch as an example connect the switch to signal terminals 2 and 3 When the switch is pressed the trigger takes effect The line sequence is shown in t...

Страница 11: ...of line sequence is as follows Note The maximum working current of the output load is 400mA Consult technical support for other currents 2 External load relay feedback wiring The device defaults to t...

Страница 12: ...ustment 3 1 Before installation Before installation please pay attention to the following items and check the installation conditions 1 No influence of ambient light Please avoid sunlight other lighti...

Страница 13: ...ounting configuration is shown in the figure The mounting position of the L shaped metal fixing plate can be adjusted according to the actual needs the picture is FV104 3 3 Angle adjustment As shown i...

Страница 14: ...13 3 4 Product Dimensions FV105 Rotate 90 Note FV104 size is the same as FV105 size Unit mm...

Страница 15: ...0bit 52 1090 15mil Code 128 10bit 65 380 15mil Code 128 10bit 90 1090 5mil DataMatrix 10bit 25 100 5mil DataMatrix 10bit 45 125 6 67mil DataMatrix 10bit 25 100 6 67mil DataMatrix 10bit 45 175 10mil Da...

Страница 16: ...p the compressed package and run infostepper exe 4 1 Introduction to infostepper module serial number illustrate 1 Common Toolbar 2 Connection method and connection information display 3 Online feedba...

Страница 17: ...the device as shown in the figure Click Connect to device after the connection is successful the device will have a buzzer prompt as shown in the figure Note Displays information such as the model nam...

Страница 18: ...ce select EthernetSettings select the computer network card and click Search Device as shown in the figure Click Connect to device after the connection is successful the device will have a buzzer prom...

Страница 19: ...uning are indicated by a buzzer and an indicator light The success of automatic parameter adjustment is closely related to the quality of the barcode of the sample read Under the condition of good qua...

Страница 20: ...tured images The sample captured image is blurry which affects decoding then the focus parameters of the code reader need to be adjusted Display scale can be adjusted according to need 4 Method 2 clic...

Страница 21: ...tiple recommended parameters you can click the drop down to select 4 After the auto focus is successful enter the continuous viewing mode directly In the example shown in the figure the barcode area o...

Страница 22: ...st the sharpness flexibly Note The above operations can complete the setting of the barcode reader to focus on the image clearly FV104 is a manual focus type code reader You can use the Allen key to r...

Страница 23: ...ess will also change significantly the image contrast will change significantly For static barcode reading applications the exposure time has little effect on the reading success rate if the mobile re...

Страница 24: ...Stop bits can all be set according to requirements Take the baud rate setting as an example set the baud rate to 9600 select 9600 and click the OK button 3 Click Download Configuration if the setting...

Страница 25: ...The selected Parity setting appears in the setting list just click Download Configuration 5 select Data bits Stop bits according to your needs then click the OK button The selected Data bits Stop bit...

Страница 26: ...tly entered by keyboard according to requirements 3 After the IP address input is completed click the Confirm button the set IP address will be displayed in the list click the Set Download button the...

Страница 27: ...signal level is 24V 2 IO output logic OUT1 OUT2 output level signals are all 24V 3 The default IO output logic OUT1 is read success OUT2 is read failure the output level signal pulse width of read su...

Страница 28: ...ng 6 8 The Buzzer and Laser Aiming Function Setting for Success or Failure of Barcode reading 1 When the FV105 code reader succeeds in reading the code or fails in the code reading the buzzer and the...

Страница 29: ...ation command hex is 544F4646 2 Set the trigger command for example set LON as the trigger command select Transformation Assistant and input LON to convert LON to the corresponding hexadecimal 3 Copy...

Страница 30: ...failure feedback is closed by default 2 The read failure feedback switch is set to on and the read failure character feedback character hex is set to NoRead Use the conversion assistant to convert NoR...

Страница 31: ...arcode shielding function is off by default and repeat shielding time is 0 S by default 2 Repeat barcode shielding is set to open repeat shielding time is set to 5 3 The repetition masking time is set...

Страница 32: ...code filtering function which can be set according to the code system the number of characters special characters etc to achieve this function 2 For example if the output code symbology is QR barcode...

Страница 33: ...nductive reading mode is off by default 2 If the induction trigger is set to open you can set the induction trigger lighting intensity induction pause time grayscale frame moving speed etc 3 The induc...

Страница 34: ...and high frequency motion reading applications the enhanced mode can be the best choice 2 The default value of the maximum number of images captured in enhanced mode is 10 and the value is 1 20 which...

Страница 35: ...can be selected 2 The startup mode of continuous trigger mode is divided into boot startup and I O trigger the default is I O trigger 3 Continuous trigger mode shooting interval time The default valu...

Страница 36: ...mum amount of light entering The default value is 50 and the value range is 0 100 which can be adjusted according to actual application requirements 2 Automatic parameter adjustment speed The default...

Страница 37: ...system on After checking set the download you can open all code Full code system off After checking set the download you can turn off all code A code system can be turned on or off seperately and eac...

Страница 38: ...indow obtain you can view the latest image successful decoding image and failed decoding image set Last Image The last image taken by the reader success failure Decoding success image the image the ba...

Страница 39: ...th successful settings click Generate configuration barcode 2 According to the prompt it can be pasted into the word file or viewed in the image window the picture is viewed in the image interface and...

Страница 40: ...the setting window click to save the current device configuration to the local storage 2 Click Open Device Configuration select the corresponding configuration file then the parameters of the saved co...

Страница 41: ...ulti Barcode rules you can set multiple barcode rules Number of barcodes read The number of read barcodes can be set according to specific application requirements When the quantity is set to 0 all ba...

Страница 42: ...g the box with the mouse selection function the current address information will be automatically updated to the multiple barcode rules as shown in the figure To set the second barcode set the output...

Страница 43: ...haracters to be matched Select the characters to be used as barcode rules Note There are new rules that need to be added to the rule table compiled and written then the matching rules will take effect...

Страница 44: ...n the barcode editor Confirm compile write As shown in the figure the barcode information prefix and suffix are ABC In the multi barcode mode suffixes can also be added to multiple different barcodes...

Страница 45: ...modified I O logic needs to be clicked to compile then it will take effect after writing Load Initial Logic Rule Restore Factory 7 5 How to Read a Color inverted Barcode In the settings window find D...

Страница 46: ...to Read the Dot matrix Barcode In the settings window and find Decoding settings turn on the Dot matirx code optimization and set the download Dot matirx code optimization close Dot matirx code optimi...

Страница 47: ...ode and the Defaced Barcode Small DM reading optimization In the settings window find Decoding settings turn on the Small DM reading optimization and set the download Small DM reading optimization clo...

Страница 48: ...M reading optimization In the settings window and find Decoding settings turn on the Defaced DM reading optimization and set the download Defaced DM reading optimization close Defaced DM reading optim...

Страница 49: ...sets of parameters can be set When setting you need to confirm the setting of the corresponding imaging parameter group The parameter group is 1 4 The default is a set of parameter groups that is the...

Страница 50: ...to Trigger FV10X with Commands In the data window select the corresponding command and click Send Command to trigger the device The device trigger command is TON by default and the cancel trigger com...

Страница 51: ...the serial communication cable and the USB end to the PC end In the communication settings the baud rate is set to 9600 and the download can be set Data output is keyboard input and data can be viewe...

Страница 52: ...51 8 4 How to Check the Firmware Version Information of the Reader Click the Help button and click E equipment Information to view the current device model firmware version number etc...

Страница 53: ...ter hearing the device beep and seeing the success message the device has been restored to the factory state successfully 8 6 How to Convert Characters to Hex Code Click the Transformation assistant e...

Страница 54: ...canceled by default TOFF 544F4646 Default reading failure character feedback Closed NR 4E52 Default transmission delay 0 S Decoding time symbology information barcode position closure Default duplica...

Страница 55: ...er languages can be used after familiarizing with the device operation Refer to the relevant data sending and receiving code of the serial port TCP debugging assistant to write 10 1 RS232 Communicatio...

Страница 56: ...ived byte buffer new byte serialPort1 BytesToRead int len serialPort1 Read buffer 0 buffer Length Console WriteLine Encoding ASCII GetString buffer 0 len By default the barcode data is uploaded as it...

Страница 57: ...ily InterNetwork SocketType Stream ProtocolType Tcp _mySocket Connect IPAddress Parse 192 168 0 100 4096 2 Send trigger command The trigger command defaults to TON Sending trigger commands only requir...

Страница 58: ...rue TRec Start A loop is opened in the thread to continuously detect whether there is data that needs to be read if _mySocket Available 0 Continue If there is read the data and process it byte buffer...

Отзывы: