background image

I n t r o d u c t i o n 

The Vega patio heater produces radiant heat like the sun, warming people and objects and not the air in between, providing 

the only form of heat that will not blow away. The Vega is primarily designed for outdoor use within domestic applications and 

is therefore weatherproof. 

 

Please read the following instructions carefully before use. The safety of this heater is guaranteed only by its correct 

usage in accordance with these instructions, therefore it is recommended that they are retained for future reference. 

 

C a u t i o n 

 

Before using this appliance: 

 

Check that the voltage indicated on the type plate corresponds to the mains supply voltage. 

Ensure that the heater has been securely fastened in its final mounting position. 

Disconnect the power during installation, cleaning and/or filament replacement and ensure  

         that the filament is cool. 

Do not handle the filament with bare hands. If it is inadvertently touched, remove finger marks 

         with a soft cloth and methylated spirit or alcohol, otherwise the marks will burn into the quartz,  

         causing premature heater failure. 

Touch the front glass as little as possible in order to avoid unsightly grease residue. 

Do not use an extension cable with this product. 

Keep the mains cable away from the body of the heater which will get hot during use. 

Do not cover or obstruct the heater when in use. 

Ensure that children do not tamper with the heater. 

Do not insert any object through a slot or opening in the heater. 

Do not use if glass is broken. 

For the US/Canada - Use only on 15 ampere branch circuit. 

Do not install less than 2.3m (7’7”) from the floor. 

 

R i s k   o f   f i r e 

 

Keep combustible materials such as furniture, papers, clothes and  

curtains at least 3 feet (0.9m) from the front of the heater and  

away from the sides and rear. If the heater is to be used outside,  

we recommend that a waterproof or indoor socket is used.

 

 

Specification 

VEGA 

VEGA USA 

Voltage (V) 

230 

120 

Total power (kW) 

1.3 

1.2 

Phase supply  

1(230V) 

1(120V) 

Amps per phase (A) 

5.7 

10 

Minimum mounting height from floor  

2.3m 

7’ 7’’ 

Minimum distance from ceiling  

0.5m 

1’ 7’’ 

Minimum distance from side wall  

1.5m 

4’ 11’’ 

Dimensions W x H x D  

410mm x 210mm x 130mm 

16 ’’ x 8¼’’ x 5”

 

Weight  

2.85kg 

6

1/4 

lb 

Insulation class 

Ingress protection 

IP54 

IP54 

* All measurements are nominal and subject to change without prior notification 

0.9m 

2.8m (9’ 2’’) 

2.8m (9’ 2’’) 

2.

8m

 (

9’

 2

’’)

 

8m

2

 

2.

3m

 (

7’

 7

’’)

 

M

in

im

um

 m

ou

nt

in

he

ig

ht

 

I n s t a l l a t i o n  

   

W i r i n g  

Warning - this appliance must be earthed or grounded. 
The wired versions (VEGA and VEGA USA) are fitted with 5 metres (16’5”) of supply cable and a moulded plug, 

therefore it is unnecessary to remove the terminal box in order to carry out normal installation of these models. 
All installations (wired and unwired) must be carried out by a suitably qualified electrician, following the instruction 

below, in accordance with relevant local safety regulations. 
We recommend using a RCD or GRD where applicable. 
If  the  supply  cord  becomes  damaged,  it  must  be  replaced  by  the  manufacturer,  its  service  agent  or  a  similar 

qualified person in order to avoid a hazard. 
When the electrical connection is outside, it is recommended that a waterproof socket is used for the connection/

terminal. Otherwise, the plug should be connected to a socket indoors. 
If in any doubt, please contact a suitably qualified electrician. 

 

1. 

Disconnect power.  Unscrew the terminal box cover at the back of the 

heater and feed the supply cable through the compression gland. 

 

2. 

Use a heat resistant supply cable with 2 poles and earth. The live and 

neutral wires must be covered with the protective silicon casing provided 

before connection to the terminal block. See Fig 1. 

 

3. 

The  green/yellow  wire  should  be  connected  to  the  clamp  marked  with 

the earth or ground symbol.  

 

4. 

Tighten the barrel nut of the compression gland so that the rubber seal 

grips  the  cable.  The  seal  can  be  adjusted  to  accommodate  cables  of 

diameter between 8mm and 11mm (approx  ’’). See Fig 2. 

 

5. 

Ensure that the cover is secured well in order to prevent water ingress.  

M o u n t i n g 

 

1. 

Separate the heater from the mounting bracket by loosening the 2 nuts 

on the back of the heater. 

 

2. 

Securely  fasten  the  bracket  to  the  mounting  surface  using  the  fixing 

holes  in  the  mounting  bracket.  The  torque  of  the  bracket  fastening 

screws must be at least 8 Nm. 

 

3. 

Replace the heater on the bracket using the nut and bolt supplied (Fig 4 

and  5)  and  fix  at  the  required  angular  position  by  tightening  the  fixing 

bolt (Fig 3).  

 

The  heater  must  be  mounted  in  such  a  way  that  the  halogen  emitter 

does not slant more than 4° from the horizontal (when viewed from the 

front of the heater).
Allow  the  heater  to  cool  before  attempting  to  reposition/move.  Never 

attempt to move the heater while it is switched on. 
The  heater  is  suitable  for  installation  on  a  normally  non-flammable  

surface. Observe the minimum safe distance between the heater body 

and inflammable surfaces when mounting. 
Please refer to Table 1 for the recommended positioning of the heater. 
Keep out of the reach of children. 

Fig 1  

Fig 2  

Fig 3 

0.5m (1’7 ”) 

50mm (2”) 

50° 

Fig 4 

Fig 5  

Отзывы: