2. Fix  the  heater  assembly  to  the  brackets 

via  the  hole  in  the  centre  of  the    joining 
bar. The joining bars should slide inside 
the gap of the two wall brackets. 

 
3. Place  a  bolt  and  washer  in  the  hole  of 

the  wall  bracket  and  put  a  serrated 
washer  on  the  opposite  side  between 
the  bracket  and  joining  bar.  Repeat  on 
opposite side. 

1. Securely fasten the L-shaped wall brackets to the mounting surface using both of the fixing 

holes  in  the  short  part  of  the  bracket  (see  Fig.  H  for  mounting  hole  template  centres). 
Please  refer  to  Table  1  for  recommended  positioning  of  the  heater.  Please  note.  wall       
fixings are not supplied. They should be selected to substantially support the weight of the 
installation. If in doubt contact a professional for advice! 

When  two  Alpha  H1  heaters  are  joined  they  can  also 
be chain hung from a ceiling (Fig. J). 

 

Please  refer  to  Table  1  for  the  recommended            
positioning  of  the  heater  with  regards  to  minimum    
distances. Do not install the heater in a corner! 

 

Always  allow  the  heater  to  cool  before  attempting  to 
reposition/move.  Never  attempt  to  move  the  heater 
while it is switched on! 

 

continued on next page… 

 

Fig. H 

DRILLING HOLE TEMPLATE DIMENSIONS 

FOR WALL MOUNTED BRACKETS 

C H A I N   H A N G I N G  - T W O   S I N G L E   H E AT E R S   J O I N E D

 

Fig. J 

S

E

E

 T

A

B

L

E

 1

 F

O

R

 M

IN

IM

U

M

 

D

IM

E

N

S

IO

N

S

 

4. Fit  the  heater  assembly  to  the  brackets  and  place  a  washer  and  nut  on  the  bolts           

protruding through the joining bars. 

 
5. Fully tighten the nut and bolts (Fig. G) with the heaters set as shown in Fig. F. 
 
6. Secure the supply cables so they do not rest on the body or obstruct air-vents. 
 

Always isolate the heater from the mains supply when adjusting the angular position.

 

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N  

Switch off/unplug the heater from the mains supply 
when mounting or adjusting the heater position.

 

Содержание SALPHA10240

Страница 1: ...8 240V 1500 2000W INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Ontario L4Z 2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE 247748 WEATHERPROOF INFRARED HEATERS SUITABLE FOR OUTDOOR AND INDOOR USE RESIDENTIAL COMMERCIAL AND INDUSTRIAL EN ...

Страница 2: ...ont of the heater and keep them away from the sides and rear 4 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 5 Always unplug the 120 volt heater when not in use 6 Do not operate any heater with a damaged cord or plug or after the heater malfunctions has been dropped or damaged in any manner Return heate...

Страница 3: ...t use it in areas where gasoline paint or flammable liquids are used or stored 14 Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire 15 Do not cover or otherwise obstruct the heater 16 Do not touch the heater during operation as the body becomes very hot and cause burns Particular attention has been given where children and vulnerable people are pre...

Страница 4: ... emitter is cool before handling 12 Do not handle the halogen emitter with bare hands If it is inadvertently touched remove finger marks with a soft cloth and methylated spirit or rubbing alcohol Otherwise the marks will burn into the quartz emitter during use causing premature heater failure 13 The heater is not intended for use by young children and must be supervised by a responsible person at ...

Страница 5: ...5 1500 1500 2000 1500 2000 2250 3000 3000 4000 2250 3000 3375 4500 4500 6000 Current Amps per Emitter 12 5 3 6 4 2 5 4 6 3 7 2 8 3 3 6 4 2 5 4 6 3 7 2 8 3 3 6 4 2 5 4 6 3 7 2 8 3 Total Current Amps of Unit 12 5 3 6 4 2 5 4 6 3 7 2 8 3 7 2 8 3 10 8 12 5 14 4 16 7 10 8 12 5 16 2 18 8 21 6 25 0 Min Mounting Height From Floor 79 in 201 cm 98 in 108 in 250 cm 274 cm 108 in 120 in 250 cm 305 cm Min Dist...

Страница 6: ...le and a molded 3 pin 15 amp plug The 208 240V version of the heater is fitted with 2 x supply cords measuring 79 inches 200 cm for hard wiring WARNING Wiring procedures and connections should be in accordance with the National Electric Code NEC and local codes WARNING If the supply cord becomes damaged it must be immediately replaced by a qualified person in order to avoid a hazard CAUTION Discon...

Страница 7: ...ter Please note wall fixings are not supplied They should be selected to substantially support the weight of the installation If in doubt contact a professional for advice When hanging from a ceiling two equal length and gauge chains are required and should be selected with fixings that are adequate to hold the weight of the heater Again if in doubt contact a professional for advice 2 The heater s...

Страница 8: ...shers and nuts 7 Again ensuring the heaters remain flat fully tighten all four nuts to secure the joining bars in place When wall mounting two Alpha H1 heaters joined together in a horizontal manner do not position the heater at an angle more than 50 and less than 30 as shown in Fig F Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is ...

Страница 9: ...y can also be chain hung from a ceiling Fig J Please refer to Table 1 for the recommended positioning of the heater with regards to minimum distances Do not install the heater in a corner Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is switched on continued on next page Fig H DRILLING HOLE TEMPLATE DIMENSIONS FOR WALL MOUNTED BRACKE...

Страница 10: ...on the rear heaters and slide a shake proof washer on all the threads from the protruding side 4 Slide the joining bars on each bolt and fit a washer and nut do not fully tighten at this point 5 Position the second heater so it s parallel to the first and sitting flat 6 Take the third heater and a joining bar Push a bolt and washer through the end hole and place a serrated washer on the other side...

Страница 11: ...he heater Please note wall fixings are not supplied They should be selected to substantially support the weight of the heater assembly If in doubt contact a professional for advice 2 The heater assembly should be mounted with the terminal boxes positioned at the bottom of the heaters 3 Fix the heater assembly to the brackets via the bolt threads on the middle heater A serrated washer should be pla...

Страница 12: ...y faces directly down when hanging 3 Secure the supply cables so they do not rest on the body or obstruct the air vents Fig M SEE TABLE 1 FOR MINIMUM DIMENSIONS Observe the minimum safe distance between the heater body and inflammable surfaces and objects when mounting Please refer to Table 1 for the recommended positioning of the heater with regards to minimum distances Do not install the heater ...

Страница 13: ...tor quoting model type and rating from rating label It is very important that your replacement emitter is exactly the same as the one it was supplied with Failure to fit the exact same type can cause the heater to prematurely fail Unplug switch off from the mains to the heater or heater assembly power before any attempts are made to replace the emitter Contact your distributor for the correct repl...

Страница 14: ...flector up and away from the heater Repeat at the opposite end to remove other side reflector 8 The emitter wires should be pulled out of the side slots Fig U and the emitter can be lifted up completely The wires can then be gently pulled forward so that they come out from behind the reflector SCREW Fig U 5 Pull the emitter wires one at a time through the plate to remove as shown in Fig R Fig Q Fi...

Страница 15: ...r screws Before any other parts are fitted to make sure emitter is held safely Fig V W AL L M O U N T E D C O N F I G U R AT I O N S AT A G L AN C E 1 x Alpha H1 Unit 2 x Alpha H1 Units 3 x Alpha H1 Units 9 The emitter can now be removed away from the heater leaving it ready to have the new emitter fitted as shown in Fig V 15 ...

Страница 16: ...its INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Ontario L4Z 2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com Due to our policy of ongoing improvement we reserve the right to make changes without notice 2013 INFORESIGHT CONSUMER PRODUCTS INC Ref No 042224 Issue No 3 247748 ...

Отзывы: