Before using this appliance: 

 

1.      Check  that  the  voltage  indicated  on  the  units  rating  label  corresponds  to  the  mains     
         supply voltage. 

 

2.

Do not install the heaters less than the minimum height from the floor as specified below 
in the specification - Table. 1. 

 

3.      Ensure that the heater has been securely fastened in its final mounting position. 

 

4.     

WARNING 

- This appliance must be grounded! 

 

5.     

WARNING 

- Keep the mains  cord away from the body of the heater  which  will get hot 

         during use. 

 

6.

If a socket outlet is used do not position the outlet immediately behind the heater. 

 

7.      Avoid the use of an extension cord with this product. 

 

8.      Do not cover or obstruct the heater while it is in use. 

 

9.      Do not insert any object through any slot or opening in the heater. 

 

10. Do not use if guard is not present. 

 

11.   

WARNING

 - When replacing the emitter or cleaning the unit, ensure that the 3-pin 120 

         volt plug is removed from its socket outlet or if hard wired circuit is disconnected from the 
         mains supply. 

Note

: always ensure that the emitter is cool before handling. 

 

12. Do  not  handle  the  halogen  emitter  with  bare  hands.  If  it  is  inadvertently 

touched,  remove  finger  marks  with  a  soft  cloth  and  methylated  spirit  or      
rubbing alcohol. Otherwise, the marks will burn into the quartz emitter during 
use causing premature heater failure. 

 

13.    The  heater  is  not  intended  for  use  by  young  children  and  must  be  supervised  by  a       
         responsible person at all times. 

 

14.    Always remove the 3-pin 120 volt plug on the 120 volt heater if it is not being used. 

C A U T I O N

C A U T I O N

C A U T I O N

C A U T I O N  

I N T R O D U C T I O N

 

 

The Alpha H1 heater produces radiant heat like the sun, warming people and objects rather 
than  the  air  in  between.  It  is  mounted  on  an  adjustable  bracket  that  allows  the  heat  to  be     
directed exactly where it is required. The Alpha H1 can also be used in a modular system in 
that more than one heater can be joined together - see ‘Configurations’ later in the manual. 
The Alpha H1 weatherproof heater is designed for indoor and outdoor use. 
 

Please read the following instructions carefully before use. The safety of this heater is      
guaranteed only by its correct usage in accordance with these instructions, therefore 
they should be retained for future reference.

 

Содержание SALPHA10240

Страница 1: ...8 240V 1500 2000W INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Ontario L4Z 2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com IMPORTANT SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE 247748 WEATHERPROOF INFRARED HEATERS SUITABLE FOR OUTDOOR AND INDOOR USE RESIDENTIAL COMMERCIAL AND INDUSTRIAL EN ...

Страница 2: ...ont of the heater and keep them away from the sides and rear 4 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 5 Always unplug the 120 volt heater when not in use 6 Do not operate any heater with a damaged cord or plug or after the heater malfunctions has been dropped or damaged in any manner Return heate...

Страница 3: ...t use it in areas where gasoline paint or flammable liquids are used or stored 14 Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire 15 Do not cover or otherwise obstruct the heater 16 Do not touch the heater during operation as the body becomes very hot and cause burns Particular attention has been given where children and vulnerable people are pre...

Страница 4: ... emitter is cool before handling 12 Do not handle the halogen emitter with bare hands If it is inadvertently touched remove finger marks with a soft cloth and methylated spirit or rubbing alcohol Otherwise the marks will burn into the quartz emitter during use causing premature heater failure 13 The heater is not intended for use by young children and must be supervised by a responsible person at ...

Страница 5: ...5 1500 1500 2000 1500 2000 2250 3000 3000 4000 2250 3000 3375 4500 4500 6000 Current Amps per Emitter 12 5 3 6 4 2 5 4 6 3 7 2 8 3 3 6 4 2 5 4 6 3 7 2 8 3 3 6 4 2 5 4 6 3 7 2 8 3 Total Current Amps of Unit 12 5 3 6 4 2 5 4 6 3 7 2 8 3 7 2 8 3 10 8 12 5 14 4 16 7 10 8 12 5 16 2 18 8 21 6 25 0 Min Mounting Height From Floor 79 in 201 cm 98 in 108 in 250 cm 274 cm 108 in 120 in 250 cm 305 cm Min Dist...

Страница 6: ...le and a molded 3 pin 15 amp plug The 208 240V version of the heater is fitted with 2 x supply cords measuring 79 inches 200 cm for hard wiring WARNING Wiring procedures and connections should be in accordance with the National Electric Code NEC and local codes WARNING If the supply cord becomes damaged it must be immediately replaced by a qualified person in order to avoid a hazard CAUTION Discon...

Страница 7: ...ter Please note wall fixings are not supplied They should be selected to substantially support the weight of the installation If in doubt contact a professional for advice When hanging from a ceiling two equal length and gauge chains are required and should be selected with fixings that are adequate to hold the weight of the heater Again if in doubt contact a professional for advice 2 The heater s...

Страница 8: ...shers and nuts 7 Again ensuring the heaters remain flat fully tighten all four nuts to secure the joining bars in place When wall mounting two Alpha H1 heaters joined together in a horizontal manner do not position the heater at an angle more than 50 and less than 30 as shown in Fig F Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is ...

Страница 9: ...y can also be chain hung from a ceiling Fig J Please refer to Table 1 for the recommended positioning of the heater with regards to minimum distances Do not install the heater in a corner Always allow the heater to cool before attempting to reposition move Never attempt to move the heater while it is switched on continued on next page Fig H DRILLING HOLE TEMPLATE DIMENSIONS FOR WALL MOUNTED BRACKE...

Страница 10: ...on the rear heaters and slide a shake proof washer on all the threads from the protruding side 4 Slide the joining bars on each bolt and fit a washer and nut do not fully tighten at this point 5 Position the second heater so it s parallel to the first and sitting flat 6 Take the third heater and a joining bar Push a bolt and washer through the end hole and place a serrated washer on the other side...

Страница 11: ...he heater Please note wall fixings are not supplied They should be selected to substantially support the weight of the heater assembly If in doubt contact a professional for advice 2 The heater assembly should be mounted with the terminal boxes positioned at the bottom of the heaters 3 Fix the heater assembly to the brackets via the bolt threads on the middle heater A serrated washer should be pla...

Страница 12: ...y faces directly down when hanging 3 Secure the supply cables so they do not rest on the body or obstruct the air vents Fig M SEE TABLE 1 FOR MINIMUM DIMENSIONS Observe the minimum safe distance between the heater body and inflammable surfaces and objects when mounting Please refer to Table 1 for the recommended positioning of the heater with regards to minimum distances Do not install the heater ...

Страница 13: ...tor quoting model type and rating from rating label It is very important that your replacement emitter is exactly the same as the one it was supplied with Failure to fit the exact same type can cause the heater to prematurely fail Unplug switch off from the mains to the heater or heater assembly power before any attempts are made to replace the emitter Contact your distributor for the correct repl...

Страница 14: ...flector up and away from the heater Repeat at the opposite end to remove other side reflector 8 The emitter wires should be pulled out of the side slots Fig U and the emitter can be lifted up completely The wires can then be gently pulled forward so that they come out from behind the reflector SCREW Fig U 5 Pull the emitter wires one at a time through the plate to remove as shown in Fig R Fig Q Fi...

Страница 15: ...r screws Before any other parts are fitted to make sure emitter is held safely Fig V W AL L M O U N T E D C O N F I G U R AT I O N S AT A G L AN C E 1 x Alpha H1 Unit 2 x Alpha H1 Units 3 x Alpha H1 Units 9 The emitter can now be removed away from the heater leaving it ready to have the new emitter fitted as shown in Fig V 15 ...

Страница 16: ...its INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Ontario L4Z 2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com Due to our policy of ongoing improvement we reserve the right to make changes without notice 2013 INFORESIGHT CONSUMER PRODUCTS INC Ref No 042224 Issue No 3 247748 ...