Fault Correction Procedure
283
INCOMPAT E-NET
Yes
Incompatible ethernet
interface card is
installed.
Install a compatible
ethernet interface card to
the printer then reboot. If
this message still appears,
contact your InfoPrint
service representative.
INTAKE FAN FAULT
Yes
Sensors cannot
detect current in fan
circuit.
See description for HMR
BANK FAN FLT.
INTERRUPT UNUSED
VECTOR 00
No
The controller board
receives an interrupt it
does not understand.
Cycle power. If this
message occurred once
and never again, you can
ignore it. If the message
reappears or appears
consistently, contact your
InfoPrint service
representative.
LOADING PROGRAM FROM
PORT XX%
N/A
The new emulation
program is loading
into printer RAM.
XX% indicates how
much of the program
has loaded.
No action required.
LOADING PROGRAM
INTO FLASH
N/A
The printer has
deleted the previous
program from flash
memory and is
loading the new
program into flash
memory.
No action required.
NOT READY
N/A
Printer state
message: printer is
offline, not in
communication with
host.
No action required.
ONLINE
CU TIMED OUT
No
Controller unit timed
out.
Contact your InfoPrint
service representative.
OPERATOR MENU
<first menu item>
N/A
Non–error status
message.
No action required.
OPERATOR MENU LOCKED
N/A
Non–error status
message.
No action required.
Table 9: Fault Messages
Fault Message
Operator
Correctable?
Explanation
Solution
Содержание 6500 Series
Страница 2: ......
Страница 6: ......
Страница 24: ...24 Chapter 1 Taking Care of Your Printer ...
Страница 56: ...56 Chapter 3 Changing the Power on Configuration ...
Страница 214: ...214 Chapter 4 Printer Information Menu ...
Страница 230: ...230 Chapter 5 IEEE 1284 Parallel Interface ...
Страница 304: ...304 Appendix B Printing Speed ...
Страница 310: ...310 Appendix C Compatibility and Limitations ...
Страница 334: ...334 Communication Statements ...
Страница 358: ...358 ...
Страница 359: ......
Страница 360: ...Printed in U S A S550 1335 03 07S550133503 ...