010 PARAMETER ERROR
No
Illegal parameter
value received in
command code over a
CT interface.
Contact your system
administrator.
011 SCS COMMAND ERROR
No
In CT emulation, the
printer received
undefined control
character (hex 40).
Contact your system
administrator.
012 STRUCTURED FLD
ERROR
No
Applications software
has violated
structured data field
parameters.
Contact your system
administrator.
013 ACTIVATE LOST
No
The printer detects a
twinax protocol
communication error
and reports the error.
Power off the printer.
014 INVALID ACTIVATE
No
Printer detects Twinax
protocol
communications error
and reports the error.
The printer reports the
error.
015 COMMUNICATION
CHECK
CHECK CABLE
Yes
Communication
check: a message
that appears in the CT
emulation indicating
that the line is not
active on a Twinax
interface.
Check cable connection.
016 INVALID COMMAND
No
Printer detects Twinax
protocol
communications error
and reports the error.
The printer reports the
error; host action is
required.
017 STACKER JAM
Yes
Paper is jammed in
the power stacker
area.
1. Open the cabinet rear
door and check for
obstructions preventing
elevator movement.
Remove any obstructions.
2. Run the print job again.
If the message reappears,
contact your InfoPrint
service representative.
Table 9: Fault Messages
Fault Message
Operator
Correctable?
Explanation
Solution
Содержание 6500 Series
Страница 2: ......
Страница 6: ......
Страница 24: ...24 Chapter 1 Taking Care of Your Printer ...
Страница 56: ...56 Chapter 3 Changing the Power on Configuration ...
Страница 214: ...214 Chapter 4 Printer Information Menu ...
Страница 230: ...230 Chapter 5 IEEE 1284 Parallel Interface ...
Страница 304: ...304 Appendix B Printing Speed ...
Страница 310: ...310 Appendix C Compatibility and Limitations ...
Страница 334: ...334 Communication Statements ...
Страница 358: ...358 ...
Страница 359: ......
Страница 360: ...Printed in U S A S550 1335 03 07S550133503 ...