Infopia Element Plus Скачать руководство пользователя страница 6

12/ 13

Before Testing

Be sure to read this section and the test strip package insert found in the 
test strip box carefully. You will need to have all of the necessary items to 
begin testing:

If the meter is moved from one temperature to another, allow 30 minutes 
for the meter to adjust to the new temperature before testing.
Make sure that the Element

TM  

Plus

 

meter and test strips have adjusted to 

the temperature of the location from where you are testing. 

Do not operate the Element

TM  

Plus system in direct sunlight.

1. Element

TM

 Plus meter

2. Element

TM

 Brand test strip

3. Lancing device
4. Sterile lancet 

Comparing your meter and laboratory results

Call toll free :

 1-888-446-3246

www.infopiausa.com

Test results with the Element

TM

 Plus blood glucose monitor are plasma-

equivalent. This method will help you and your healthcare professional 
compare your meter results with laboratory test results. The Element

TM

 

Plus test result and laboratory test results both are expressed in plasma-
equivalent units. However, your glucose monitor result may differ from 
your laboratory result due to normal variation. Your glucose monitor 
results can be affected by factors and conditions that do not affect labora-
tory results in the same way.

Your Element

TM

 Plus monitor value is considered accurate when it is 

within  ± 20%  of the laboratory measurement. There are some specific 
situations that could cause a difference of more than ± 20%. 

1. You are severely dehydrated.

2. You have eaten recently. The blood glucose level from blood
    obtained from a fingertip can be up to 70mg/dL higher than 
    blood drawn from a vein (venous sample) used for a lab test.

1     

3. Your hematocrit  is above 60% or below 20%.

1

 Sacks, D.B.: Carbohydrates.: “ Carbohydrates.” Burits, C.A. and Ashwood, E.R. (ed.), Tietz 

Textbook of Clinical Chemistry. Philadelphia: W.B. Saunders Company (1994), 959

Necessary items:

WARNING!
To reduce the chance of infection:

1. The lancing device and sterile lancets should NOT be shared with others.
2. Always use a new, sterile lancet and a new blood glucose test strip.
3. Practice using the Lancing Device and become accustomed with its use.
4. Lancets and blood glucose test strips are for single use only.
5. Wash your hands with warm clean water and soap before testing.
6. Avoid getting hand lotion, oils, dirt or debris on the lancets or on the 
    lancing device.
7. Dry your hands completely before testing.

Содержание Element Plus

Страница 1: ...IMM20 526 Rev 2012 07 02 Catalog number INFM21FUS TEL 1 888 446 3246 Blood Glucose Monitoring System Voice Feature in English Spanish...

Страница 2: ...and should not be shared The ElementTM Plus Blood Glucose Monitoring System is intended for self testing outside the body in vitro diagnostic use by people with diabetes at home as an aid in the manag...

Страница 3: ...g Administration FDA have become increasingly concerned about the risks for transmitting hepatitis B virus HBV and other blood borne pathogens to people undergoing finger stick procedures for blood sa...

Страница 4: ...Insert the Element Brand test strip Test Strip Ejector Releases and discards the test strip Display Screen Displays your test results symbols and messages Power Enter Button Powers the meter on off pr...

Страница 5: ...oving any test strips from the vial 4 Make a note of the discard date which is three months from the date you first open a new vial of strips Throw Element Brand test strips and vial away after the di...

Страница 6: ...e to normal variation Your glucose monitor results can be affected by factors and conditions that do not affect labora tory results in the same way Your ElementTM Plus monitor value is considered accu...

Страница 7: ...two hours before you test your blood Perform a control solution test to make sure the meter is working properly Take your meter with you to the lab While at the lab Follow all instructions in this own...

Страница 8: ...e time will be blinking Press and release either the or button to change the hour and minutes then press and release Setting Your Meter Select voice volume Select activities meal flag Select year mont...

Страница 9: ...red and downloaded properly Setting Your Meter Press and release either the or button to set the number of days to be calculated for that average That number will be blinking next to a at the bottom P...

Страница 10: ...the strip bottle The Element Plus automatically adjusts the meter accordingly Scroll through the icons with the or button until the control solution bottle is blinking press Press and release either...

Страница 11: ...om temperature 68 77 20 25 before testing Check the expiration date before performing a glucose control solution test Do not used if expired Once opened solution expires after 3 months If your control...

Страница 12: ...careful not to bend the test strip when inserting it into the port For a more accurate test result avoid testing under direct sunlight Warning Element Plus meter and reusable lancing device are for s...

Страница 13: ...tically count down Step 3 Warning You may get an inaccurate result if the blood sample is not completely filled Completely filled Insufficient amount of blood Correct Incorrect Pull the end of the lan...

Страница 14: ...e cover Pull the lancet out and discard accordingly Performing Your Test Step 4 The meter should begin counting down from 3 to 1 on the LCD display The LCD window will display the result of your blood...

Страница 15: ...g your averages Reviewing Your Results The ElementTM Plus meter stores up to 365 test results in its built in memory Test results and blood sugar averages can be retrieved any time Previous result Pre...

Страница 16: ...entTM Plus meter You may test your blood sugar from your forearm upper arm palm ventral palm or dorsal hand fingertips thigh or calf It is recommended that alternate site testing be used when sugars a...

Страница 17: ...Alternate Site Testing Lancing and sampling from an alternate site area Sampling from your upperarm forearm dorsal hand ventral palm thigh or calf allows you to use your fingertips less often You may...

Страница 18: ...cap to the highest setting 5 Hold the clear cap down against a fleshy area on the alternate site Press the release button Do not lift up Alternate Site Testing To ensure accurate results when lancing...

Страница 19: ...one including other family members Alternate Site Testing 5 While holding the lancing device on your test site look through the clear cap until a round drop of blood appears approximately 0 3 6 Lift t...

Страница 20: ...ng and Disinfecting your Element Plus system Materials Needed Cleaning and disinfecting can be completed by CaviWipesXL Disinfecting Towelettes EPA reg 46781 8 which is a commercially available EPA re...

Страница 21: ...cting towelettes in total To achieve disinfection of all the stated efficacy kill claims the meter lancing device should remain visibly wet for two minutes right after the completion of each treatment...

Страница 22: ...ds thoroughly with soap and water after handling the lancing device or test strips Be sure to clean and disinfect your lancing device when you get dirt blood or any type of liquid on it It also should...

Страница 23: ...Store your test strips in their original vial only Do not transfer to other container Store test strip packages in a cool and dry place Keep away from direct sunlight and heat After removing a test st...

Страница 24: ...line batteries should be used After changing the batteries please be sure to recheck your meter settings Call toll free 1 888 446 3246 www infopiausa com Transferring your results You can transfer tes...

Страница 25: ...eter Please re test with a new test strip Please re test with a new test strip Please re test with a new test strip Wet or used strip Damaged strip Applied blood before the ready for blood icon Action...

Страница 26: ...applying blood sample There is no sound on the voice option Please insert a new test strip and perform your test again Refer to performing a blood test p 23 Please check the voice volume setting If th...

Страница 27: ...e before returning your meter for any reason You will be given the information needed to get your problem handled correctly and efficiently Have your meter test strips and control solution nearby when...

Страница 28: ...56 57 Call toll free 1 888 446 3246 www infopiausa com MEMO Specifications 2 3 98 in 55 82 25mm 3V Alkaline Battery AAA X 2 2 4 oz 69g with batteries...

Отзывы: