Infopia Element Plus Скачать руководство пользователя страница 3

Warning:

• Element™ Plus meter and reusable lancing device are for single patient use 

only. Do not share them with anyone including other family members! Do 
not use on multiple patients!

• All parts of the kit are considered biohazardous and can potentially transmit 

infectious diseases, even after you have performed cleaning and disinfec-
tion.

• Always use a new, sterile lancet. Lancets are for single use only.
• Avoiding getting hands lotions, oil, dirt or debris in or on the lancets and 

reusable lancing device.

• Please refer to page 40-45 for cleaning and disinfecting Element™ Plus 

system.

“FDA Public Health Notification: Use of Fingerstick Devices on More 
than One Person Poses Risk for Transmitting Blood borne Pathogens 
:lnitial Communication”(2010) http://www.fda.gov/MedicalDevices/ 
“CDC Clinical Reminder: Use of Fingerstick Devices on More than One 
Person Poses Risk for Transmitting Blood borne Pathogens” (2010) 
http://www.cdc.gov/injectionsafey/Fingerstick-DevicesBGM.htm 

Important Safety Instructions

The Centers for Disease Control and Prevention(CDC) and the US Food 
and Drug Administration (FDA) have become increasingly concerned 
about the risks for transmitting hepatitis B virus (HBV) and other blood 
borne pathogens to people undergoing finger stick procedures for blood 
sample. For instance, people with diabetes who require assistance 
monitoring their blood glucose levels. 
Reports of HBV infection outbreaks linked to diabetes care have been 
increasing. This notice serves as a reminder that finger stick devices 
should never be used for more than one person.

Call toll free :

 1-888-446-3246

6 / 7

www.infopiausa.com

About your new Element™ Plus system: 

  Element™ Plus KIT contents 
  Element™ Plus meter
  Element™ Brand test strips

Before you test:

  Comparing your meter and laboratory results
  Setting the meter
  Performing a control solution test

Performing your test:

  Performing a blood test with your fingertip
  Disposing of your test strips and lancets 

Reviewing your results:

  Reviewing your blood sugar
  Reviewing your averages

Alternate site test:

  Performing a blood test with an alternate site

Caring for your Element™ Plus meter:

  Cleaning and Disinfecting your system
  Storage of your system
  Transferring your results
  Battery installation
  Troubleshooting
  Warranty
  Specifications

8
9

11

13
15
20

23
29

30
31

32

40
46
48
49
50
55
56

Table of contents

Содержание Element Plus

Страница 1: ...IMM20 526 Rev 2012 07 02 Catalog number INFM21FUS TEL 1 888 446 3246 Blood Glucose Monitoring System Voice Feature in English Spanish...

Страница 2: ...and should not be shared The ElementTM Plus Blood Glucose Monitoring System is intended for self testing outside the body in vitro diagnostic use by people with diabetes at home as an aid in the manag...

Страница 3: ...g Administration FDA have become increasingly concerned about the risks for transmitting hepatitis B virus HBV and other blood borne pathogens to people undergoing finger stick procedures for blood sa...

Страница 4: ...Insert the Element Brand test strip Test Strip Ejector Releases and discards the test strip Display Screen Displays your test results symbols and messages Power Enter Button Powers the meter on off pr...

Страница 5: ...oving any test strips from the vial 4 Make a note of the discard date which is three months from the date you first open a new vial of strips Throw Element Brand test strips and vial away after the di...

Страница 6: ...e to normal variation Your glucose monitor results can be affected by factors and conditions that do not affect labora tory results in the same way Your ElementTM Plus monitor value is considered accu...

Страница 7: ...two hours before you test your blood Perform a control solution test to make sure the meter is working properly Take your meter with you to the lab While at the lab Follow all instructions in this own...

Страница 8: ...e time will be blinking Press and release either the or button to change the hour and minutes then press and release Setting Your Meter Select voice volume Select activities meal flag Select year mont...

Страница 9: ...red and downloaded properly Setting Your Meter Press and release either the or button to set the number of days to be calculated for that average That number will be blinking next to a at the bottom P...

Страница 10: ...the strip bottle The Element Plus automatically adjusts the meter accordingly Scroll through the icons with the or button until the control solution bottle is blinking press Press and release either...

Страница 11: ...om temperature 68 77 20 25 before testing Check the expiration date before performing a glucose control solution test Do not used if expired Once opened solution expires after 3 months If your control...

Страница 12: ...careful not to bend the test strip when inserting it into the port For a more accurate test result avoid testing under direct sunlight Warning Element Plus meter and reusable lancing device are for s...

Страница 13: ...tically count down Step 3 Warning You may get an inaccurate result if the blood sample is not completely filled Completely filled Insufficient amount of blood Correct Incorrect Pull the end of the lan...

Страница 14: ...e cover Pull the lancet out and discard accordingly Performing Your Test Step 4 The meter should begin counting down from 3 to 1 on the LCD display The LCD window will display the result of your blood...

Страница 15: ...g your averages Reviewing Your Results The ElementTM Plus meter stores up to 365 test results in its built in memory Test results and blood sugar averages can be retrieved any time Previous result Pre...

Страница 16: ...entTM Plus meter You may test your blood sugar from your forearm upper arm palm ventral palm or dorsal hand fingertips thigh or calf It is recommended that alternate site testing be used when sugars a...

Страница 17: ...Alternate Site Testing Lancing and sampling from an alternate site area Sampling from your upperarm forearm dorsal hand ventral palm thigh or calf allows you to use your fingertips less often You may...

Страница 18: ...cap to the highest setting 5 Hold the clear cap down against a fleshy area on the alternate site Press the release button Do not lift up Alternate Site Testing To ensure accurate results when lancing...

Страница 19: ...one including other family members Alternate Site Testing 5 While holding the lancing device on your test site look through the clear cap until a round drop of blood appears approximately 0 3 6 Lift t...

Страница 20: ...ng and Disinfecting your Element Plus system Materials Needed Cleaning and disinfecting can be completed by CaviWipesXL Disinfecting Towelettes EPA reg 46781 8 which is a commercially available EPA re...

Страница 21: ...cting towelettes in total To achieve disinfection of all the stated efficacy kill claims the meter lancing device should remain visibly wet for two minutes right after the completion of each treatment...

Страница 22: ...ds thoroughly with soap and water after handling the lancing device or test strips Be sure to clean and disinfect your lancing device when you get dirt blood or any type of liquid on it It also should...

Страница 23: ...Store your test strips in their original vial only Do not transfer to other container Store test strip packages in a cool and dry place Keep away from direct sunlight and heat After removing a test st...

Страница 24: ...line batteries should be used After changing the batteries please be sure to recheck your meter settings Call toll free 1 888 446 3246 www infopiausa com Transferring your results You can transfer tes...

Страница 25: ...eter Please re test with a new test strip Please re test with a new test strip Please re test with a new test strip Wet or used strip Damaged strip Applied blood before the ready for blood icon Action...

Страница 26: ...applying blood sample There is no sound on the voice option Please insert a new test strip and perform your test again Refer to performing a blood test p 23 Please check the voice volume setting If th...

Страница 27: ...e before returning your meter for any reason You will be given the information needed to get your problem handled correctly and efficiently Have your meter test strips and control solution nearby when...

Страница 28: ...56 57 Call toll free 1 888 446 3246 www infopiausa com MEMO Specifications 2 3 98 in 55 82 25mm 3V Alkaline Battery AAA X 2 2 4 oz 69g with batteries...

Отзывы: