IN3138HD User’s Manual
–
58
–
No
Function
Command RW
Min Max Default
Step
Parameter
16V Color
Temp
TMP
RW 0
2
Source
Specific
1
Valid only when Display
Mode = User
0:Warm
1:Normal
2:Cold
17V Contrast
CON
RW 0 100
50
1
Valid only when Display
Mode = User
18V Current
Source
SRC
RW 0 13
0
1
0:VGA1
1:VGA2
5:HDMI-1
7:DP
12:Video
13:S-Video
21V Digital
Zoom
DZM
RW -10
10
0
1 -10~10
27V Error
Condition
ERR
R
n/a
n/a
n/a
n/a
0:No error
1:Lamp not lit after 5 At-
tempts
3:Lamp went out unexpect-
edly
4:Fan failure
5:
Overheating
7: Case open
8:DMD error
9:Color wheel
28V Factory
Reset
RST
W n/a
1
1
1 1:reset
32V Freeze
Screen
FRZ
RW 0
1
0
1 0:Disable
34V Gamma
GTB
RW 0
5
Source
Specific
1
Valid only when Display
Mode = User
0:1.8
1:2.0
2:2.2
3:2.4
4:B&W
5:Linear
40V Horz.
Position
HPS
RW -5 5
0
1
RGB source only
(HPS?) to get range
45V
Lamp Hours in High
Power Mode
LMO R
0
9999
Displays the number of
hours that the current lamp
has run in High Power
(Normal) mode.
46V
Lamp Hours in Low
Power Mode
LME R
0
9999
Displays the number of
hours that the current lamp
has run in Low Power (Eco)
mode.
47V Lamp
Life
LIF
R
n/a
Note
280W lamp life
3000 on
E20.8
49V
Lamp Resets (Total
number)
LMR R
0
9999
0 1
62V Lamp Low Power
IPM
RW
0
1
0
1
0=ECO, 1=Normal