Copyright ©2018, Infoblox, Inc.All right reserved.
Component
Description
Alarm LED
The alarm LED is dark when the power is off, or when the system is rebooting or running. It turns amber when at least one of
the services is not functioning. For more information, see
.
Table 2
Power/Status
LED
The Power/Status LED turns blue when the appliance is powered on. It is dark when the power is off. For more information, see
.
Table 2
Fan Vent
A fan vent to help maintain optimum operating temperature. Do not obstruct.
On/Off
Switch
A power switch to turn the power supply on and off. The switch is hidden. You can use a small blunt object, such as a paper
clip, to gently push the switch.
Table 2 Power / Status and Alarm LED Status
Power/Status
LED
Alarm
LED
Description
Corrective Action
Dark
Dark
The power is off
Plug in the power cable.
If the Power/Status LED is still dark, contact Infoblox
Technical Support.
Flashing Blue
Dark
The appliance is starting up.
Wait until the Power/Status LED turns solid blue.
Blue
Dark
The appliance has successfully started up and is running properly.
N/A
Blue
Flashing
Amber
The network is functional, but at least one of the services is not
functioning properly.
Check the status of the services through the Infoblox
GUI.
Blue
Flashing
Amber
A product startup failure may have occurred.
Perform a factory reset or contact Infoblox Technical
Support.
Blue
Flashing
Amber
A network failure has occurred. The appliance cannot connect to
the gateway.
Check network connectivity or contact Infoblox Technical
Support.
Trinzic 100 Appliance Rear Panel
Figure 2
shows the rear panel components on the Trinzic 100. For explanations of the Ethernet port LEDs, and console and Ethernet port
connector pin assignments, see
and
.
Ethernet Port LEDs
Interface Connector Pin Assignments
Figure 2 Trinzic 100 Appliance, Rear View
Table 3 Trinzic 100 Rear Panel Components
Component
Description