background image

Copyright ©2018, Infoblox, Inc.All right reserved.

1.  

2.  

3.  

NOTICE: All HA configuration is performed from the Grid Manager. This interface

is used only to configure a standalone node or to join a Grid.

Enter IP address: LAN1 Port IP address

Enter netmask: [Default: 255.255.255.0]: netmask

Enter gateway address [Default: n.n.n.1]: gateway IP address

Become Grid member? (y or n): n

After you confirm your network settings, the appliance automatically restarts.

Auto Provisioning NIOS Appliances

In addition to using the Grid Setup Wizard or accessing the Join Grid dialog box to join appliances to a Grid, you can set up an Infoblox appliance
using the auto provision feature, which allows a DHCP server to automatically assign an IP address to the appliance. You can then join the
auto-provisioned appliance to a Grid. 

Note: The Infoblox 4000 Series appliances support auto-provisioning, and enable it by default. vNIOS appliances do not support
auto-configuration.

When you connect the appliance to the network, a lease request is automatically sent to the DHCP server. The DHCP server fingerprints the
client as "Infoblox Appliance", as the DHCP client provides the unique option sequence (1,28,2,2,3,3,15,6,12) and vendor ID (INFOBLOX). The
DHCP server assigns a DHCP lease and a dynamic IP address to the appliance. If the DHCP lease request fails, the default IP address is
assigned to the appliance. The DHCP client tries to send the lease request for a duration of one minute when the appliance is either in the factory
default state or in the auto-configured default IP address state after a reboot.
If you do not use auto-provisioning to set up the appliance, then you can wait one minute before connecting the appliance to the network.
Otherwise, the DHCP server will assign a dynamic IP address to the appliance. Note that if you have already set the IP address for the appliance
through the NIOS CLI, Grid Manager, or API, then auto-provisioning is disabled for the appliance and the lease address is not requested. When
auto-provisioning is enabled for an appliance, the DNS, DHCP, FTP, TFTP, HTTP, NTP, bloxTools, Captive Portal, Reporting services, as well as
backup and restore are disabled for the member until a static IP address is set for the appliance. You can join a single appliance or HA pair to the
Grid. After the appliance joins the Grid, the static IP address is set for the appliance.
Complete the following to set up an appliance using auto-provisioning and to join the auto-provisioned appliance to the Grid Master:

Connect the appliance to a network by using an Ethernet cable. For information about cabling the appliance to a network, refer to 

Cabling

 

   

.

the Appliance to a Network

Connect the appliance to a power source and turn on the power. For information about powering the appliance, refer to 

Powering On the

 

Infoblox 4000 Series Appliance

The appliance automatically sends a lease request to the DHCP server, which assigns a DHCP lease and a dynamic IP address to the
appliance. The DHCP client tries to send the lease request for a duration of one minute and if the request fails, the default IP address
(192.168.1.2) is assigned to the appliance.
Join the appliance to the Grid Master. For information about joining an appliance to the Grid Master, refer to the 

 

 

NIOS Administrator Guid

e
A static IP address is set and auto-provisioning is automatically disabled for the appliance after it joins the Grid. If the Grid member fails
to join the Grid, then the remote console is enabled for the appliance and you can join the appliance to the Grid through the remote
console. You can login to the remote console using the user name 

, and the Grid shared secret as the password.

admin

Note: When auto-provisioning is disabled for an appliance and the network address is not preserved, auto-provisioning will be re-enabled and a
DHCP lease request is sent to the DHCP server if you reset the appliance using the CLI command 

 or reset the database using the

reset all

CLI command 

. However, if the static IP address for an appliance is set and network settings are preserved, auto-provisioning

reset database

will be re-enabled for the appliance but the lease address will not be requested if you reset the database using the CLI command 

reset

.

database

Specifying Appliance Settings

After the initial HTTPS connection to the Infoblox appliance, the Setup Wizard guides you through the basic deployment of the appliance on the
network.
You can deploy an appliance individually or in an HA (high availability) pair, for hardware redundancy. A single appliance or an HA pair without a
Grid license runs independently from a Grid. A Grid is a group of two or more Infoblox appliances that share sections of a common, distributed,
built-in database and which you configure and monitor through a single, secure point of access — the Grid master. To set up a Grid, you
configure a single or HA Grid master and at least one Grid member, which can also be a single appliance or an HA pair.
The following instructions Guide you through the wizard and include worksheets where you can note your appliance and network settings. After
you complete the wizard, you can set additional operational parameters and configure the appliance to provide services, such as DNS and DHCP.
For detailed instructions on configuring network services on the appliance, refer to the 

.

NIOS Administrator Guide

Содержание IB-4010

Страница 1: ...Infoblox Installation Guide 4000 Series Appliances Infoblox IB 4010 and Infoblox IB 4020 Advanced Appliance PT 4000 Network Insight ND 4000 Trinzic Reporting TR 4000 ...

Страница 2: ...es Rack Installation 13 2 3 Powering On the Infoblox 4000 Series Appliance 15 2 4 Cabling the Appliance to a Network 15 3 Accessing the Infoblox 4000 Series Appliance 16 3 1 Connecting to the Appliance 17 3 2 Auto Provisioning NIOS Appliances 18 3 3 Specifying Appliance Settings 18 3 4 Infoblox NIOS CLI 20 4 Infoblox 4000 Series Field Replaceable Units 20 4 1 Managing the Infoblox 4000 Series Disk...

Страница 3: ...in either capacity with a second IB 4010 appliance in high availability HA mode You configure and manage the IB 4010 appliance through the Grid Manager Note The IB 4010 appliance is currently sold in a Rev 2 hardware platform Infoblox supports a previous platform version Rev 1 only with field replaceable units FRUs and warranty replacements Current Rev 2 platform FRUs such as power supplies and fa...

Страница 4: ... Hot swappable AC or DC power supplies in a redundant 1 1 configuration Alternative system configurations for the support of copper or fiber SFP 10GbE interfaces with support for mixed copper fiber deployments and mixed 1GbE and 10GbE deployment based on installed transceivers Network Insight ND 4000 Product Overview The Network Insight ND 4000 is a high performance network appliance that supports...

Страница 5: ...f you wish to run the Infoblox 4000 Series in a NEBS 3 configuration remove the front panel of the appliance as shown in for DC Figure 2 only Figure 1 Infoblox 4000 Series Front View Appliance Front Panel Removing the front panel cover reveals front panel components including the hard disk drives and indicator lights illustrated in and Figure 2 described in For explanations of Ethernet port LEDs a...

Страница 6: ... that goes around the Fault UID LED to indicate read write activity status of the disk drive VGA Port The VGA port is not supported Use the console port or LAN1 port for initial setup Disk Drive Front Panel LEDs Disk drives are located on the appliance front panel To the right of each drive two LEDs display connection and activity status lists the Table 2 disk drive LED combinations and the states...

Страница 7: ...nsceivers in the LAN1 and LAN2 ports for an Infoblox 4010 appliance and installing 1GbE SFP copper transceivers in the MGMT and HA interfaces Note For ND 4000 and TR 4000 appliance models configured with 1GbE SFP or 10GbE SFP interfaces the HA port is reserved for future use and otherwise unused Order of ports from left to right is otherwise identical See the section for specific information on pa...

Страница 8: ...gnments follow IEEE 802 3 specifications All Infoblox Ethernet ports are auto sensing and automatically adjust to standard straight through and cross over Ethernet cables SFP SFP Ports The Infoblox 4000 series appliances ship with three or with four 4 SFP or SFP transceivers depending on the appliance model and the ordered configuration Depending on the options you have selected Infoblox 4000 seri...

Страница 9: ...to 70 C Single 3 3V power supply Maximum link length of 10km Uncooled 1310nm DFB laser Receiver limiting electrical interface Duplex LC connector Infoblox SFP Short Range 10GbE SR fiber Transceiver Infoblox part number IB SFPPLUS SR Hot pluggable SFP footprint Supports 9 95 to 10 5 Gb s bit rates Power dissipation 1W RoHS 6 compliant lead free Commercial temperature range 0 C to 70 C Single 3 3V p...

Страница 10: ...chassis for DC based 4000 Series systems see Ground Lug Installation DC of this guide Systems Only Figure 7 Infoblox 4000 Series Rear View with Four SFP Interfaces shows the rear view of the Infoblox PT 4000 10GE appliance Figure 8 Figure 8 Infoblox PT 4000 10GE appliance Rear View with Four SFP SFP Interfaces ...

Страница 11: ... reserved for future use ND 4000 TR 4000 Reporting LAN2 Port LAN2 connects a NIOS appliance to the network LAN2 is disabled by default You enable the LAN2 port and define its use through the Grid Manager after the initial setup Console Port A male DB 9 serial port for a console connection to change basic configuration settings and view basic system functions through the CLI command line interface ...

Страница 12: ...table appliance Dimensions 3 44 H x 17 54 W x 27 5 D 8 75 cm H x 44 55 cm W x 69 85 cm D Weight Approximately 61 00 pounds 27 66 kg Ethernet Ports MGMT HA LAN1 LAN2 auto sensing 1000Base TX MGMT HA LAN1 LAN2 auto sensing 10000Base TX Environmental Specifications Operating Temperature 41 F 104 F 5 40C Storage Temperature 22 to 140 degrees F 30 to 60 degrees C Operating Relative Humidity 10 to 90 no...

Страница 13: ... Installation and Removal Guidelines After receiving a shipped Infoblox 4000 Series appliance with SFP or SFP support Infoblox recommends installing the transceivers into your appliance before turning power on to the system for the first time Pay heed to the interface configuration required for your appliance deployment when inserting your SFP SFP transceivers Should circumstances require you to s...

Страница 14: ...mechanisms will click indicating that you can safely withdraw the system from the rack without accidentally pulling it free 9 Snap the Infoblox 4000 Series appliance into place and fasten it to the rack using the retainer screws provided in the accessory kit For further information refer to the instructions shipped with the accessory kit 10 Pull down the retention levers on both sides of the appli...

Страница 15: ...nce can then operate on the other To power the appliance For each power supply connect a power cable between the power connector on the back of the appliance and a properly grounded and rated power circuit that meets the provisions of the current edition of the National Electrical Code or other wiring rules that apply to your location Make sure that the outlet is near the appliance and is easily a...

Страница 16: ...Base system at https supp ort infoblox com Trunking Disable EtherChannel Disable IGMP Snooping Disable Port Channeling Disable Speed and Duplex settings Match these settings on both the Infoblox appliance and switch Disable other dynamic and proprietary protocols that might interrupt the forwarding of packets Use the Grid Manager from a management system to access set up and administer the Infoblo...

Страница 17: ...68 Recommended 1280 x 1024 or better CLI Access Secure Socket Shell SSH client that supports SSHv2 Terminal emulation program such as Minicom or Hilgraeve Hyperterminal Grid Manager fully supports Microsoft Internet Explorer 11 x and 10 x when you enable compatibility view in the browser Features in the Repo tab may not function properly if you disable compatibility view In the browser go to to en...

Страница 18: ...ormation about cabling the appliance to a network refer to Cabling the Appliance to a Network Connect the appliance to a power source and turn on the power For information about powering the appliance refer to Powering On the Infoblox 4000 Series Appliance The appliance automatically sends a lease request to the DHCP server which assigns a DHCP lease and a dynamic IP address to the appliance The D...

Страница 19: ...es the FQDN fully qualified domain name of the appliance The process is straightforward For information about certificates refer to the N IOS Administrator Guide 3 Log in using the default user name and password and admin infoblox Note User names and passwords are case sensitive 4 Read the Infoblox End User License Agreement and click to proceed The Setup Wizard opens for defining basic network an...

Страница 20: ...pecified log file up to 10 previous logfiles will be preserved The two main groups of NIOS CLI commands are and To see the complete list of the set commands enter after the set show help set command prompt Likewise to see a complete list of the show commands enter For information about the CLI commands refer to help show the Infoblox CLI Guide Infoblox 4000 Series Field Replaceable Units The Infob...

Страница 21: ...ray In the event of a disk failure you must replace the failed disk with one that is qualified and shipped from Infoblox and has the same disk type as the rest of the disks in the array The appliance displays information about mismatched disks in the Description column in the panel The Infoblox 4000 Series Detailed Status appliances use only the disk type For the array to function properly all dis...

Страница 22: ...ld damage the array If you insert a replacement drive into a live array and the controller doesn t recognize the drive power down the appliance All disks in the RAID array must have the same disk type for the array to function properly In the unlikely event that two disk drives fail simultaneously and the appliance is still operational remove and replace the failed disk drives one at a time Rebuil...

Страница 23: ...outlet illustrates the process of replacing an AC power supply Figure 15 for the IInfoblox 4000 Series Figure 15 Removing an Infoblox 4000 Series AC Power Supply To replace an Infoblox 4000 Series AC power supply do the following Turn off the power supply Disconnect the AC power cable from the power outlet Gently push back the red catch release lever grip the power supply handle and pull the power...

Страница 24: ...n see Ground Lug Installation DC Systems Only Important Retain your original AC power supplies for possible future RMAs When you remove the AC power supplies for new DC power supplies ensure that you keep the original AC power supplies in a safe plac e for use in RMA situations For appliance RMAs you must replace the DC power supplies in the appliance with its original AC power supplies RMA shipme...

Страница 25: ...ed spinning and must be replaced 6 Figure 18 shows a four fan module configuration The system fans can be removed from their installation base and replaced A pair of small handles reside on the top of each fan module which you grasp with fingertips when pulling the unit out of the system Pay attention to unit alignment and placement before removing from the system Figure 18 System fan removal pull...

Страница 26: ...ries DC PSU Rev 2 IB 4000 R2 PSU DC FRU only Y Y Y Y Infoblox IB Type 3 Disk Assembly Rev 2 IB 4000 R2 DISK HDD300 FRU only Y Y Y Y Infoblox IB 4000 Series fan set Rev 2 IB 4000 R2 FAN FRU only Y Y Y Y Infoblox IB 4000 Series 14AWG AC Power Cord IB POWER CORD 4K Contact Infoblox Support Y Y Y Y Infoblox 4000 Series SFP SFP Transceivers Infoblox offers SFP SFP transceivers of various types for 1GbE...

Страница 27: ...able 12 Infoblox 4000 Series International AC Power Cords Infoblox Part Number International Item Description IB POWER CORD 4K AUS Power Cord Infoblox 4000 series Australia IB POWER CORD 4K BR Power Cord Infoblox 4000 series Brazil IB POWER CORD 4K CL Power Cord Infoblox 4000 series Chile Italy IB POWER CORD 4K CN Power Cord Infoblox 4000 series China IB POWER CORD 4K EU Power Cord Infoblox 4000 s...