20/22
The system page can set the EDID of HDMI
input source; In “General Setting”,
you can set the output screen’s brightness, contrast and color, select output
resolution, and enable/disable BEEP or HDBT POC.
This page can also be used for firmware upgrade, selecting boot screen,
factory reset and reboot operations.
■
Control Page
The control page allows users to control related devices in the conference
through the desktop plate, such as turning on/off the projector, projection
screen, curtain, light, air conditioner and other devices. Control methods
include serial port, relay interface, IR output control, CEC, etc.
1.
RS-232 Setting
•
3 sets of independent serial ports (2 sets for the transmitter end, 1 set for the
receiver end). The
serial port’s feature can be set separately.
•
You can set the Device Name, Baudrate, Databit, Parity and Stopbit.
•
You can select ASCII or HEX output.
2.
Relay Setting
6 sets of independent relay control function (4 sets for the transmitter end, 2 sets
for the receiver end). The default setting closing time is 30 seconds. The setting
range is 0 to 100 seconds.
Note:
When the time is set to 100 seconds, the relay will always be in the closing
state.