4. Specifications 

Model

 

Clip CH50 V2

 

Detector Parameters

 

Detector Type

 

Vox Uncooled

 

Resolution

 

640*512

 

Pixel Size

 

12um

 

NETD

 

≤40mk

 

Frame Rate

 

50Hz

 

Optics Parameters

 

Objective Lens

 

50mm

 

Field of View

 

8.8°×7.0°

 

Recommended magnification of the day 

sight

 

×1-×9

 

E-zoom

 

×1 / ×2 / ×4

 

Detection Range

 

(Target size: 1.7m×0.5m, P(n)=99%)

 

2597m

 

Display Parameters

 

Type

 

OLED

 

Resolution

 

1024×768

 

Electrical Parameters

 

Battery

 

CR123×2 / 16650×2

 

Max. Battery Life

 

4h / 7h

 

Power Consumption

 

1200mW

 

External Interface

 

USB Interface

 

Type-C

 

Video Output

 

PAL (RCA Port)

 

External Power

 

Type-C

 

Functions

 

Содержание Clip CH50 Series

Страница 1: ...shall not be copied and distributed in any form without written permission 11th Guiyang Street YEDA Yantai 264006 P R China 86 400 998 3088 1 Clip CH50 V2 Thermal Imaging Attachment User Manual V1 1...

Страница 2: ...10 6 1 Power on Power off 10 6 2 Standby Mode 10 6 3 Status bar 10 6 4 Navigation Menu 10 6 5 Advanced Menu 11 6 6 Calibration the sensor 13 6 7 Image Calibration 14 6 7 E Zoom center adjustment 15 6...

Страница 3: ...d distributed in any form without written permission 11th Guiyang Street YEDA Yantai 264006 P R China 86 400 998 3088 3 10 1 User Interface Description 24 10 2 Product Dimensions 24 10 2 1 Boundary Di...

Страница 4: ...mog and can detect the objects through obstacles such as branch tall grass dense bushes and so on Clip CH50 V2 has a wide range application including night hunting observation and terrain orientation...

Страница 5: ...e lens to make the image to be the clearest when the image is indistinct Power P Button Power on Power off Standby Up Left Menu M Button Entering menu Parameter switch Correction C Button Shutter corr...

Страница 6: ...ton Adjust parameter Scroll up options M 5 Button Enter the Menu Navigation Enter the advanced menu M 5 Button Function switch Parameter selection Save and exit menu C 6 Button Shutter Calibration Bac...

Страница 7: ...W White hot R Red hot C Pseudo Color Image Sharpness levels 1 4 E zoom Only for Monocular 1 2 4 Ultraclear mode Bluetooth option Bluetooth connected Video output option Video output is on Auto shutter...

Страница 8: ...40 512 Pixel Size 12um NETD 40mk Frame Rate 50Hz Optics Parameters Objective Lens 50mm Field of View 8 8 7 0 Recommended magnification of the day sight 1 9 E zoom 1 2 4 Detection Range Target size 1 7...

Страница 9: ...ction 12 m thermal imaging detector Detection range beyond 2 5km 1024 768 high resolution AMOLED display No rezeroing required and quick attached 48mm long focal length eyepiece E zoom with aiming acc...

Страница 10: ...button briefly for power saving 6 3 Status bar The status bar is located at the bottom of the screen which shows information such as image mode screen brightness E Zoom Reticle types Sharpness Bluetoo...

Страница 11: ...ration E zoom center adjustment bad pixel correction factory reset and return to the main menu can be selected Please referring to table 6 1 for details Fig 6 2 Advanced menu interface Operations In t...

Страница 12: ...ON OFF Transfer the analog video in PAL through the Type C data cable The icon displays at the status bar Auto shutter calibration ON OFF When this function is on the device can automatically perform...

Страница 13: ...exit Return Return to the main menu 6 6 Calibration the sensor When the image is degraded or uneven it can be improved by calibration Calibration enables the detector temperature background to be equ...

Страница 14: ...ght sight before mounting Clip CH50 V2 Installing Clip CH50 V2 on the day light sight and repeat the calibration steps above Then aiming at the target at 100 meters and shoot Measure the horizontal di...

Страница 15: ...ope s reticle Hold down M 5 button to save and exit the adjustment interface Aim the target with E Zoom observe if the center of E zoom overlap with reticle of day light scope Repeat previous center a...

Страница 16: ...button to exit the bad pixel correction Fig 6 5 Bad pixel correction interface 6 9 Compass Calibration In the home screen press and hold the P 4 and C 6 button at the same time to enter the compass c...

Страница 17: ...ce to an object of known size Fig 6 7 Stadiametric rangefinder interface In the home screen press and hold the P 4 and C 6 button for 3s at the same time to enter the stadiametric rangefinder interfac...

Страница 18: ...two measurement lines P 4 button is used to increase the distance and C 6 button to reduce the distance The distance to the target is automatically recalculated while moving the measurement lines and...

Страница 19: ...the device Refer to figure 7 1 and 7 2 for details 7 1 Bluetooth Remote Controller Install a CR2030 button battery purchased by yourself on the remote controller Turn on the Bluetooth of the device an...

Страница 20: ...phone Turn on the bluetooth of the device and the bluetooth icon will show at the bottom of the screen Open the APP select and connect with the device within 1 minute until the message connect device...

Страница 21: ...cover and press heavily until heard clicking sound and make sure the cover is closed on both sides correctly After installation please set the battery type in the advanced menu for the first starting...

Страница 22: ...be scrubbed with soft cloth by dipping certain amount of alcohol For optical glass devices such as eyepiece lens and objective lens dust should be blown first and then use charcoal pen or degreasing c...

Страница 23: ...ing Open analog video output Data cable doesn t support data transmission Replace data cable Fail to start up Wrong battery installation or low power Check the battery installation and battery power I...

Страница 24: ...06 P R China 86 400 998 3088 24 10 Appendix 10 1 User Interface Description Custom interface and data cable are adopted to support type c power supply serial port and PAL video Support type c and batt...

Страница 25: ...All rights reserved and shall not be copied and distributed in any form without written permission 11th Guiyang Street YEDA Yantai 264006 P R China 86 400 998 3088 25 10 2 2 Bottom Mounting Hole Size...

Отзывы: